Design and test validation of a novel low-cost quartz window for reducing heat losses in concentrating solar power applications

Concentrating Solar Power (CSP) continues to see increased deployment with nearly 5 GW of CSP installed worldwide. CSP is particularly attractive as a renewable energy source given that the storage and recovery of absorbed heat may be accomplished using sensible, latent, or thermochemical systems; t...

Full description

Saved in:
Bibliographic Details
Published inAIP conference proceedings Vol. 2126; no. 1
Main Authors Sullivan, Shaun D., Kesseli, James B.
Format Journal Article Conference Proceeding
LanguageEnglish
Published Melville American Institute of Physics 25.07.2019
Subjects
Online AccessGet full text

Cover

Loading…
Abstract Concentrating Solar Power (CSP) continues to see increased deployment with nearly 5 GW of CSP installed worldwide. CSP is particularly attractive as a renewable energy source given that the storage and recovery of absorbed heat may be accomplished using sensible, latent, or thermochemical systems; this enables cost-effective deferral and on-demand dispatch of electricity generated from CSP, addressing mismatches between power demand and solar availability. Power tower and dish-based CSP configurations, in which reflected solar energy is focused onto a single central target, can generate very high temperatures; this enables the use of supercritical steam cycles, air Brayton cycles, or supercritical carbon dioxide (sCO2) power cycles that produce electricity at higher efficiencies than can be achieved with photovoltaic (PV) or linear-focus trough-based CSP systems. Critical to the performance and economics of all CSP systems is their ability to retain as much of the captured solar energy as possible. Heat losses to the environment directly penalize the efficiency of the system, requiring additional collector area to achieve the target power. The receiver, through which solar energy is absorbed and conveyed as heat into a working fluid, is necessarily the highest-temperature component in the system; as a result it has the greatest potential to lose heat via radiation to the environment. Furthermore, convection losses from the high temperature absorber to the ambient environment may also be high. Historically quartz windows have been employed in conjunction with cavity-type receivers, which are suitable for dish- mounted and small-scale power tower applications. Quartz is naturally transparent to wavelengths of visible light but is opaque to a large fraction of infrared wavelengths. Consequently, concentrated solar energy passes through a quartz surface unimpeded, but a significant fraction of the infrared radiation that might otherwise be lost from the hot absorber surface to the environment is absorbed by the window; this provides a radiation shield and reduces heat losses. The window may also impede the formation of convection cells, further reducing heat losses. These benefits must be weighed against the penalties imposed by the inclusion of a quartz window. For example, for every window surface that incoming light passes through at greater than its critical angle, there is a 4% reflection loss; this corresponds to a total energy loss of 7.8% in the case of a standard planar window, accounting for reflection losses at both front and back faces. Therefore the window is only practical if reduces heat losses by at least this amount. Furthermore, the cost of incorporating a quartz windows can be prohibitive, particularly in larger sizes (corresponding to larger power ratings and/or non-cavity receivers), more complex forms designed to reduce reflection losses, and for systems in which the window must react elevated internal pressures. To address these shortcomings Brayton Energy has developed, analyzed, and tested a novel quartz tube window system. This configuration employs commodity-priced thin-walled quartz tubes with L/D ratios of 3 or more. These tubes are arrayed in a close-packed configuration and mounted over the receiver aperture. Incoming concentrated sunlight only encounters thin tube wall surfaces at an angle exceeding the critical angle; consequently, the fraction of the aperture that is subject to the 4% reflection loss is very small. All other surface encounters occur along the lateral surface of the tube walls at an incident angle below the critical angle, resulting in reflections that redirect the light deeper into the cavity as opposed to back out to environment. Depending upon the specific receiver and absorber element configuration, a quartz-tube window design may be also implemented such that it impedes convection cells; this can further reduce heat losses to the environment and improve overall system efficiency. The design, analysis, fabrication, installation, and performance testing of quartz tube windows for two different receiver configurations will be reported here. These studies indicate that for the receiver applications studied, inclusion of a quartz tube window has the potential to dramatically reduce the thermal losses at the design point. Validation testing was performed to directly measure heat loss from systems at operating temperatures appropriate for a sCO2 power block both with and without the quartz tube window in place. Inclusion of a quartz tube window to the cavity receiver decreased its design point heat loss by up to 33%, depending on the receiver tilt angle. The addition of a quartz tube window to an open receiver module decreased its combined radiative and convective heat losses by more than 50%.
AbstractList Concentrating Solar Power (CSP) continues to see increased deployment with nearly 5 GW of CSP installed worldwide. CSP is particularly attractive as a renewable energy source given that the storage and recovery of absorbed heat may be accomplished using sensible, latent, or thermochemical systems; this enables cost-effective deferral and on-demand dispatch of electricity generated from CSP, addressing mismatches between power demand and solar availability.Power tower and dish-based CSP configurations, in which reflected solar energy is focused onto a single central target, can generate very high temperatures; this enables the use of supercritical steam cycles, air Brayton cycles, or supercritical carbon dioxide (sCO2) power cycles that produce electricity at higher efficiencies than can be achieved with photovoltaic (PV) or linear-focus trough-based CSP systems. Critical to the performance and economics of all CSP systems is their ability to retain as much of the captured solar energy as possible. Heat losses to the environment directly penalize the efficiency of the system, requiring additional collector area to achieve the target power. The receiver, through which solar energy is absorbed and conveyed as heat into a working fluid, is necessarily the highest-temperature component in the system; as a result it has the greatest potential to lose heat via radiation to the environment. Furthermore, convection losses from the high temperature absorber to the ambient environment may also be high.Historically quartz windows have been employed in conjunction with cavity-type receivers, which are suitable for dish- mounted and small-scale power tower applications. Quartz is naturally transparent to wavelengths of visible light but is opaque to a large fraction of infrared wavelengths. Consequently, concentrated solar energy passes through a quartz surface unimpeded, but a significant fraction of the infrared radiation that might otherwise be lost from the hot absorber surface to the environment is absorbed by the window; this provides a radiation shield and reduces heat losses. The window may also impede the formation of convection cells, further reducing heat losses. These benefits must be weighed against the penalties imposed by the inclusion of a quartz window. For example, for every window surface that incoming light passes through at greater than its critical angle, there is a 4% reflection loss; this corresponds to a total energy loss of 7.8% in the case of a standard planar window, accounting for reflection losses at both front and back faces. Therefore the window is only practical if reduces heat losses by at least this amount. Furthermore, the cost of incorporating a quartz windows can be prohibitive, particularly in larger sizes (corresponding to larger power ratings and/or non-cavity receivers), more complex forms designed to reduce reflection losses, and for systems in which the window must react elevated internal pressures.To address these shortcomings Brayton Energy has developed, analyzed, and tested a novel quartz tube window system. This configuration employs commodity-priced thin-walled quartz tubes with L/D ratios of 3 or more. These tubes are arrayed in a close-packed configuration and mounted over the receiver aperture. Incoming concentrated sunlight only encounters thin tube wall surfaces at an angle exceeding the critical angle; consequently, the fraction of the aperture that is subject to the 4% reflection loss is very small. All other surface encounters occur along the lateral surface of the tube walls at an incident angle below the critical angle, resulting in reflections that redirect the light deeper into the cavity as opposed to back out to environment. Depending upon the specific receiver and absorber element configuration, a quartz-tube window design may be also implemented such that it impedes convection cells; this can further reduce heat losses to the environment and improve overall system efficiency.The design, analysis, fabrication, installation, and performance testing of quartz tube windows for two different receiver configurations will be reported here. These studies indicate that for the receiver applications studied, inclusion of a quartz tube window has the potential to dramatically reduce the thermal losses at the design point. Validation testing was performed to directly measure heat loss from systems at operating temperatures appropriate for a sCO2 power block both with and without the quartz tube window in place. Inclusion of a quartz tube window to the cavity receiver decreased its design point heat loss by up to 33%, depending on the receiver tilt angle. The addition of a quartz tube window to an open receiver module decreased its combined radiative and convective heat losses by more than 50%.
Concentrating Solar Power (CSP) continues to see increased deployment with nearly 5 GW of CSP installed worldwide. CSP is particularly attractive as a renewable energy source given that the storage and recovery of absorbed heat may be accomplished using sensible, latent, or thermochemical systems; this enables cost-effective deferral and on-demand dispatch of electricity generated from CSP, addressing mismatches between power demand and solar availability. Power tower and dish-based CSP configurations, in which reflected solar energy is focused onto a single central target, can generate very high temperatures; this enables the use of supercritical steam cycles, air Brayton cycles, or supercritical carbon dioxide (sCO2) power cycles that produce electricity at higher efficiencies than can be achieved with photovoltaic (PV) or linear-focus trough-based CSP systems. Critical to the performance and economics of all CSP systems is their ability to retain as much of the captured solar energy as possible. Heat losses to the environment directly penalize the efficiency of the system, requiring additional collector area to achieve the target power. The receiver, through which solar energy is absorbed and conveyed as heat into a working fluid, is necessarily the highest-temperature component in the system; as a result it has the greatest potential to lose heat via radiation to the environment. Furthermore, convection losses from the high temperature absorber to the ambient environment may also be high. Historically quartz windows have been employed in conjunction with cavity-type receivers, which are suitable for dish- mounted and small-scale power tower applications. Quartz is naturally transparent to wavelengths of visible light but is opaque to a large fraction of infrared wavelengths. Consequently, concentrated solar energy passes through a quartz surface unimpeded, but a significant fraction of the infrared radiation that might otherwise be lost from the hot absorber surface to the environment is absorbed by the window; this provides a radiation shield and reduces heat losses. The window may also impede the formation of convection cells, further reducing heat losses. These benefits must be weighed against the penalties imposed by the inclusion of a quartz window. For example, for every window surface that incoming light passes through at greater than its critical angle, there is a 4% reflection loss; this corresponds to a total energy loss of 7.8% in the case of a standard planar window, accounting for reflection losses at both front and back faces. Therefore the window is only practical if reduces heat losses by at least this amount. Furthermore, the cost of incorporating a quartz windows can be prohibitive, particularly in larger sizes (corresponding to larger power ratings and/or non-cavity receivers), more complex forms designed to reduce reflection losses, and for systems in which the window must react elevated internal pressures. To address these shortcomings Brayton Energy has developed, analyzed, and tested a novel quartz tube window system. This configuration employs commodity-priced thin-walled quartz tubes with L/D ratios of 3 or more. These tubes are arrayed in a close-packed configuration and mounted over the receiver aperture. Incoming concentrated sunlight only encounters thin tube wall surfaces at an angle exceeding the critical angle; consequently, the fraction of the aperture that is subject to the 4% reflection loss is very small. All other surface encounters occur along the lateral surface of the tube walls at an incident angle below the critical angle, resulting in reflections that redirect the light deeper into the cavity as opposed to back out to environment. Depending upon the specific receiver and absorber element configuration, a quartz-tube window design may be also implemented such that it impedes convection cells; this can further reduce heat losses to the environment and improve overall system efficiency. The design, analysis, fabrication, installation, and performance testing of quartz tube windows for two different receiver configurations will be reported here. These studies indicate that for the receiver applications studied, inclusion of a quartz tube window has the potential to dramatically reduce the thermal losses at the design point. Validation testing was performed to directly measure heat loss from systems at operating temperatures appropriate for a sCO2 power block both with and without the quartz tube window in place. Inclusion of a quartz tube window to the cavity receiver decreased its design point heat loss by up to 33%, depending on the receiver tilt angle. The addition of a quartz tube window to an open receiver module decreased its combined radiative and convective heat losses by more than 50%.
Author Kesseli, James B.
Sullivan, Shaun D.
Author_xml – sequence: 1
  givenname: Shaun D.
  surname: Sullivan
  fullname: Sullivan, Shaun D.
  organization: Principal Engineer, Renewable Energy R&D Program Manager; Brayton Energy, LLC
– sequence: 2
  givenname: James B.
  surname: Kesseli
  fullname: Kesseli, James B.
  email: kesseli@braytonenergy.com
  organization: President; Brayton Energy, LLC
BookMark eNp9kDtPwzAUhS0EEm1h4B9YYkNK8StOMqLylCqxgMRm3ThOcRXs1E4awcJfJ7SV2JjucD6dc-6ZomPnnUHogpI5JZJf03lKaZZm5AhNaJrSJJNUHqMJIYVImOBvp2ga45oQVmRZPkHftybalcPgKtyZ2OEtNLaCznqHfY0BO781DW78kGg_ypseQveFB-sqP-DaBxxM1WvrVvjdQDeCMZqIrcPaO21cF0avUYy-gYBbP5iAoW0bq3cZ8Qyd1NBEc364M_R6f_eyeEyWzw9Pi5tl0rI87xLONS1FJqQ0PGeCaiCEclloYgQQmWepICBqLQURdSkZcFlp0DUri6JkGvgMXe592-A3_fioWvs-uDFSMSaFEJRzOVJXeypq2-0KqjbYDwifihL1O7Ci6jDwf_DWhz9QtVXNfwAxqn-q
CODEN APCPCS
ContentType Journal Article
Conference Proceeding
Copyright Author(s)
2019 Author(s). Published by AIP Publishing.
Copyright_xml – notice: Author(s)
– notice: 2019 Author(s). Published by AIP Publishing.
DBID 8FD
H8D
L7M
DOI 10.1063/1.5117570
DatabaseName Technology Research Database
Aerospace Database
Advanced Technologies Database with Aerospace
DatabaseTitle Technology Research Database
Aerospace Database
Advanced Technologies Database with Aerospace
DatabaseTitleList Technology Research Database

DeliveryMethod fulltext_linktorsrc
Discipline Physics
EISSN 1551-7616
Editor Richter, Christoph
Editor_xml – sequence: 1
  givenname: Christoph
  surname: Richter
  fullname: Richter, Christoph
  organization: SolarPACES c/o Solarway SLNE
ExternalDocumentID acp
Genre Conference Proceeding
GroupedDBID -~X
23M
5GY
AAAAW
AABDS
AAEUA
AAPUP
AAYIH
ABJNI
ACBRY
ACZLF
ADCTM
AEJMO
AFATG
AFHCQ
AGKCL
AGLKD
AGMXG
AGTJO
AHSDT
AJJCW
ALEPV
ALMA_UNASSIGNED_HOLDINGS
ATXIE
AWQPM
BPZLN
F5P
FDOHQ
FFFMQ
HAM
M71
M73
RIP
RQS
SJN
~02
8FD
ABJGX
ADMLS
H8D
L7M
ID FETCH-LOGICAL-p288t-33c1b47466e38241ca001369c0e4a0687540a4fc6404fb62a36dcacf2b99b2ca3
ISSN 0094-243X
IngestDate Sun Jun 29 15:37:00 EDT 2025
Fri Jun 21 00:15:32 EDT 2024
Sat Jul 27 14:03:44 EDT 2019
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 1
Language English
License 0094-243X/2019/2126/030058/12/$30.00
Published by AIP Publishing.
LinkModel OpenURL
MeetingName SolarPACES 2018: International Conference on Concentrating Solar Power and Chemical Energy Systems
MergedId FETCHMERGED-LOGICAL-p288t-33c1b47466e38241ca001369c0e4a0687540a4fc6404fb62a36dcacf2b99b2ca3
Notes ObjectType-Conference Proceeding-1
SourceType-Conference Papers & Proceedings-1
content type line 21
OpenAccessLink https://aip.scitation.org/doi/pdf/10.1063/1.5117570
PQID 2264441336
PQPubID 2050672
PageCount 12
ParticipantIDs scitation_primary_10_1063_1_5117570
proquest_journals_2264441336
PublicationCentury 2000
PublicationDate 2019-07-25
PublicationDateYYYYMMDD 2019-07-25
PublicationDate_xml – month: 07
  year: 2019
  text: 2019-07-25
  day: 25
PublicationDecade 2010
PublicationPlace Melville
PublicationPlace_xml – name: Melville
PublicationTitle AIP conference proceedings
PublicationYear 2019
Publisher American Institute of Physics
Publisher_xml – name: American Institute of Physics
SSID ssj0029778
Score 2.2135978
Snippet Concentrating Solar Power (CSP) continues to see increased deployment with nearly 5 GW of CSP installed worldwide. CSP is particularly attractive as a...
SourceID proquest
scitation
SourceType Aggregation Database
Enrichment Source
Publisher
SubjectTerms Absorbers
Accounting
Alternative energy sources
Apertures
Carbon dioxide
Configuration management
Configurations
Convection cells
Critical angle
Economic conditions
Electricity consumption
Electricity pricing
Energy dissipation
Energy storage
Heat
Heat transfer
Infrared radiation
Operating temperature
Photovoltaic cells
Quartz
Receivers
Reflection
Solar cells
Solar energy
Tubes
Wavelengths
Working fluids
Title Design and test validation of a novel low-cost quartz window for reducing heat losses in concentrating solar power applications
URI http://dx.doi.org/10.1063/1.5117570
https://www.proquest.com/docview/2264441336
Volume 2126
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3fa9swEMfFljK2t_3oWNduCLY3o86WZFl-LGtLN9KusATyZmTZgkKxQ-I10Jf96z1J_pU1DLYXE4xiG31k3Z38vRNCn_NQ5kIJSRJKDeFFkZNU8ogUMlZlWEoWuTrdl1fiYs6_L-LFsFOhyy5p8mN9vzOv5H-owjngarNk_4Fsf1E4Ab-BLxyBMBwfM95pak6-XVvheFcsdmizHo-FUyfT8GJJsAIBPMNN0fuKKqjqu_I2uK03RNdrl2i5au6DDYTr9cbpEFe2wKtdVLBTNzS0X4oDp2CvvLrTiafXNkwOlnbftWD8YXy8suCSmYjPQh6J-VW1LVtwwlQ9XkiEAJFQ7nb1BYvSTqNxRBLhsyi7eRaMpPhzRD2awMFjsmsJx7EtIeq3FNkukn31IzufT6fZ7Gwxe4r2KEtkPEF7J6eX0599pA1OrTfB7aN1JaUE-9JfeiukeA7-hpc-jLyL2Uu0P-Rd4use4Sv0pKxeo2dtX7xBvz1HDByx5YgHjrg2WGHHEXccseeIPUcMHHHHEVuO2HPENxXe4ogdR-w44jHHfTQ_P5t9vSDtBhpkSaVsCGM6ynnChSiZBFdNK1eiL9VhyVUoIFTloeJGCx5ykwuqmCi00obmaZpTrdhbNKnqqnyHsJFJaqihmiYQBBRGyYTFrIQ_R4VJaX6AjrrezNo3ZJ3ZJG1wtxkTB-hT38PZ0tdRyZz-QbAsylokO1vd1auhRbYszPu_3-oQvRgG8xGaNKtf5QdwHJv8YztMHgAEpHcM
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=AIP+conference+proceedings&rft.atitle=Design+and+test+validation+of+a+novel+low-cost+quartz+window+for+reducing+heat+losses+in+concentrating+solar+power+applications&rft.date=2019-07-25&rft.pub=American+Institute+of+Physics&rft.issn=0094-243X&rft.eissn=1551-7616&rft.volume=2126&rft.issue=1&rft_id=info:doi/10.1063%2F1.5117570&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0094-243X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0094-243X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0094-243X&client=summon