Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index
Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. Low-radiation-dose multidetector CT was performed in 21 subjects representing a...
Saved in:
Published in | Academic radiology Vol. 17; no. 2; p. 146 |
---|---|
Main Authors | , , , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.02.2010
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement.
Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens.
The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03).
The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology. |
---|---|
AbstractList | Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement.
Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens.
The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03).
The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology. |
Author | Choong, Cliff K Pilgram, Thomas K Bierhals, Andrew J Bae, Kyongtae T Gierada, David S Patterson, G Alexander Woods, Jason C Ritter, Jon H Cooper, Joel D Das, Nitin A Hogg, James C Lutey, Barbara A Battafarano, Richard J Whiting, Bruce R Hong, Cheng Bartel, Seth T Meyers, Bryan F |
Author_xml | – sequence: 1 givenname: David S surname: Gierada fullname: Gierada, David S email: gieradad@wustl.edu organization: Mallinckrodt Institute of Radiology, 510 S. Kingshighway Blvd., Washington University, St. Louis, MO 63105, USA. gieradad@wustl.edu – sequence: 2 givenname: Andrew J surname: Bierhals fullname: Bierhals, Andrew J – sequence: 3 givenname: Cliff K surname: Choong fullname: Choong, Cliff K – sequence: 4 givenname: Seth T surname: Bartel fullname: Bartel, Seth T – sequence: 5 givenname: Jon H surname: Ritter fullname: Ritter, Jon H – sequence: 6 givenname: Nitin A surname: Das fullname: Das, Nitin A – sequence: 7 givenname: Cheng surname: Hong fullname: Hong, Cheng – sequence: 8 givenname: Thomas K surname: Pilgram fullname: Pilgram, Thomas K – sequence: 9 givenname: Kyongtae T surname: Bae fullname: Bae, Kyongtae T – sequence: 10 givenname: Bruce R surname: Whiting fullname: Whiting, Bruce R – sequence: 11 givenname: Jason C surname: Woods fullname: Woods, Jason C – sequence: 12 givenname: James C surname: Hogg fullname: Hogg, James C – sequence: 13 givenname: Barbara A surname: Lutey fullname: Lutey, Barbara A – sequence: 14 givenname: Richard J surname: Battafarano fullname: Battafarano, Richard J – sequence: 15 givenname: Joel D surname: Cooper fullname: Cooper, Joel D – sequence: 16 givenname: Bryan F surname: Meyers fullname: Meyers, Bryan F – sequence: 17 givenname: G Alexander surname: Patterson fullname: Patterson, G Alexander |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/19931472$$D View this record in MEDLINE/PubMed |
BookMark | eNpFkE1OwzAUhC0EorRwARbIF0hwHMd2lqgqP1IlNt1Xjv1M3TZOsB2JHoI7k7YgVu_TvNGMNFN06TsPCN0XJC9IwR-3udJB5ZSQOicyJ0RcoJtCCpkxwvgETWPcElJUXJbXaFLUdVkwQW_Q98Ja0CnizuL5CseRXedx2ji98xAjVt7gALrzMYXh_NxB8LDHI0Hbbw4RWoU_B-WTs06rkyXA_gRx43qcujEPcKs-vEuDgWPXURj7_gOcN_B1i66s2ke4-70ztHperOav2fL95W3-tMx6yquUVbXkVlTASsJ13bDSCGpNaYWpVcM0HyVhuZTasNFfScZKOvpJo6ipqKUz9HCO7YemBbPug2tVOKz_ZqE_wk9ozQ |
ContentType | Journal Article |
Copyright | Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved. |
Copyright_xml | – notice: Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved. |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1016/j.acra.2009.08.007 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1878-4046 |
ExternalDocumentID | 19931472 |
Genre | Journal Article Research Support, N.I.H., Extramural |
GrantInformation_xml | – fundername: NHLBI NIH HHS grantid: R01 HL072369 – fundername: NHLBI NIH HHS grantid: R01 HL72369 – fundername: NHLBI NIH HHS grantid: R01 HL070037 |
GroupedDBID | --- --K .1- .FO .GJ 0R~ 1B1 1P~ 23M 4.4 457 53G 5GY 5RE 5VS AAEDT AAEDW AALRI AAQFI AAQXK AAWTL AAXUO ABJNI ABMAC ABWVN ACGFS ACRPL ADBBV ADMUD ADNMO AENEX AEVXI AFCTW AFFNX AFJKZ AFRHN AFTJW AGCQF AGQPQ AIGII AITUG AJUYK ALMA_UNASSIGNED_HOLDINGS AMRAJ APXCP ASPBG AVWKF AZFZN BELOY C5W CGR CS3 CUY CVF EBS ECM EFJIC EFKBS EIF EJD F5P FDB FEDTE FGOYB G-Q HVGLF HZ~ IHE J1W KOM M41 MO0 NPM NQ- O9- OI~ OU0 P2P R2- ROL RPZ SEL SES SEW SJN SSZ UHS XH2 Z5R ZGI ZXP |
ID | FETCH-LOGICAL-p265t-5986f75e4306c9b43d72fd3f7d9ab4c69b47f688cd4265584432f750ba2d52f2 |
IngestDate | Mon Jul 21 06:01:10 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Language | English |
License | Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p265t-5986f75e4306c9b43d72fd3f7d9ab4c69b47f688cd4265584432f750ba2d52f2 |
PMID | 19931472 |
ParticipantIDs | pubmed_primary_19931472 |
PublicationCentury | 2000 |
PublicationDate | 2010-Feb |
PublicationDateYYYYMMDD | 2010-02-01 |
PublicationDate_xml | – month: 02 year: 2010 text: 2010-Feb |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Academic radiology |
PublicationTitleAlternate | Acad Radiol |
PublicationYear | 2010 |
SSID | ssj0015683 |
Score | 2.2856283 |
Snippet | Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 146 |
SubjectTerms | Aged Algorithms Female Humans Imaging, Three-Dimensional - methods Male Middle Aged Pattern Recognition, Automated - methods Pulmonary Emphysema - diagnostic imaging Radiographic Image Enhancement - methods Radiographic Image Interpretation, Computer-Assisted - methods Reproducibility of Results Sensitivity and Specificity Tomography, X-Ray Computed - methods |
Title | Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index |
URI | https://www.ncbi.nlm.nih.gov/pubmed/19931472 |
Volume | 17 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NTtwwELaWIlW9oEJ_KLSVD9xQqt3EiTdHiGhRJbgQJG7IicdaCvujbbjwDjwO78eM7XWyC1RtL1FkW3bk-TSZGX8zZmwvlUnd1wMVgVQiEjpPo6qqFLoqSa5qgwa3omzkk9Ps-Fz8vEgver2HDmvptqm-1XfP5pX8j1SxDeVKWbL_INkwKTbgO8oXnyhhfP6VjI9aMkZR7v8Gd-03MdivrQaz3HHyeEOV2P1rmE_gho4IYExRDRgrSqx0lCEHhvmCH0c8Lm-ajhWxjG514BTgeu0EtuRi18wNrPu50ldLgfsf-BtWWgU6fRt6PcSeEW5ZS7Nsj6yK0dRTh4ubK2Pa2OwhUVJtFPsMmpFnfPsgBp2_B0IIOMU7RG9W9H04cqGZZQeBcUfN-rDlE_XvIhG_EIpz5WuRElVWdgejCGdjCwjiLg6Euznoz70rJbkXXWtsDZ0Tum2VQkT-6CrNhonPznJEwtWPsXVq3QQrvoy1acq3bMM7I_zAIWuT9WCyxV6feLrFO3bvAcanhhcl9wDjAWAcAcaXAcYdwDi-BXzwZYDxLsB4M8X5gAeA0VrUgOu1E1iAvWfl96OyOI78_R3RLM7SJqLS_0amINAtrfNKJFrGRidGalQAos6wSZpsSNdn4Xi0hEUS4_h-pWKdxib-wF5NphPYZlwNVCYpqQz9aaGTYTXIBfRBQwaZyk38iX10-3g5czVaLhc7vPNizy570yLxM1s3iHD4ghZmU321En0Ee62BPQ |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effects+of+CT+section+thickness+and+reconstruction+kernel+on+emphysema+quantification+relationship+to+the+magnitude+of+the+CT+emphysema+index&rft.jtitle=Academic+radiology&rft.au=Gierada%2C+David+S&rft.au=Bierhals%2C+Andrew+J&rft.au=Choong%2C+Cliff+K&rft.au=Bartel%2C+Seth+T&rft.date=2010-02-01&rft.eissn=1878-4046&rft.volume=17&rft.issue=2&rft.spage=146&rft_id=info:doi/10.1016%2Fj.acra.2009.08.007&rft_id=info%3Apmid%2F19931472&rft_id=info%3Apmid%2F19931472&rft.externalDocID=19931472 |