Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index

Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. Low-radiation-dose multidetector CT was performed in 21 subjects representing a...

Full description

Saved in:
Bibliographic Details
Published inAcademic radiology Vol. 17; no. 2; p. 146
Main Authors Gierada, David S, Bierhals, Andrew J, Choong, Cliff K, Bartel, Seth T, Ritter, Jon H, Das, Nitin A, Hong, Cheng, Pilgram, Thomas K, Bae, Kyongtae T, Whiting, Bruce R, Woods, Jason C, Hogg, James C, Lutey, Barbara A, Battafarano, Richard J, Cooper, Joel D, Meyers, Bryan F, Patterson, G Alexander
Format Journal Article
LanguageEnglish
Published United States 01.02.2010
Subjects
Online AccessGet more information

Cover

Loading…
Abstract Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens. The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03). The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology.
AbstractList Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether their effects are related to the magnitude of the measurement. Low-radiation-dose multidetector CT was performed in 21 subjects representing a wide range of emphysema severity. Images were reconstructed using 20 different combinations of section thickness and reconstruction kernel. Emphysema index values were determined as the percentage of lung pixels having attenuation lower than multiple thresholds ranging from -960 HU to -890 HU. The index values obtained from the different thickness-kernel combinations were compared by repeated measures analysis of variance and Bland-Altman plots of mean versus difference in all subjects, and correlated with quantitative histology (mean linear intercept, Lm) in a subset of resected lung specimens. The effects of section thickness and reconstruction kernel on the emphysema index were significant (P < .001) and diminished as the index attenuation threshold was raised. The changes in index values from changing the thickness-kernel combination were largest for subjects with intermediate index values (10%-30%), and became progressively smaller for those with lower and higher index values. This pattern was consistent regardless of the thickness-kernel combinations compared and the HU threshold used. Correlations between the emphysema index values obtained with each thickness-kernel combination and Lm ranged from r = 0.55-0.68 (P = .007-.03). The effects of CT section thickness and kernel on emphysema index values varied systematically with the magnitude of the emphysema index. All reconstruction techniques provided significant correlations with quantitative histology.
Author Choong, Cliff K
Pilgram, Thomas K
Bierhals, Andrew J
Bae, Kyongtae T
Gierada, David S
Patterson, G Alexander
Woods, Jason C
Ritter, Jon H
Cooper, Joel D
Das, Nitin A
Hogg, James C
Lutey, Barbara A
Battafarano, Richard J
Whiting, Bruce R
Hong, Cheng
Bartel, Seth T
Meyers, Bryan F
Author_xml – sequence: 1
  givenname: David S
  surname: Gierada
  fullname: Gierada, David S
  email: gieradad@wustl.edu
  organization: Mallinckrodt Institute of Radiology, 510 S. Kingshighway Blvd., Washington University, St. Louis, MO 63105, USA. gieradad@wustl.edu
– sequence: 2
  givenname: Andrew J
  surname: Bierhals
  fullname: Bierhals, Andrew J
– sequence: 3
  givenname: Cliff K
  surname: Choong
  fullname: Choong, Cliff K
– sequence: 4
  givenname: Seth T
  surname: Bartel
  fullname: Bartel, Seth T
– sequence: 5
  givenname: Jon H
  surname: Ritter
  fullname: Ritter, Jon H
– sequence: 6
  givenname: Nitin A
  surname: Das
  fullname: Das, Nitin A
– sequence: 7
  givenname: Cheng
  surname: Hong
  fullname: Hong, Cheng
– sequence: 8
  givenname: Thomas K
  surname: Pilgram
  fullname: Pilgram, Thomas K
– sequence: 9
  givenname: Kyongtae T
  surname: Bae
  fullname: Bae, Kyongtae T
– sequence: 10
  givenname: Bruce R
  surname: Whiting
  fullname: Whiting, Bruce R
– sequence: 11
  givenname: Jason C
  surname: Woods
  fullname: Woods, Jason C
– sequence: 12
  givenname: James C
  surname: Hogg
  fullname: Hogg, James C
– sequence: 13
  givenname: Barbara A
  surname: Lutey
  fullname: Lutey, Barbara A
– sequence: 14
  givenname: Richard J
  surname: Battafarano
  fullname: Battafarano, Richard J
– sequence: 15
  givenname: Joel D
  surname: Cooper
  fullname: Cooper, Joel D
– sequence: 16
  givenname: Bryan F
  surname: Meyers
  fullname: Meyers, Bryan F
– sequence: 17
  givenname: G Alexander
  surname: Patterson
  fullname: Patterson, G Alexander
BackLink https://www.ncbi.nlm.nih.gov/pubmed/19931472$$D View this record in MEDLINE/PubMed
BookMark eNpFkE1OwzAUhC0EorRwARbIF0hwHMd2lqgqP1IlNt1Xjv1M3TZOsB2JHoI7k7YgVu_TvNGMNFN06TsPCN0XJC9IwR-3udJB5ZSQOicyJ0RcoJtCCpkxwvgETWPcElJUXJbXaFLUdVkwQW_Q98Ja0CnizuL5CseRXedx2ji98xAjVt7gALrzMYXh_NxB8LDHI0Hbbw4RWoU_B-WTs06rkyXA_gRx43qcujEPcKs-vEuDgWPXURj7_gOcN_B1i66s2ke4-70ztHperOav2fL95W3-tMx6yquUVbXkVlTASsJ13bDSCGpNaYWpVcM0HyVhuZTasNFfScZKOvpJo6ipqKUz9HCO7YemBbPug2tVOKz_ZqE_wk9ozQ
ContentType Journal Article
Copyright Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.
Copyright_xml – notice: Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1016/j.acra.2009.08.007
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
EISSN 1878-4046
ExternalDocumentID 19931472
Genre Journal Article
Research Support, N.I.H., Extramural
GrantInformation_xml – fundername: NHLBI NIH HHS
  grantid: R01 HL072369
– fundername: NHLBI NIH HHS
  grantid: R01 HL72369
– fundername: NHLBI NIH HHS
  grantid: R01 HL070037
GroupedDBID ---
--K
.1-
.FO
.GJ
0R~
1B1
1P~
23M
4.4
457
53G
5GY
5RE
5VS
AAEDT
AAEDW
AALRI
AAQFI
AAQXK
AAWTL
AAXUO
ABJNI
ABMAC
ABWVN
ACGFS
ACRPL
ADBBV
ADMUD
ADNMO
AENEX
AEVXI
AFCTW
AFFNX
AFJKZ
AFRHN
AFTJW
AGCQF
AGQPQ
AIGII
AITUG
AJUYK
ALMA_UNASSIGNED_HOLDINGS
AMRAJ
APXCP
ASPBG
AVWKF
AZFZN
BELOY
C5W
CGR
CS3
CUY
CVF
EBS
ECM
EFJIC
EFKBS
EIF
EJD
F5P
FDB
FEDTE
FGOYB
G-Q
HVGLF
HZ~
IHE
J1W
KOM
M41
MO0
NPM
NQ-
O9-
OI~
OU0
P2P
R2-
ROL
RPZ
SEL
SES
SEW
SJN
SSZ
UHS
XH2
Z5R
ZGI
ZXP
ID FETCH-LOGICAL-p265t-5986f75e4306c9b43d72fd3f7d9ab4c69b47f688cd4265584432f750ba2d52f2
IngestDate Mon Jul 21 06:01:10 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 2
Language English
License Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p265t-5986f75e4306c9b43d72fd3f7d9ab4c69b47f688cd4265584432f750ba2d52f2
PMID 19931472
ParticipantIDs pubmed_primary_19931472
PublicationCentury 2000
PublicationDate 2010-Feb
PublicationDateYYYYMMDD 2010-02-01
PublicationDate_xml – month: 02
  year: 2010
  text: 2010-Feb
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Academic radiology
PublicationTitleAlternate Acad Radiol
PublicationYear 2010
SSID ssj0015683
Score 2.2856283
Snippet Computed tomography (CT) section thickness and reconstruction kernel each influence CT measurements of emphysema. This study was performed to assess whether...
SourceID pubmed
SourceType Index Database
StartPage 146
SubjectTerms Aged
Algorithms
Female
Humans
Imaging, Three-Dimensional - methods
Male
Middle Aged
Pattern Recognition, Automated - methods
Pulmonary Emphysema - diagnostic imaging
Radiographic Image Enhancement - methods
Radiographic Image Interpretation, Computer-Assisted - methods
Reproducibility of Results
Sensitivity and Specificity
Tomography, X-Ray Computed - methods
Title Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index
URI https://www.ncbi.nlm.nih.gov/pubmed/19931472
Volume 17
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NTtwwELaWIlW9oEJ_KLSVD9xQqt3EiTdHiGhRJbgQJG7IicdaCvujbbjwDjwO78eM7XWyC1RtL1FkW3bk-TSZGX8zZmwvlUnd1wMVgVQiEjpPo6qqFLoqSa5qgwa3omzkk9Ps-Fz8vEgver2HDmvptqm-1XfP5pX8j1SxDeVKWbL_INkwKTbgO8oXnyhhfP6VjI9aMkZR7v8Gd-03MdivrQaz3HHyeEOV2P1rmE_gho4IYExRDRgrSqx0lCEHhvmCH0c8Lm-ajhWxjG514BTgeu0EtuRi18wNrPu50ldLgfsf-BtWWgU6fRt6PcSeEW5ZS7Nsj6yK0dRTh4ubK2Pa2OwhUVJtFPsMmpFnfPsgBp2_B0IIOMU7RG9W9H04cqGZZQeBcUfN-rDlE_XvIhG_EIpz5WuRElVWdgejCGdjCwjiLg6Euznoz70rJbkXXWtsDZ0Tum2VQkT-6CrNhonPznJEwtWPsXVq3QQrvoy1acq3bMM7I_zAIWuT9WCyxV6feLrFO3bvAcanhhcl9wDjAWAcAcaXAcYdwDi-BXzwZYDxLsB4M8X5gAeA0VrUgOu1E1iAvWfl96OyOI78_R3RLM7SJqLS_0amINAtrfNKJFrGRidGalQAos6wSZpsSNdn4Xi0hEUS4_h-pWKdxib-wF5NphPYZlwNVCYpqQz9aaGTYTXIBfRBQwaZyk38iX10-3g5czVaLhc7vPNizy570yLxM1s3iHD4ghZmU321En0Ee62BPQ
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effects+of+CT+section+thickness+and+reconstruction+kernel+on+emphysema+quantification+relationship+to+the+magnitude+of+the+CT+emphysema+index&rft.jtitle=Academic+radiology&rft.au=Gierada%2C+David+S&rft.au=Bierhals%2C+Andrew+J&rft.au=Choong%2C+Cliff+K&rft.au=Bartel%2C+Seth+T&rft.date=2010-02-01&rft.eissn=1878-4046&rft.volume=17&rft.issue=2&rft.spage=146&rft_id=info:doi/10.1016%2Fj.acra.2009.08.007&rft_id=info%3Apmid%2F19931472&rft_id=info%3Apmid%2F19931472&rft.externalDocID=19931472