Confounding factors in breast magnetic resonance fingerprinting: B1+, slice profile, and diffusion effects

Purpose Magnetic resonance fingerprinting (MRF) offers rapid quantitative imaging but may be subject to confounding effects (CE) if these are not included in the model‐based reconstruction. This study characterizes the influence of in‐plane B1+, slice profile and diffusion effects on T1 and T2 estim...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 85; no. 4; pp. 1865 - 1880
Main Authors Nolte, Teresa, Scholten, Hannah, Gross‐Weege, Nicolas, Amthor, Thomas, Koken, Peter, Doneva, Mariya, Schulz, Volkmar
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc 01.04.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose Magnetic resonance fingerprinting (MRF) offers rapid quantitative imaging but may be subject to confounding effects (CE) if these are not included in the model‐based reconstruction. This study characterizes the influence of in‐plane B1+, slice profile and diffusion effects on T1 and T2 estimation in the female breast at 1.5T. Methods Simulations were used to predict the influence of each CE on the accuracy of MRF and to investigate the influence of electronic noise and spiral aliasing artefacts. The experimentally observed bias in regions of fibroglandular tissue (FGT) and fatty tissue (FT) was analyzed for undersampled spiral breast MRF data of 6 healthy volunteers by performing MRF reconstruction with and without a CE. Results Theoretic analysis predicts T1 under‐/T2 overestimation if the nominal flip angles are underestimated and inversely, T1 under‐/T2 overestimation if omitting slice profile correction, and T1 under‐/T2 underestimation if omitting diffusion in the signal model. Averaged over repeated signal simulations, including spiral aliasing artefacts affected precision more than accuracy. Strong in‐plane B1+ effects occurred in vivo, causing T2 left–right inhomogeneity between both breasts. Their correction decreased the T2 difference from 29 to 5 ms in FGT and from 29 to 9 ms in FT. Slice profile correction affected FGT T2 most strongly, resulting in −22% smaller values. For the employed spoiler gradient strengths, diffusion did not affect the parameter maps, corresponding well with theoretic predictions. Conclusion Understanding CEs and their relative significance for an MRF sequence is important when defining an MRF signal model for accurate parameter mapping.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.28545