Effects of variation of MRI parameters on signal homogeneity: A Qualitative analysis for Ferrous Benzoic Xylenon Orange gel

This study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences. A tissue equivalent gel system has been used for Magnetic Resonance Imaging by using Xylenol orange dye with Fricke-Benzoic solution which was formulated by Kelly R.G (1998)....

Full description

Saved in:
Bibliographic Details
Published inJournal of the Pakistan Medical Association Vol. 60; no. 6; pp. 470 - 473
Main Authors NAZIR, Aalia, AFZAL, Muhammad, SAEED AHMAD BUZDAR
Format Journal Article
LanguageEnglish
Published Karachi Pakistan Medical Association 01.06.2010
Subjects
Online AccessGet full text

Cover

Loading…
Abstract This study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences. A tissue equivalent gel system has been used for Magnetic Resonance Imaging by using Xylenol orange dye with Fricke-Benzoic solution which was formulated by Kelly R.G (1998). The gel system was radiated while using 6MV photons from Varian Clinic Linear Accelerator. The qualitative analysis include the effect of TR and TE on signal nonuniformity according to which the escalating repetition time gives a uniform signal having the average values calculated are 0.76%, 0.83%, 1.43% and 1.89% for the conventional spin echo (CSE), fast spin echo (FSE), gradient recalled echo (GRE) and fluid attenuated inversion recovery (FLAIR) respectively. FLAIR showed contradictory results due to longitudinal relaxation of the signal. This is because, at the longer value of inversion time (TI), the signal from simple fluids is nulled, thus reducing signal intensity. The evaluation of signal uniformity for different pulse sequences demonstrates that the repetition time (TR) affects the signal homogeneity as it maintains image quality for CSE and FSE. However, a careful selection is required for FLAIR due to its sensitive behaviour for image uniformity.
AbstractList OBJECTIVEThis study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences.METHODSA tissue equivalent gel system has been used for Magnetic Resonance Imaging by using Xylenol orange dye with Fricke-Benzoic solution which was formulated by Kelly R.G (1998). The gel system was radiated while using 6MV photons from Varian Clinic Linear Accelerator.RESULTSThe qualitative analysis include the effect of TR and TE on signal nonuniformity according to which the escalating repetition time gives a uniform signal having the average values calculated are 0.76%, 0.83%, 1.43% and 1.89% for the conventional spin echo (CSE), fast spin echo (FSE), gradient recalled echo (GRE) and fluid attenuated inversion recovery (FLAIR) respectively. FLAIR showed contradictory results due to longitudinal relaxation of the signal. This is because, at the longer value of inversion time (TI), the signal from simple fluids is nulled, thus reducing signal intensity.CONCLUSIONThe evaluation of signal uniformity for different pulse sequences demonstrates that the repetition time (TR) affects the signal homogeneity as it maintains image quality for CSE and FSE. However, a careful selection is required for FLAIR due to its sensitive behaviour for image uniformity.
This study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences. A tissue equivalent gel system has been used for Magnetic Resonance Imaging by using Xylenol orange dye with Fricke-Benzoic solution which was formulated by Kelly R.G (1998). The gel system was radiated while using 6MV photons from Varian Clinic Linear Accelerator. The qualitative analysis include the effect of TR and TE on signal nonuniformity according to which the escalating repetition time gives a uniform signal having the average values calculated are 0.76%, 0.83%, 1.43% and 1.89% for the conventional spin echo (CSE), fast spin echo (FSE), gradient recalled echo (GRE) and fluid attenuated inversion recovery (FLAIR) respectively. FLAIR showed contradictory results due to longitudinal relaxation of the signal. This is because, at the longer value of inversion time (TI), the signal from simple fluids is nulled, thus reducing signal intensity. The evaluation of signal uniformity for different pulse sequences demonstrates that the repetition time (TR) affects the signal homogeneity as it maintains image quality for CSE and FSE. However, a careful selection is required for FLAIR due to its sensitive behaviour for image uniformity.
Author SAEED AHMAD BUZDAR
NAZIR, Aalia
AFZAL, Muhammad
Author_xml – sequence: 1
  givenname: Aalia
  surname: NAZIR
  fullname: NAZIR, Aalia
  organization: Department of Physics, The Islamia University of Bahawalpur, Pakistan
– sequence: 2
  givenname: Muhammad
  surname: AFZAL
  fullname: AFZAL, Muhammad
  organization: Department of Physics, The Islamia University of Bahawalpur, Pakistan
– sequence: 3
  surname: SAEED AHMAD BUZDAR
  fullname: SAEED AHMAD BUZDAR
  organization: Department of Physics, The Islamia University of Bahawalpur, Pakistan
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=23059903$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/20527646$$D View this record in MEDLINE/PubMed
BookMark eNpFkE9LxDAQxXtYcf_oV5BcxFMhTdqm9bYuqy6sLIqCtzLtTmqkTWrSLlS_vBFXPA2P95uZNzMPJtponAQzSjkN8zxj02Du3DulLE0oPQ2mjCZMpHE6C77WUmLVO2IkOYBV0Cujf8TD04Z0YKHFHq23NXGq1tCQN9OaGjWqfrwmS_I4QKN633ZAAt4fnXJEGktu0VozOHKD-tOoiryODfpcZGdB10hqbM6CEwmNw_NjXQQvt-vn1X243d1tVstt2LGY9iHjlchlySCCpEwEyyuIk1hA7iWPRVyyLCrLUiQoIso9l8SSVeU-S7OMp0LyRXD1O7ez5mNA1xetchU2DWj0CQvBuV_Eo9iTF0dyKFvcF51VLdix-PuXBy6PALgKGulvqZT75zhN8pxy_g0Dz3Vm
CODEN JJPAD4
ContentType Journal Article
Copyright 2015 INIST-CNRS
Copyright_xml – notice: 2015 INIST-CNRS
DBID IQODW
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DatabaseName Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EndPage 473
ExternalDocumentID 20527646
23059903
Genre Evaluation Studies
Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
.55
0ZK
2WC
53G
5GY
AAUGY
ABCQX
ABUBX
ACGFO
ACMJI
ADCHZ
ADEYR
AEGXH
AENEX
AFACB
AFJDA
AGFXM
AGNLS
AGQRV
AHEHV
AHHXF
AHKOF
AIAGR
AKNUK
ALMA_UNASSIGNED_HOLDINGS
AOWDX
BAI
BAW
DIK
E3Z
EBD
EMOBN
EOJEC
F5P
FRP
GROUPED_DOAJ
GX1
IAO
IEA
IHR
IHW
INH
INR
IQODW
ITC
L7B
LGEZI
LOTEE
LXO
MK0
MV.
NADUK
NFBOU
NKUNM
NXXTH
NYMDV
OBODZ
OK1
P2P
PV9
RXW
RZL
SV3
TAA
TAF
TUS
UNMZH
USXSC
W2D
X7M
~ZZ
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-p240t-23c79fb2a1a5b5729ca4547a9a5b3474b281bbb75e7103b2a54f2cbd8688367f3
ISSN 0030-9982
IngestDate Fri Jun 28 11:19:29 EDT 2024
Sat Sep 28 07:47:28 EDT 2024
Sun Oct 22 16:08:56 EDT 2023
IsPeerReviewed false
IsScholarly true
Issue 6
Keywords Medical imagery
Tropical medicine
Qualitative analysis
Nuclear magnetic resonance imaging
Language English
License CC BY 4.0
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p240t-23c79fb2a1a5b5729ca4547a9a5b3474b281bbb75e7103b2a54f2cbd8688367f3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 20527646
PQID 733240314
PQPubID 23479
PageCount 4
ParticipantIDs proquest_miscellaneous_733240314
pubmed_primary_20527646
pascalfrancis_primary_23059903
PublicationCentury 2000
PublicationDate 2010-06-01
PublicationDateYYYYMMDD 2010-06-01
PublicationDate_xml – month: 06
  year: 2010
  text: 2010-06-01
  day: 01
PublicationDecade 2010
PublicationPlace Karachi
PublicationPlace_xml – name: Karachi
– name: Pakistan
PublicationTitle Journal of the Pakistan Medical Association
PublicationTitleAlternate J Pak Med Assoc
PublicationYear 2010
Publisher Pakistan Medical Association
Publisher_xml – name: Pakistan Medical Association
SSID ssj0026500
Score 1.8840832
Snippet This study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences. A tissue equivalent gel system has...
OBJECTIVEThis study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences.METHODSA tissue equivalent...
SourceID proquest
pubmed
pascalfrancis
SourceType Aggregation Database
Index Database
StartPage 470
SubjectTerms Biological and medical sciences
Ferrous Compounds - chemistry
Fluorescent Dyes
Gels - radiation effects
General aspects
Humans
Image Enhancement - methods
Image Processing, Computer-Assisted - methods
Magnetic Resonance Imaging - methods
Medical sciences
Phantoms, Imaging
Phenols
Qualitative Research
Radiometry - methods
Reproducibility of Results
Signal Processing, Computer-Assisted
Sulfoxides
Xylenes
Title Effects of variation of MRI parameters on signal homogeneity: A Qualitative analysis for Ferrous Benzoic Xylenon Orange gel
URI https://www.ncbi.nlm.nih.gov/pubmed/20527646
https://search.proquest.com/docview/733240314
Volume 60
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LbxMxELbSHhAXRHkGSuUDt2hRdv3YDTdDE1JEQKpaKcolsh1b5ZCkCgkS7aU_nZm1s7upigpcrKyVOF7PJ3tm_M0MIW8l47LQkic2ZT7hpusS0ytE4gDQPptpz8qqJaOvcnjOP4_FuNW6abCWNmvzzl7dGVfyP1KFPpArRsn-g2SrQaEDPoN8oQUJQ_tXMu7XZIyfYPNW2t_o9KSDOb3nyHUp7wOQpoFRj8v5EkZzWAqgDEkPKTRC8m-9zU-CzMOBW62QHfvBLa6W321n_AuOJxjo2wqjETqRCXuHWouKbFRL62ug2yBA77OanJQkDIWelgp3g4n6UjppNxd6PtezygOk-v3jjhqOFNYKmRyr06a_Aq_aZdNfce8M4kbNuglYgjsbdSg8EAHZ3HV5qD0SD3AeaqPs5ta-deZVTESwwAQcyGyP7LEUKaGfxhVFKAPtNab1DJNB4qz-AZP2oejJn62SUjs5e0wexfWnKmDkgLTc4gl5MIrEiafkOkKFLj2toIIPABVaQ4VCZ4AKbUDlPVW0ARS6BQoFoNAIFBqBQiNQaAAKBaA8I-eD_tnHYRLrbiSXoN-tk4zZvOdNplMtjADry2pM-6Z78Mh4zk0Gto4xuXCgnjL4nuA-s2ZWyKJgMvfsOdmHP3IvCfWFQ_0HbGqhuWUOmrSYCWGsFfDepk2OdlZ0ehlyrEy3cmkTul3iKWx8eJulFw5ea5qzMpdkytvkRVj6-sddkeWSy1f3jf6aPKwhekj216uNewNK5toclUj4DX50hvY
link.rule.ids 315,786,790
linkProvider Geneva Foundation for Medical Education and Research
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effects+of+variation+of+MRI+parameters+on+signal+homogeneity%3A+A+Qualitative+analysis+for+Ferrous+Benzoic+Xylenon+Orange+gel&rft.jtitle=Journal+of+the+Pakistan+Medical+Association&rft.au=NAZIR%2C+Aalia&rft.au=AFZAL%2C+Muhammad&rft.au=SAEED+AHMAD+BUZDAR&rft.date=2010-06-01&rft.pub=Pakistan+Medical+Association&rft.issn=0030-9982&rft.volume=60&rft.issue=6&rft.spage=470&rft.epage=473&rft.externalDBID=n%2Fa&rft.externalDocID=23059903
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0030-9982&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0030-9982&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0030-9982&client=summon