The accuracy of fetal pulse oximetry in the second stage of labour

The aim of this study is to assess the accuracy of fetal monitoring with pulse oximetry at delivery. The pulse oximetry reading from the fetus at delivery was compared to fetal condition at birth. There is poor correlation between fetal scalp oximetry readings at delivery and fetal condition (Apgar...

Full description

Saved in:
Bibliographic Details
Published inJournal of perinatal medicine Vol. 19; no. 4; p. 297
Main Authors Johnson, N, Johnson, V A, Bannister, J, Lilford, R J
Format Journal Article
LanguageEnglish
Published Germany 1991
Subjects
Online AccessGet more information

Cover

Loading…
Abstract The aim of this study is to assess the accuracy of fetal monitoring with pulse oximetry at delivery. The pulse oximetry reading from the fetus at delivery was compared to fetal condition at birth. There is poor correlation between fetal scalp oximetry readings at delivery and fetal condition (Apgar scores), umbilical venous or arterial blood gas analysis or pH. Although there are good theoretical reasons why the correlation should not be perfect, the wide deviation from expected values suggest that readings taken during delivery are particularly prone to errors. Examination of the unprocessed photodetector signal during the second stage of labour reveals considerable movement interference. The signal may also be affected by congestion and transmitted venous pulsation in the scalp as the head crowns. The current generation of reflectance pulse oximeters can predict fetal hypoxemia during labour but a single reading during delivery is subject to too much movement interference to produce useful data.
AbstractList The aim of this study is to assess the accuracy of fetal monitoring with pulse oximetry at delivery. The pulse oximetry reading from the fetus at delivery was compared to fetal condition at birth. There is poor correlation between fetal scalp oximetry readings at delivery and fetal condition (Apgar scores), umbilical venous or arterial blood gas analysis or pH. Although there are good theoretical reasons why the correlation should not be perfect, the wide deviation from expected values suggest that readings taken during delivery are particularly prone to errors. Examination of the unprocessed photodetector signal during the second stage of labour reveals considerable movement interference. The signal may also be affected by congestion and transmitted venous pulsation in the scalp as the head crowns. The current generation of reflectance pulse oximeters can predict fetal hypoxemia during labour but a single reading during delivery is subject to too much movement interference to produce useful data.
Author Johnson, V A
Johnson, N
Lilford, R J
Bannister, J
Author_xml – sequence: 1
  givenname: N
  surname: Johnson
  fullname: Johnson, N
  organization: Department of Obstetrics & Gynaecology, St. James's University Hospital, Leeds, England
– sequence: 2
  givenname: V A
  surname: Johnson
  fullname: Johnson, V A
– sequence: 3
  givenname: J
  surname: Bannister
  fullname: Bannister, J
– sequence: 4
  givenname: R J
  surname: Lilford
  fullname: Lilford, R J
BackLink https://www.ncbi.nlm.nih.gov/pubmed/1960633$$D View this record in MEDLINE/PubMed
BookMark eNotj81qwzAQhHVISZM0j1DQCxhWkleuj23oHwR6Sc9hLa0aF9sylg3129elOc3lY76ZrVh1seOV2IAByBCL4lZsU_oGUIio12KtSgvWmI14Ol1YknPTQG6WMcjAIzWyn5rEMv7ULY_DLOtOjguX2MXOyzTSF_-xDVVxGu7ETaAF319zJz5fnk-Ht-z48fp-eDxmvTY4ZqGAvMRFmjvWpdeQQ1lRoQjAeW-QHjDYZZdnqAqP2lWQo1UMxnpLyuiduP_v7aeqZX_uh7qlYT5fv-hfvSxFJA
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
ExternalDocumentID 1960633
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
-~0
.GJ
0R~
0~D
34G
36B
39C
3O-
4.4
53G
5GY
5RE
9-L
AAAEU
AABBZ
AAFNC
AAFPC
AAGVJ
AAKAS
AALGR
AAONY
AAOQK
AAOTM
AAOWA
AAPJK
AAQCX
AAQQT
AASQH
AAWFC
AAWTL
AAXCG
ABAOT
ABAQN
ABFKT
ABFQV
ABIQR
ABJNI
ABMIY
ABPLS
ABRDF
ABRQL
ABUBZ
ABUVI
ABVMU
ABWLS
ABXMZ
ABYBW
ACDEB
ACEFL
ACGFS
ACMKP
ACPMA
ACRPL
ACXLN
ACZBO
ADALX
ADDWE
ADEQT
ADGQD
ADGYE
ADNMO
ADOZN
ADUQZ
ADZCM
AEGVQ
AEICA
AEJTT
AEKEB
AENEX
AEQDQ
AERZL
AEXIE
AFAUI
AFBAA
AFCXV
AFFNX
AFGDO
AFGNR
AFQUK
AFSHE
AFYRI
AGBEV
AGGNV
AHMBA
AHOVO
AHVWV
AHXUK
AIERV
AIKXB
AJATJ
AJHHK
AKXKS
ALMA_UNASSIGNED_HOLDINGS
ALYBR
AMAVY
ASPBG
ASYPN
AVWKF
AZFZN
AZMOX
BAKPI
BBCWN
BCIFA
BWHEM
CAG
CGQUA
CGR
COF
CS3
CUY
CVF
DA2
DBYYV
DU5
EBS
ECM
EIF
EJD
EMOBN
F5P
FEDTE
FSTRU
HVGLF
HZ~
IL9
IY9
KDIRW
LVMAB
N4W
NPM
O9-
OVD
PQQKQ
QD8
RDG
SA.
SLJYH
TEORI
UK5
WTRAM
ZGI
ZXP
~Z8
ID FETCH-LOGICAL-p235t-f704956334ce29d20409ba71a00cdd35a85f6196de0b7d52cb04561e036d6a132
ISSN 0300-5577
IngestDate Wed Feb 19 00:41:50 EST 2025
IsPeerReviewed true
IsScholarly true
Issue 4
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p235t-f704956334ce29d20409ba71a00cdd35a85f6196de0b7d52cb04561e036d6a132
PMID 1960633
ParticipantIDs pubmed_primary_1960633
PublicationCentury 1900
PublicationDate 1991-00-00
PublicationDateYYYYMMDD 1991-01-01
PublicationDate_xml – year: 1991
  text: 1991-00-00
PublicationDecade 1990
PublicationPlace Germany
PublicationPlace_xml – name: Germany
PublicationTitle Journal of perinatal medicine
PublicationTitleAlternate J Perinat Med
PublicationYear 1991
SSID ssj0015552
Score 1.4077034
Snippet The aim of this study is to assess the accuracy of fetal monitoring with pulse oximetry at delivery. The pulse oximetry reading from the fetus at delivery was...
SourceID pubmed
SourceType Index Database
StartPage 297
SubjectTerms Cardiotocography
Female
Fetal Blood
Fetal Monitoring - standards
Humans
Labor, Obstetric
Oximetry - methods
Oximetry - standards
Oxygen - blood
Pregnancy
Title The accuracy of fetal pulse oximetry in the second stage of labour
URI https://www.ncbi.nlm.nih.gov/pubmed/1960633
Volume 19
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ3NS8MwFMCDU5RdxK_hNzl4jbRp0o-jijLEeZBNdhtNk8Bg68bsQP3rfWnSWYcT9RJKEkqbX5q-95L3HkIXSQZyBQtSooQMCYN_DkmZL4lIQhGlLKBSG0fhzmPY7rH7Pu9XOdudd0khLrP3b_1K_kMV6oCr8ZL9A9nFTaECroEvlEAYyl8zTrNsPjM520Hq08q4Nk7nI2Ogfx2OVTF7qw4yvhjNVxrTgTUTGPrz2QrZ1IQ_zsu8Ist77y6j1pdNnFrdc902mpuovHZKLKzRD8NRdZz-ydVK54Tn12wOztfK8wjnLgFLtY4mtfnC6ouiPYFbAzIdl0R8oz7ZOBg_Ni5FxHYtDdQA1cDkOjUGGrdxxDl3G0f2AZto03Vf0htK-aG7g7bd4OIrS3EXral8D2113PDuo2uAiSuYeKJxCROXMHEFEw9zDDCxhYlLmKavhXmAene33Zs2cQkuyJQGvCA68ox-GgQsUzSRFBbURKSRn3peJmXA05hrUHBDqTwRSU4zYQRwX4HUIcPUD2gLreeTXB0izCKtYgXKr6YBixT8O3QcZ4L6mmsV6vgItezbD6Y2isnADcvxqoYT1PxEf4o2NHw06gwksEKcl2P-AfWBMmw
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+accuracy+of+fetal+pulse+oximetry+in+the+second+stage+of+labour&rft.jtitle=Journal+of+perinatal+medicine&rft.au=Johnson%2C+N&rft.au=Johnson%2C+V+A&rft.au=Bannister%2C+J&rft.au=Lilford%2C+R+J&rft.date=1991-01-01&rft.issn=0300-5577&rft.volume=19&rft.issue=4&rft.spage=297&rft_id=info%3Apmid%2F1960633&rft_id=info%3Apmid%2F1960633&rft.externalDocID=1960633
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0300-5577&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0300-5577&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0300-5577&client=summon