Ultrathin Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization: 3-Year Outcomes From the Randomized BIOFLOW V Trial

The aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81μm) durable-polymer everolimus-eluting stents (DP EES). Emerging evidence from comparative studies of drug-el...

Full description

Saved in:
Bibliographic Details
Published inJACC. Cardiovascular interventions Vol. 13; no. 11; p. 1343
Main Authors Kandzari, David E, Koolen, Jacques J, Doros, Gheorghe, Garcia-Garcia, Hector M, Bennett, Johan, Roguin, Ariel, Gharib, Elie G, Cutlip, Donald E, Waksman, Ron
Format Journal Article
LanguageEnglish
Published United States 08.06.2020
Subjects
Online AccessGet full text
ISSN1876-7605
1876-7605
DOI10.1016/j.jcin.2020.02.019

Cover

Loading…
Abstract The aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81μm) durable-polymer everolimus-eluting stents (DP EES). Emerging evidence from comparative studies of drug-eluting stents demonstrates improved safety and efficacy with ultrathin-strut drug-eluting stents, but limited insight exists regarding late-term outcomes. BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With Up to Three De Novo or Restenotic Coronary Artery Lesions V) is an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure. Analysis of pre-specified 3-year clinical outcomes was performed. Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 3-year rate of target lesion failure was 8.2% for BP SES and 13.6% for DP EES (p = 0.002), driven by differences in both target vessel myocardial infarction (MI) (5.0% vs. 9.2%; p = 0.003) and clinically driven target lesion revascularization (3.2% vs. 6.7%; p = 0.006). In landmark analysis, significant differences in target vessel MI and target lesion revascularization were observed favoring treatment with BP SES. Definite or probable late or very late stent thrombosis was significantly lower with BP SES (0.1% vs. 1.2%; p = 0.018). Cardiac death or MI rates were 7.7% and 11.7% (p = 0.017) for BP SES and DP EES, respectively. In a large randomized trial, both target lesion failure and the outcomes of target vessel MI, clinically driven target lesion revascularization, and late or very late stent thrombosis at 3 years were significantly lower among patients treated with BP SES versus DP EES. The results endorse the continued superiority of ultrathin-strut BP SES compared with DP EES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946).
AbstractList The aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81μm) durable-polymer everolimus-eluting stents (DP EES).OBJECTIVESThe aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81μm) durable-polymer everolimus-eluting stents (DP EES).Emerging evidence from comparative studies of drug-eluting stents demonstrates improved safety and efficacy with ultrathin-strut drug-eluting stents, but limited insight exists regarding late-term outcomes.BACKGROUNDEmerging evidence from comparative studies of drug-eluting stents demonstrates improved safety and efficacy with ultrathin-strut drug-eluting stents, but limited insight exists regarding late-term outcomes.BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With Up to Three De Novo or Restenotic Coronary Artery Lesions V) is an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure. Analysis of pre-specified 3-year clinical outcomes was performed.METHODSBIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With Up to Three De Novo or Restenotic Coronary Artery Lesions V) is an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure. Analysis of pre-specified 3-year clinical outcomes was performed.Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 3-year rate of target lesion failure was 8.2% for BP SES and 13.6% for DP EES (p = 0.002), driven by differences in both target vessel myocardial infarction (MI) (5.0% vs. 9.2%; p = 0.003) and clinically driven target lesion revascularization (3.2% vs. 6.7%; p = 0.006). In landmark analysis, significant differences in target vessel MI and target lesion revascularization were observed favoring treatment with BP SES. Definite or probable late or very late stent thrombosis was significantly lower with BP SES (0.1% vs. 1.2%; p = 0.018). Cardiac death or MI rates were 7.7% and 11.7% (p = 0.017) for BP SES and DP EES, respectively.RESULTSAmong 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 3-year rate of target lesion failure was 8.2% for BP SES and 13.6% for DP EES (p = 0.002), driven by differences in both target vessel myocardial infarction (MI) (5.0% vs. 9.2%; p = 0.003) and clinically driven target lesion revascularization (3.2% vs. 6.7%; p = 0.006). In landmark analysis, significant differences in target vessel MI and target lesion revascularization were observed favoring treatment with BP SES. Definite or probable late or very late stent thrombosis was significantly lower with BP SES (0.1% vs. 1.2%; p = 0.018). Cardiac death or MI rates were 7.7% and 11.7% (p = 0.017) for BP SES and DP EES, respectively.In a large randomized trial, both target lesion failure and the outcomes of target vessel MI, clinically driven target lesion revascularization, and late or very late stent thrombosis at 3 years were significantly lower among patients treated with BP SES versus DP EES. The results endorse the continued superiority of ultrathin-strut BP SES compared with DP EES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946).CONCLUSIONSIn a large randomized trial, both target lesion failure and the outcomes of target vessel MI, clinically driven target lesion revascularization, and late or very late stent thrombosis at 3 years were significantly lower among patients treated with BP SES versus DP EES. The results endorse the continued superiority of ultrathin-strut BP SES compared with DP EES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946).
The aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting stents (BP SES) and thin-strut (81μm) durable-polymer everolimus-eluting stents (DP EES). Emerging evidence from comparative studies of drug-eluting stents demonstrates improved safety and efficacy with ultrathin-strut drug-eluting stents, but limited insight exists regarding late-term outcomes. BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects With Up to Three De Novo or Restenotic Coronary Artery Lesions V) is an international randomized trial comparing coronary revascularization with BP SES and DP EES regarding the primary endpoint of 12-month target lesion failure. Analysis of pre-specified 3-year clinical outcomes was performed. Among 1,334 patients randomized to treatment with BP SES (n = 884) or DP EES (n = 450), the 3-year rate of target lesion failure was 8.2% for BP SES and 13.6% for DP EES (p = 0.002), driven by differences in both target vessel myocardial infarction (MI) (5.0% vs. 9.2%; p = 0.003) and clinically driven target lesion revascularization (3.2% vs. 6.7%; p = 0.006). In landmark analysis, significant differences in target vessel MI and target lesion revascularization were observed favoring treatment with BP SES. Definite or probable late or very late stent thrombosis was significantly lower with BP SES (0.1% vs. 1.2%; p = 0.018). Cardiac death or MI rates were 7.7% and 11.7% (p = 0.017) for BP SES and DP EES, respectively. In a large randomized trial, both target lesion failure and the outcomes of target vessel MI, clinically driven target lesion revascularization, and late or very late stent thrombosis at 3 years were significantly lower among patients treated with BP SES versus DP EES. The results endorse the continued superiority of ultrathin-strut BP SES compared with DP EES. (Safety and Effectiveness of the Orsiro Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions [BIOFLOW-V]; NCT02389946).
Author Garcia-Garcia, Hector M
Waksman, Ron
Cutlip, Donald E
Roguin, Ariel
Kandzari, David E
Gharib, Elie G
Koolen, Jacques J
Bennett, Johan
Doros, Gheorghe
Author_xml – sequence: 1
  givenname: David E
  surname: Kandzari
  fullname: Kandzari, David E
  email: david.kandzari@piedmont.org
  organization: Piedmont Heart Institute, Atlanta, Georgia. Electronic address: david.kandzari@piedmont.org
– sequence: 2
  givenname: Jacques J
  surname: Koolen
  fullname: Koolen, Jacques J
  organization: Catharina Hospital, Eindhoven, the Netherlands
– sequence: 3
  givenname: Gheorghe
  surname: Doros
  fullname: Doros, Gheorghe
  organization: Department of Biostatistics and Epidemiology, Boston University School of Public Health, Baim Institute for Clinical Research, Boston, Massachusetts
– sequence: 4
  givenname: Hector M
  surname: Garcia-Garcia
  fullname: Garcia-Garcia, Hector M
  organization: Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC
– sequence: 5
  givenname: Johan
  surname: Bennett
  fullname: Bennett, Johan
  organization: Department of Cardiovascular Medicine, University Hospitals Leuven, Leuven, Belgium
– sequence: 6
  givenname: Ariel
  surname: Roguin
  fullname: Roguin, Ariel
  organization: Department of Cardiology, Hillel Yaffe Medical Center, Hadera, Israel
– sequence: 7
  givenname: Elie G
  surname: Gharib
  fullname: Gharib, Elie G
  organization: Charleston Area Medical Center, Charleston, West Virginia
– sequence: 8
  givenname: Donald E
  surname: Cutlip
  fullname: Cutlip, Donald E
  organization: Beth Israel Deaconess Medical Center, Baim Institute for Clinical Research, Boston, Massachusetts
– sequence: 9
  givenname: Ron
  surname: Waksman
  fullname: Waksman, Ron
  organization: Division of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC
BackLink https://www.ncbi.nlm.nih.gov/pubmed/32499026$$D View this record in MEDLINE/PubMed
BookMark eNp1kE1PGzEQhq2KqhDaP9AD8pHLbv2x3vVygzRpkSKlgkDVUzTZnQVHXjv4Awl-Xn9ZU5VK9NDTzOF53tG8E3LgvENCPnJWcsbrT9ty2xlXCiZYyUTJePuGHHHd1EVTM3Xwaj8kkxi3jNWsbcQ7cihF1bZM1Efk541NAdK9cfTC-IDRhw1sLBbfvH0aMdBrE7w1Y47FzOZk3B29TuhSpLcYYo509Vv9nMM_0uwR_2MNPtCpD95BeKJX-AixyxaCeYZkvDujsviBEOgyp86PGOk8-JGme6RX4Ho_mmfs6cXlcr5Yfqe3dBUM2Pfk7QA24oeXeUxu5rPV9GuxWH65nJ4vip3gPBWi4k2tO9lVndaoe6h0z5pm0w5KVRWgqgAEIIMGBymYlqA0Y6pR3VDDoJU8Jqd_cnfBP2SMaT2a2KG14NDnuN4fYFLxVoo9evKC5s2I_XoXzLh_eP23d_kLdI6Lwg
ContentType Journal Article
Copyright Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.
Copyright_xml – notice: Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.
CorporateAuthor BIOFLOW V Investigators
CorporateAuthor_xml – name: BIOFLOW V Investigators
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1016/j.jcin.2020.02.019
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1876-7605
ExternalDocumentID 32499026
Genre Multicenter Study
Comparative Study
Randomized Controlled Trial
Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
--K
--M
.1-
.FO
.~1
0R~
0SF
18M
1B1
1P~
1~.
4.4
457
4G.
53G
5GY
5VS
7-5
8P~
AACTN
AAEDW
AAFTH
AAIKJ
AALRI
AAOAW
AAQFI
AAXUO
ABBQC
ABFRF
ABJNI
ABMAC
ABMZM
ABVKL
ACGFO
ACGFS
ADBBV
ADEZE
ADVLN
AEFWE
AEKER
AEVXI
AEXQZ
AFCTW
AFETI
AFJKZ
AFRHN
AFTJW
AGYEJ
AITUG
AJOXV
AJRQY
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
BAWUL
BLXMC
CGR
CS3
CUY
CVF
DIK
EBS
ECM
EIF
F5P
FDB
FEDTE
FNPLU
GBLVA
HVGLF
IXB
J1W
M41
MO0
N9A
NPM
O-L
O9-
OAUVE
OA~
OK1
OL0
P-8
P-9
P2P
PC.
Q38
ROL
SDF
SEL
SES
SSZ
T5K
W8F
Z5R
7X8
AAYWO
AGCQF
ID FETCH-LOGICAL-p211t-241768c3c4c88e8da48d077b9f5544ae54aa2ae0a7ef32083a5800575cf6af853
ISSN 1876-7605
IngestDate Fri Jul 11 09:17:37 EDT 2025
Wed Feb 19 02:30:10 EST 2025
IsDoiOpenAccess false
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 11
Keywords percutaneous coronary intervention
bioresorbable polymer
ultrathin-strut drug-eluting stent
Language English
License Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p211t-241768c3c4c88e8da48d077b9f5544ae54aa2ae0a7ef32083a5800575cf6af853
Notes ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
PMID 32499026
PQID 2410351932
PQPubID 23479
ParticipantIDs proquest_miscellaneous_2410351932
pubmed_primary_32499026
PublicationCentury 2000
PublicationDate 2020-06-08
20200608
PublicationDateYYYYMMDD 2020-06-08
PublicationDate_xml – month: 06
  year: 2020
  text: 2020-06-08
  day: 08
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle JACC. Cardiovascular interventions
PublicationTitleAlternate JACC Cardiovasc Interv
PublicationYear 2020
References 32499027 - JACC Cardiovasc Interv. 2020 Jun 8;13(11):1354-1356
References_xml – reference: 32499027 - JACC Cardiovasc Interv. 2020 Jun 8;13(11):1354-1356
SSID ssj0060972
Score 2.537565
Snippet The aim of this study was to compare late-term clinical outcomes among patients treated with ultrathin-strut (60-μm) bioresorbable-polymer sirolimus-eluting...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 1343
SubjectTerms Absorbable Implants
Aged
Cardiovascular Agents - administration & dosage
Cardiovascular Agents - adverse effects
Coronary Artery Disease - diagnostic imaging
Coronary Artery Disease - mortality
Coronary Artery Disease - therapy
Drug-Eluting Stents
Everolimus - administration & dosage
Everolimus - adverse effects
Female
Humans
Male
Middle Aged
Percutaneous Coronary Intervention - adverse effects
Percutaneous Coronary Intervention - instrumentation
Percutaneous Coronary Intervention - mortality
Prospective Studies
Prosthesis Design
Risk Factors
Sirolimus - administration & dosage
Sirolimus - adverse effects
Time Factors
Treatment Outcome
Title Ultrathin Bioresorbable-Polymer Sirolimus-Eluting Stents Versus Thin Durable-Polymer Everolimus-Eluting Stents for Coronary Revascularization: 3-Year Outcomes From the Randomized BIOFLOW V Trial
URI https://www.ncbi.nlm.nih.gov/pubmed/32499026
https://www.proquest.com/docview/2410351932
Volume 13
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLbKkBAviPvGTUbirXKV-4W3rWvZoFvRaEd5ihzHYZnWZGoTJPrz-Cf8E86Jk6ZdizR4SRtLTt2cT8fn9h0T8k7zDUdqnmBWLHyMVgnGHVswGYeu9EJHEzpyh09OnaOx9XFiT1qt3ytVS0UedsRiK6_kf6QKYyBXZMn-g2SXD4UB-A7yhStIGK63kvH4CnvLXiQpHikJfnM2C5EJxT5nVz-nctb-kuCZPNNiznq4jLL3dslowyhZMS8P7WwfFrO1ST14DdtnYUViFzseYKXdmayLWCsmJ8YWTPYNGwMNixz-rpyDWVyRV854GmXTZAHm7cHxsD8Yfm2ft0f4itas4_1ut4M1KGslsitVmU3mCZ634DVL_kcSNYyKTxmWGqgKYIG7XpP5OoTFq0wA0je_XyxB_QFPVOJMfajdGJMZVai4CooYWlm8tarHQckz19FUwlxuGauVv7kKcn1Fleum6h-1sceocMdl51Ik2EDX0Mqmr5XiX2vofToM-uPBIBj1JqM75K4BngzuHceTg9pYcLB7EsYE6rVVvC5VgnjzF_7uBZXW0OgheVC5MXRfYfIRacn0Mbl3UhVqPCG_ltCkW6FJN6BJFciogiZFaNIb0KSb0KxnATRpDU26Ac33VAGT1sCkCEwKwKQNMGkFTHpOS2A-JeN-b9Q9YtVxIeza0PWcgS0KvrMwhSU8T3oRt7xIc93Qj8Fktri0Lc4NLjXuytg0wPXgtodcbFvEDo_BbH1GdtIslbuEhj6oMNP0dUNqVuh5HG6c0Ix9uNF5HO2Rt7UgAlDHmGPjqcyKeQCLwNw8eEV75LmSUHCt-sYE4LuA7Wc4L24x-yW53-D6FdnJZ4V8DeZvHr4pAfQH_Si6Vw
linkProvider Elsevier
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Ultrathin+Bioresorbable-Polymer+Sirolimus-Eluting+Stents+Versus+Thin+Durable-Polymer+Everolimus-Eluting+Stents+for+Coronary+Revascularization%3A+3-Year+Outcomes+From+the+Randomized+BIOFLOW+V+Trial&rft.jtitle=JACC.+Cardiovascular+interventions&rft.au=Kandzari%2C+David+E&rft.au=Koolen%2C+Jacques+J&rft.au=Doros%2C+Gheorghe&rft.au=Garcia-Garcia%2C+Hector+M&rft.date=2020-06-08&rft.issn=1876-7605&rft.eissn=1876-7605&rft.volume=13&rft.issue=11&rft.spage=1343&rft_id=info:doi/10.1016%2Fj.jcin.2020.02.019&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1876-7605&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1876-7605&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1876-7605&client=summon