HPLC method for identification and quantification of benzimidazole derivatives in antiparasitic drugs
The subject of the study was to develop a versatile HPLC system for identification and determination of four benzimidazole derivatives in the antiparasitic drugs. The tests covered: Zentel, Panacur, Vermox tablets and Systamex suspension. A satisfactory separation was obtained using the Nucleosil C8...
Saved in:
Published in | Acta Poloniae pharmaceutica Vol. 68; no. 6; p. 823 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Poland
01.11.2011
|
Subjects | |
Online Access | Get full text |
ISSN | 0001-6837 |
Cover
Loading…
Abstract | The subject of the study was to develop a versatile HPLC system for identification and determination of four benzimidazole derivatives in the antiparasitic drugs. The tests covered: Zentel, Panacur, Vermox tablets and Systamex suspension. A satisfactory separation was obtained using the Nucleosil C8 column in the gradient system composed of mobile phase A: 85% orthophosphoric acid / water / acetonitrile in 0.05:75:25, v/v/v ratio, and mobile phase B: 85% orthophosphoric acid / water / acetonitrile in 0.05:50:50, v/v/v ratio. Both phases were adjusted to pH = 4.5 with 15% sodium hydroxide solution. A detection at 288 nm for oxfendazole and 254 nm for albendazole, fenbendazole and mebendazole was applied. The correlation coefficients in the range 0,9997 - 0,9999 proved that the calibration curves were linear. The method was validated in terms of selectivity, accuracy and precision. |
---|---|
AbstractList | The subject of the study was to develop a versatile HPLC system for identification and determination of four benzimidazole derivatives in the antiparasitic drugs. The tests covered: Zentel, Panacur, Vermox tablets and Systamex suspension. A satisfactory separation was obtained using the Nucleosil C8 column in the gradient system composed of mobile phase A: 85% orthophosphoric acid / water / acetonitrile in 0.05:75:25, v/v/v ratio, and mobile phase B: 85% orthophosphoric acid / water / acetonitrile in 0.05:50:50, v/v/v ratio. Both phases were adjusted to pH = 4.5 with 15% sodium hydroxide solution. A detection at 288 nm for oxfendazole and 254 nm for albendazole, fenbendazole and mebendazole was applied. The correlation coefficients in the range 0,9997 - 0,9999 proved that the calibration curves were linear. The method was validated in terms of selectivity, accuracy and precision.The subject of the study was to develop a versatile HPLC system for identification and determination of four benzimidazole derivatives in the antiparasitic drugs. The tests covered: Zentel, Panacur, Vermox tablets and Systamex suspension. A satisfactory separation was obtained using the Nucleosil C8 column in the gradient system composed of mobile phase A: 85% orthophosphoric acid / water / acetonitrile in 0.05:75:25, v/v/v ratio, and mobile phase B: 85% orthophosphoric acid / water / acetonitrile in 0.05:50:50, v/v/v ratio. Both phases were adjusted to pH = 4.5 with 15% sodium hydroxide solution. A detection at 288 nm for oxfendazole and 254 nm for albendazole, fenbendazole and mebendazole was applied. The correlation coefficients in the range 0,9997 - 0,9999 proved that the calibration curves were linear. The method was validated in terms of selectivity, accuracy and precision. The subject of the study was to develop a versatile HPLC system for identification and determination of four benzimidazole derivatives in the antiparasitic drugs. The tests covered: Zentel, Panacur, Vermox tablets and Systamex suspension. A satisfactory separation was obtained using the Nucleosil C8 column in the gradient system composed of mobile phase A: 85% orthophosphoric acid / water / acetonitrile in 0.05:75:25, v/v/v ratio, and mobile phase B: 85% orthophosphoric acid / water / acetonitrile in 0.05:50:50, v/v/v ratio. Both phases were adjusted to pH = 4.5 with 15% sodium hydroxide solution. A detection at 288 nm for oxfendazole and 254 nm for albendazole, fenbendazole and mebendazole was applied. The correlation coefficients in the range 0,9997 - 0,9999 proved that the calibration curves were linear. The method was validated in terms of selectivity, accuracy and precision. |
Author | Podolska, Marzena Białecka, Wanda Kulik, Anna Mazurek, Aleksander Kwiatkowska-Puchniarz, Barbara |
Author_xml | – sequence: 1 givenname: Anna surname: Kulik fullname: Kulik, Anna email: akulik@il.waw.pl organization: Department of Basic and Applied Pharmacy, National Medicines Institute, 30/34 Chełmska St., 00-725 Warszawa, Poland. akulik@il.waw.pl – sequence: 2 givenname: Wanda surname: Białecka fullname: Białecka, Wanda – sequence: 3 givenname: Marzena surname: Podolska fullname: Podolska, Marzena – sequence: 4 givenname: Barbara surname: Kwiatkowska-Puchniarz fullname: Kwiatkowska-Puchniarz, Barbara – sequence: 5 givenname: Aleksander surname: Mazurek fullname: Mazurek, Aleksander |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/22125945$$D View this record in MEDLINE/PubMed |
BookMark | eNpNUE1LwzAYzmHi5txfkNw8FZIsH81RhjphoAc9l6R5o5E26Zp04H69Eyd4eng-D88VmsUUYYYWhBBayXqt5miV8-eJEsGVpvQSzRmjTGguFgi2L7sN7qF8JId9GnFwEEvwoTUlpIhNdHg_mf9S8thCPIY-OHNMHWAHYzicvANkHH4qJQxmNDmU0GI3Tu_5Gl1402VYnXGJ3h7uXzfbavf8-LS521UDo6RUWljFdMsJgRqodMpob5UDUitwkoqWca9qC8bWzAsura2lFa1VSkqhmVsv0e3v7jCm_QS5NH3ILXSdiZCm3GiiKOdS6VPy5pycbA-uGcbQm_Gr-Xtm_Q2U2mLt |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM 7X8 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Pharmacy, Therapeutics, & Pharmacology |
ExternalDocumentID | 22125945 |
Genre | Journal Article |
GroupedDBID | 23M 3EA 53G 5GY ABMXE ADBBV AENEX ALMA_UNASSIGNED_HOLDINGS BAWUL CGR CUY CVF DIK ECM EIF EN8 F5P GROUPED_DOAJ L7B NPM OK1 P6G TR2 Y2W 7X8 |
ID | FETCH-LOGICAL-p210t-95b729c400e8e16d7a9fb7de087ed615c24f78beab82f546bb86b5cb7766592d3 |
ISSN | 0001-6837 |
IngestDate | Thu Jul 10 22:47:06 EDT 2025 Sat Sep 28 08:00:16 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p210t-95b729c400e8e16d7a9fb7de087ed615c24f78beab82f546bb86b5cb7766592d3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PMID | 22125945 |
PQID | 907144679 |
PQPubID | 23479 |
ParticipantIDs | proquest_miscellaneous_907144679 pubmed_primary_22125945 |
PublicationCentury | 2000 |
PublicationDate | 2011-11-01 |
PublicationDateYYYYMMDD | 2011-11-01 |
PublicationDate_xml | – month: 11 year: 2011 text: 2011-11-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | Poland |
PublicationPlace_xml | – name: Poland |
PublicationTitle | Acta Poloniae pharmaceutica |
PublicationTitleAlternate | Acta Pol Pharm |
PublicationYear | 2011 |
SSID | ssj0000547911 |
Score | 1.915452 |
Snippet | The subject of the study was to develop a versatile HPLC system for identification and determination of four benzimidazole derivatives in the antiparasitic... |
SourceID | proquest pubmed |
SourceType | Aggregation Database Index Database |
StartPage | 823 |
SubjectTerms | Albendazole - analysis Antiparkinson Agents - analysis Benzimidazoles - analysis Buffers Calibration Chemistry, Pharmaceutical Chromatography, High Pressure Liquid - standards Fenbendazole - analysis Hydrogen-Ion Concentration Mebendazole - analysis Reference Standards Reproducibility of Results Solvents - chemistry |
Title | HPLC method for identification and quantification of benzimidazole derivatives in antiparasitic drugs |
URI | https://www.ncbi.nlm.nih.gov/pubmed/22125945 https://www.proquest.com/docview/907144679 |
Volume | 68 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Jb9NAFB6lPXFB7JRNc6C9pEbxPnNBQqFVoGnxwRG5WbNZtVLskNhUza_njceJJxKI5WJZs9jS-8bPb38IvWU09iNJqENHASgonsgdSpTn0JBS4SspRkwnCl9eRZNZ8HkezgeD91bUUlPzd2Lzy7yS_0EVxgBXnSX7D8juHgoDcA_4whUQhutfYTxJpuOuB3QbLljILvbHoKpt4t8bZg-BaMhVuSm-FZJtqjZpatX2N_vRBmYN9WJdDVxHcomhXDWdGX1bp1bUTIfMASNgari8tuzhvU_opliYUMmyV_YLdjwOj4mnxKKVVr8yyxSQgGp8szYTl2y1Uf3Gi1s4OovqFmadpNHlZmHe8pPYRgsdNbczWmwZsetExNR72TLiiFgHzuaqxKQk71fLvvqSnc-m0yw9m6cH6MB3deeEj58udhY2EEZj6nYtE83bfq9GtOJE-gDd7_QA_MGA-hANVPkInSSGonenOO3z4tan-AQnfYnxu8dIaeSxQR4D8ngfeQzUxfvI4yrHe8hjC3lc6C0W8rhF_gmanZ-l44nTNcxwlqC51_CBcdCVBLBlRZQbyZjRnMdSjUisJIiuwgvymHDFOPHyMIg4JxEPBY_jSHvXpf8UHZZVqZ4j7OWx70ognIKFKieMjAQok3koQZyRXnSE8JaSGTAk7WVipaqadUZ1Shz8fukRemYonC1N4ZTMAzkppEH44s-bX6J7_bl5hQ7rVaNeg_hX8zctyj8BFoBnow |
linkProvider | Flying Publisher |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=HPLC+method+for+identification+and+quantification+of+benzimidazole+derivatives+in+antiparasitic+drugs&rft.jtitle=Acta+Poloniae+pharmaceutica&rft.au=Kulik%2C+Anna&rft.au=Bia%C5%82ecka%2C+Wanda&rft.au=Podolska%2C+Marzena&rft.au=Kwiatkowska-Puchniarz%2C+Barbara&rft.date=2011-11-01&rft.issn=0001-6837&rft.volume=68&rft.issue=6&rft.spage=823&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0001-6837&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0001-6837&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0001-6837&client=summon |