Computation of the equivalent airway resistance: a comparison with routine evaluations of plethysmographic measurements

Equivalent (effective) values of airway resistance were determined for total breaths, inspiration and expiration in spontaneously breathing patients by means of an off-line processing system. An improvement in the alveolar pressure determination was achieved by subtracting thermal pressure drifts of...

Full description

Saved in:
Bibliographic Details
Published inRespiration Vol. 36; no. 2; p. 64
Main Authors Hantos, Z, Galgóczy, G, Daróczy, B, Dombos, K
Format Journal Article
LanguageEnglish
Published Switzerland 1978
Subjects
Online AccessGet more information

Cover

Loading…
Abstract Equivalent (effective) values of airway resistance were determined for total breaths, inspiration and expiration in spontaneously breathing patients by means of an off-line processing system. An improvement in the alveolar pressure determination was achieved by subtracting thermal pressure drifts of the pressure plethysmograph and by taking into account instantaneous values of the intrathoracic gas volume. Equivalent resistance values were compared with the results of several simulated routine evaluations. It was found that the equivalent resistance is best approximated by the graphical procedure using average pressure points at +/- 0.5 liter/sec flow levels.
AbstractList Equivalent (effective) values of airway resistance were determined for total breaths, inspiration and expiration in spontaneously breathing patients by means of an off-line processing system. An improvement in the alveolar pressure determination was achieved by subtracting thermal pressure drifts of the pressure plethysmograph and by taking into account instantaneous values of the intrathoracic gas volume. Equivalent resistance values were compared with the results of several simulated routine evaluations. It was found that the equivalent resistance is best approximated by the graphical procedure using average pressure points at +/- 0.5 liter/sec flow levels.
Author Dombos, K
Hantos, Z
Daróczy, B
Galgóczy, G
Author_xml – sequence: 1
  givenname: Z
  surname: Hantos
  fullname: Hantos, Z
– sequence: 2
  givenname: G
  surname: Galgóczy
  fullname: Galgóczy, G
– sequence: 3
  givenname: B
  surname: Daróczy
  fullname: Daróczy, B
– sequence: 4
  givenname: K
  surname: Dombos
  fullname: Dombos, K
BackLink https://www.ncbi.nlm.nih.gov/pubmed/663423$$D View this record in MEDLINE/PubMed
BookMark eNotjztPwzAUhT2UR1sY2Bn8BwJ-NI7DhiJeUiWW7tVNck2M8sJ2iPLvMZTpDEffp3M2ZNUPPRJyw9kd52l-zxjjucyFXpE1YyJNslzyS7Lx_jM2qdbigpwrJXdCrslcDN04BQh26OlgaGiQ4tdkv6HFPlCwboaFOvTWB-grfKBAq4iAsz4Ssw0NdcMUbB-5CE1_Jv-rGlsMzeK74cPB2NiKdgh-cthFsb8iZwZaj9f_uSWH56dD8Zrs31_eisd9MgqWhkSZGrWCTPGy0jtdlryOw7mulclASwVCZqpkRuYm1TGNURK1rpmBeDQTW3J70o5T2WF9HJ3twC3H033xAz-iXtk
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1159/000193928
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
ExternalDocumentID 663423
Genre Journal Article
Comparative Study
GroupedDBID ---
.GJ
.XZ
0R~
0~5
0~B
123
29P
30W
327
34G
36B
39C
3O.
3V.
4.4
53G
5RE
7RQ
7RV
7X7
88E
8AO
8FI
8FJ
8G5
8UI
AAWTL
AAYIC
ABJNI
ABPAZ
ABUWG
ACGFS
ACPSR
ADAGL
ADBBV
AENEX
AEYAO
AFJJK
AFKRA
AHMBA
ALDHI
ALIPV
ALMA_UNASSIGNED_HOLDINGS
APPQY
AZPMC
AZQEC
BENPR
BKEYQ
BPHCQ
BVXVI
C45
CAG
CCPQU
CGR
COF
CS3
CUY
CVF
CYUIP
DU5
DWQXO
E0A
EBS
ECM
EIF
EJD
EMB
EMOBN
EX3
F5P
FB.
FYUFA
GNUQQ
GUQSH
HMCUK
HZ~
IAO
IHR
IHW
ITC
IY7
KUZGX
L7B
M1P
M2O
N9A
NAPCQ
NPM
O1H
O9-
OVD
PQQKQ
PROAC
PSQYO
RIG
RKO
RXVBD
SV3
TEORI
UJ6
UKHRP
WOW
ZGI
ZXP
ID FETCH-LOGICAL-p205t-6fde86a761bc848bb1d63418d6f7a836a2376b0f39f58b0fff63e88d0fa58872
ISSN 0025-7931
IngestDate Sat Sep 28 08:46:19 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 2
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p205t-6fde86a761bc848bb1d63418d6f7a836a2376b0f39f58b0fff63e88d0fa58872
PMID 663423
ParticipantIDs pubmed_primary_663423
PublicationCentury 1900
PublicationDate 1978-00-00
PublicationDateYYYYMMDD 1978-01-01
PublicationDate_xml – year: 1978
  text: 1978-00-00
PublicationDecade 1970
PublicationPlace Switzerland
PublicationPlace_xml – name: Switzerland
PublicationTitle Respiration
PublicationTitleAlternate Respiration
PublicationYear 1978
SSID ssj0015882
Score 1.243951
Snippet Equivalent (effective) values of airway resistance were determined for total breaths, inspiration and expiration in spontaneously breathing patients by means...
SourceID pubmed
SourceType Index Database
StartPage 64
SubjectTerms Airway Resistance
Computers
Humans
Lung Diseases, Obstructive - physiopathology
Plethysmography, Whole Body
Pulmonary Alveoli - physiology
Title Computation of the equivalent airway resistance: a comparison with routine evaluations of plethysmographic measurements
URI https://www.ncbi.nlm.nih.gov/pubmed/663423
Volume 36
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1JT-MwFLbKohEXxDZilw_cUJg0i-1yY69AcBgViRuyHXtUiS5AEQL-PM95JjEdQMxc0tSWXMffF_f5rYRscQ0yqklMZITVUcakjVqm4FEiE22t5vAv64KTzy9Y-zI7vcqvGo2XMLpkpHb084dxJf-DKrQBri5K9h-QrQaFBrgHfOEKCMP1WxhjSYZK6Cv9M24fuvATped49-5RPm3DedrJiAAuBjbruvJgqYS9G8AMQdSs836X3h1DABQw7GFK667e7tXaxPtQpP3tjfWBQb_tKhPfv7N7nMibP84ov5_qZwyOCXTk7zoqG9DhoKdwlLNaN9Esc_VWuom3WAGXENPv836_xYQnnldJsHliOvO_9_S8hU6QIGu2MJI8wHbYK8EFwSnDwOWv-sZSa2PHBJngwm2OF07R4w1QuRBJVe0XHsAnpYK5_KpmMkOmcYSxI0kpmnTmyKw_U9A9JMg8aZj-Avlx7r0mFsljwBM6sBR4QmueUOQJrXmySyWtWUIdS6hnCQ1Y4oYaZwkNWbJEOsdHnYN25AtuRMMkzkcRs4URTHLWVFpkQqlmAc_XFAWzXIqUSedCpWKbtmwu4NNalhohithKWC-e_CST_UHfLBOqWZxwnYk4VXAEz4yCrwXXBUhkhYqlXCFLuGLXQ0yqco0rufpJ-xqZqfm1TqYsvMFmA8TBkdosgXsFVtxlfg
link.rule.ids 786
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Computation+of+the+equivalent+airway+resistance%3A+a+comparison+with+routine+evaluations+of+plethysmographic+measurements&rft.jtitle=Respiration&rft.au=Hantos%2C+Z&rft.au=Galg%C3%B3czy%2C+G&rft.au=Dar%C3%B3czy%2C+B&rft.au=Dombos%2C+K&rft.date=1978-01-01&rft.issn=0025-7931&rft.volume=36&rft.issue=2&rft.spage=64&rft_id=info:doi/10.1159%2F000193928&rft_id=info%3Apmid%2F663423&rft_id=info%3Apmid%2F663423&rft.externalDocID=663423
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0025-7931&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0025-7931&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0025-7931&client=summon