Evaluation of back muscle function based on EMG time-frequency spectrogram analysis
EMG has been extensively used to study function of back muscle, which plays an important role in the objective assessment of occupational low back pain, yet the inherent large variability of EMG signals across subjects produced by reasons already known or unknown may mask true biological differences...
Saved in:
Published in | Sheng wu yi xue gong cheng xue za zhi Vol. 23; no. 2; p. 271 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | Chinese |
Published |
China
01.04.2006
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | EMG has been extensively used to study function of back muscle, which plays an important role in the objective assessment of occupational low back pain, yet the inherent large variability of EMG signals across subjects produced by reasons already known or unknown may mask true biological differences. Some useful parameters abstracted from 8-channel EMG signal in time-frequency domain are used or proposed and calculated in this paper to decrease this variability, when comparing the possible difference between low back pain patients and normal control group. The calculation of instantaneous median frequency is improved to decrease the interruption of background noise, and different power densities in EMG time-frequency spectrogram are observed in two tested groups. |
---|---|
AbstractList | EMG has been extensively used to study function of back muscle, which plays an important role in the objective assessment of occupational low back pain, yet the inherent large variability of EMG signals across subjects produced by reasons already known or unknown may mask true biological differences. Some useful parameters abstracted from 8-channel EMG signal in time-frequency domain are used or proposed and calculated in this paper to decrease this variability, when comparing the possible difference between low back pain patients and normal control group. The calculation of instantaneous median frequency is improved to decrease the interruption of background noise, and different power densities in EMG time-frequency spectrogram are observed in two tested groups. |
Author | Hu, Yong Cao, Yuzhen Jin, Shijiu Chen, Cheng |
Author_xml | – sequence: 1 givenname: Yuzhen surname: Cao fullname: Cao, Yuzhen email: yzcao@tju.edu.cn organization: College of Precision Instrument & Opto-electronics Engineering Tianjin University, Tianjin 30072, China. yzcao@tju.edu.cn – sequence: 2 givenname: Cheng surname: Chen fullname: Chen, Cheng – sequence: 3 givenname: Yong surname: Hu fullname: Hu, Yong – sequence: 4 givenname: Shijiu surname: Jin fullname: Jin, Shijiu |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/16706345$$D View this record in MEDLINE/PubMed |
BookMark | eNo1j8tOwzAURL0ooqX0F5B_INK1Y18nS1SFgtSKBbCubvxAEYkT4gQpf0_FYzWjsxiduWGr2Ee_YhsBIDKthV6zXUpNDSALQCzya7YWaABzpTfspfqidqap6SPvA6_JfvBuTrb1PMzR_vCaknf8UqrTgU9N57Mw-s_ZR7vwNHg7jf37SB2nSO2SmnTLrgK1ye_-csveHqrX_WN2fD487e-P2SCkmjJXOkXSEBinXBlA5UpiHhDRClNqFNIEHdAWqCAHuChT7ZWyRolQmODklt397g5z3Xl3Hsamo3E5_7-T3w2aTO4 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
ExternalDocumentID | 16706345 |
Genre | English Abstract Journal Article |
GroupedDBID | --- -05 2B. 5XA 5XF 92F 92I ABJNI ACGFS ALMA_UNASSIGNED_HOLDINGS CCEZO CGR CIEJG CUY CVF CW9 ECM EIF F5P NPM RPM TCJ TGQ U1G U5O |
ID | FETCH-LOGICAL-p124t-d9d4a27a07d4d9f0434263f666c17956127f5f6c8640300670abe44c741f87fd2 |
ISSN | 1001-5515 |
IngestDate | Wed Feb 19 01:54:58 EST 2025 |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 2 |
Language | Chinese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p124t-d9d4a27a07d4d9f0434263f666c17956127f5f6c8640300670abe44c741f87fd2 |
PMID | 16706345 |
ParticipantIDs | pubmed_primary_16706345 |
PublicationCentury | 2000 |
PublicationDate | 2006-Apr |
PublicationDateYYYYMMDD | 2006-04-01 |
PublicationDate_xml | – month: 04 year: 2006 text: 2006-Apr |
PublicationDecade | 2000 |
PublicationPlace | China |
PublicationPlace_xml | – name: China |
PublicationTitle | Sheng wu yi xue gong cheng xue za zhi |
PublicationTitleAlternate | Sheng Wu Yi Xue Gong Cheng Xue Za Zhi |
PublicationYear | 2006 |
SSID | ssib002806683 ssib031740855 ssib051374463 ssib001104309 ssib023167930 ssj0042137 |
Score | 1.6896116 |
Snippet | EMG has been extensively used to study function of back muscle, which plays an important role in the objective assessment of occupational low back pain, yet... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 271 |
SubjectTerms | Back Electromyography Fourier Analysis Humans Low Back Pain - physiopathology Muscle, Skeletal - physiopathology Spectrum Analysis |
Title | Evaluation of back muscle function based on EMG time-frequency spectrogram analysis |
URI | https://www.ncbi.nlm.nih.gov/pubmed/16706345 |
Volume | 23 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JTsMwELVauHBBIPZNPnCLgprUznJEqFBVgkupBCfkOHFTUBdBI9F8PTN2moQKEHBJUttKFc_L-I0zCyHngVRAQ0Vks3bAbRYzzw45V3ZbOJGQIhTMeFvced0B6z3wh0ajV_NayubRhcy_jCv5j1ShDeSKUbJ_kGx5U2iAa5AvHEHCcPyVjDtlqm7kfPDUL9Y4e4NBFi5Xuh1XqRi_CHRub3QheVu9Gu_phaWjLI1_liWK5CR1stpPE9ypzazFyHrPEmuIdYmkbsSfubDydFR9xNCbro9ZnlbRZVdF7AeehxWC9MBp1dIziQz66eh5lK3uQ5TuK0Z1onMW8C9e160mlrjAkFtXlKbwSk1Is7GWkuP5wJpMismfe1fyZC-7mqQJFgOWQK3t2wDJYe1W3dAEqlURKxfzAYSVIQWkCjO_lZqOO22f6boBZo1nrsnGWj4z5p4t_n_FPtE85X6LbBYGBr00aNkmjTzdIf0KKXSqKCKFGqTQJVKoRgqFC0AK_YwUWkMKXSJllwyuO_dXXbsop2HPgMTN7TiMmXB90fJjFocKJgST9SuwXyVoZayS6iuuPBl4DDQ_xm-JKGFMAudUga9id4-sTaaT5IBQrHEmApdFvg8jnFYUCS_xuAxCR3CZyEOyb-bgaWZypjwtZ-fo255jslHB6oSsK3hJk1NgfPPoTAvzA9zUUCo |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+back+muscle+function+based+on+EMG+time-frequency+spectrogram+analysis&rft.jtitle=Sheng+wu+yi+xue+gong+cheng+xue+za+zhi&rft.au=Cao%2C+Yuzhen&rft.au=Chen%2C+Cheng&rft.au=Hu%2C+Yong&rft.au=Jin%2C+Shijiu&rft.date=2006-04-01&rft.issn=1001-5515&rft.volume=23&rft.issue=2&rft.spage=271&rft_id=info%3Apmid%2F16706345&rft_id=info%3Apmid%2F16706345&rft.externalDocID=16706345 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1001-5515&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1001-5515&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1001-5515&client=summon |