Method to calculate the energy consumption index of pump operation under variable working conditions

In order to evaluate the energy consumption of pump operation under variable working conditions rationally, state graph of pump operation based on pump characteristic curve and flow rate variety curve has been established in three dimensions. A model to calculate the energy consumption index of pump...

Full description

Saved in:
Bibliographic Details
Published inNong ye gong cheng xue bao Vol. 25; no. 3; pp. 46 - 49
Main Authors Tang, Yue, Qin, Wuxuae, Yuan, Shouqi
Format Journal Article
LanguageChinese
Published 01.03.2009
Online AccessGet full text

Cover

Loading…
More Information
Summary:In order to evaluate the energy consumption of pump operation under variable working conditions rationally, state graph of pump operation based on pump characteristic curve and flow rate variety curve has been established in three dimensions. A model to calculate the energy consumption index of pump operation under variable working conditions has been established, which can solve the problem of existent model. In the model, energy consumption of pump operation in a time-interval was calculate by a definite integral, product of water supply amount and head was calculate by a double integral. The energy consumption index of pump operation of a pump station was calculate by the model. The results showed that it can calculate the energy consumption of pump operation under variable working conditions rationally.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1002-6819