The Minimal Difference as an Individual Threshold to Examine the Utility of a Verification Bout in Determining V̇O 2max

A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses. This study used the test-retest reliability, mean, and individual differences between the highest V̇O 2 from the GXT (V̇O 2GXT ) and verificati...

Full description

Saved in:
Bibliographic Details
Published inMedicine and science in sports and exercise Vol. 55; no. 6; p. 1063
Main Authors Succi, Pasquale J, Benitez, Brian, Kwak, Minyoung, Bergstrom, Haley C
Format Journal Article
LanguageEnglish
Published United States 01.06.2023
Subjects
Online AccessGet more information

Cover

Loading…
Abstract A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses. This study used the test-retest reliability, mean, and individual differences between the highest V̇O 2 from the GXT (V̇O 2GXT ) and verification bout (V̇O 2verification ) to examine the efficacy of a verification bout in the determination of O 2max in healthy, recreationally trained, well-motivated men. Ten men (24 ± 4 yr) completed a GXT on a cycle ergometer followed by a submaximal verification bout to determine V̇O 2GXT and V̇O 2verification . After completion of the initial GXT, subjects rested for 5 min then performed the verification bout at 90% of the peak power output from the initial GXT. Analyses included a two-way repeated-measures ANOVA, intraclass correlation coefficients (ICC 2,1 ), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (COV). There was no test (test 1 vs test 2)-method (GXT vs verification) interaction ( P = 0.300) and no main effect for test ( P = 0.690), but there was a main effect for method ( P = 0.003). The V̇O 2GXT (46.0 mL⋅kg -1 ⋅min -1 ) was significantly greater than V̇O 2verification (43.9 mL⋅kg -1 ⋅min -1 ), collapsed across test. The V̇O 2GXT (ICC = 0.970, SEM = 1.63 mL⋅kg -1 ⋅min -1 , MD = 4.51 mL⋅kg -1 ⋅min -1 , COV = 3.54%) and the V̇O 2verification (ICC = 0.953, SEM = 1.87 mL⋅kg -1 ⋅min -1 , MD = 5.17 mL⋅kg -1 ⋅min -1 , COV = 4.25%) demonstrated "excellent" reliability. No subject exceeded the MD test-retest for V̇O 2GXT or V̇O 2verification . No subject had a V̇O 2verification that exceeded V̇O 2GXT by more than the MD, but two subjects had a V̇O 2GXT , which exceeded V̇O 2verification by more than the MD. The excellent reliability of V̇O 2GXT in addition to the examination of the individual differences between V̇O 2GXT and V̇O 2verification using the MD indicated that a standalone GXT was sufficient to determine V̇O 2max .
AbstractList A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses. This study used the test-retest reliability, mean, and individual differences between the highest V̇O 2 from the GXT (V̇O 2GXT ) and verification bout (V̇O 2verification ) to examine the efficacy of a verification bout in the determination of O 2max in healthy, recreationally trained, well-motivated men. Ten men (24 ± 4 yr) completed a GXT on a cycle ergometer followed by a submaximal verification bout to determine V̇O 2GXT and V̇O 2verification . After completion of the initial GXT, subjects rested for 5 min then performed the verification bout at 90% of the peak power output from the initial GXT. Analyses included a two-way repeated-measures ANOVA, intraclass correlation coefficients (ICC 2,1 ), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (COV). There was no test (test 1 vs test 2)-method (GXT vs verification) interaction ( P = 0.300) and no main effect for test ( P = 0.690), but there was a main effect for method ( P = 0.003). The V̇O 2GXT (46.0 mL⋅kg -1 ⋅min -1 ) was significantly greater than V̇O 2verification (43.9 mL⋅kg -1 ⋅min -1 ), collapsed across test. The V̇O 2GXT (ICC = 0.970, SEM = 1.63 mL⋅kg -1 ⋅min -1 , MD = 4.51 mL⋅kg -1 ⋅min -1 , COV = 3.54%) and the V̇O 2verification (ICC = 0.953, SEM = 1.87 mL⋅kg -1 ⋅min -1 , MD = 5.17 mL⋅kg -1 ⋅min -1 , COV = 4.25%) demonstrated "excellent" reliability. No subject exceeded the MD test-retest for V̇O 2GXT or V̇O 2verification . No subject had a V̇O 2verification that exceeded V̇O 2GXT by more than the MD, but two subjects had a V̇O 2GXT , which exceeded V̇O 2verification by more than the MD. The excellent reliability of V̇O 2GXT in addition to the examination of the individual differences between V̇O 2GXT and V̇O 2verification using the MD indicated that a standalone GXT was sufficient to determine V̇O 2max .
Author Kwak, Minyoung
Benitez, Brian
Succi, Pasquale J
Bergstrom, Haley C
Author_xml – sequence: 1
  givenname: Pasquale J
  surname: Succi
  fullname: Succi, Pasquale J
  organization: Department of Kinesiology and Health Promotion, University of Kentucky, Lexington, KY
– sequence: 2
  givenname: Brian
  surname: Benitez
  fullname: Benitez, Brian
– sequence: 3
  givenname: Minyoung
  surname: Kwak
  fullname: Kwak, Minyoung
– sequence: 4
  givenname: Haley C
  surname: Bergstrom
  fullname: Bergstrom, Haley C
BackLink https://www.ncbi.nlm.nih.gov/pubmed/36719651$$D View this record in MEDLINE/PubMed
BookMark eNpNUFtOwzAQtBCIPuAGCO0FUuy8nH5CW6BSq3407W-1SdbEKHGqxEXpCbgch8ISILEfuxrNzEozI3ZpGkOM3Qk-EX44fVhvtxP-bwLhyws2FFHAPQeiARt13bsjZBCIazYIYimmcSSGrE9LgrU2usYK5lopasnkBNgBGliaQn_o4uS4tGypK5uqANvAosdaGwLrzDurK23P0ChA2FOrlc7R6sbAU3OyoA3MyVLr9Nq8wf7rcwN-jf0Nu1JYdXT7e8ds97xIZ6_eavOynD2uvKPggnsiUVGWuZ0oqTgWKGgqOSKGSaZklIdFqLI4lzwLXU7JwwQpipF8kSASBv6Y3f_8PZ6ymorDsXVR2_PhrwL_Gzb8YDk
ContentType Journal Article
Copyright Copyright © 2023 by the American College of Sports Medicine.
Copyright_xml – notice: Copyright © 2023 by the American College of Sports Medicine.
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1249/MSS.0000000000003127
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Physical Therapy
EISSN 1530-0315
ExternalDocumentID 36719651
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
-ET
-~X
.-D
.L3
.XZ
.Z2
01R
0R~
1J1
2FS
354
40H
4Q1
4Q2
4Q3
5AM
5GY
5RE
5VS
71W
77Y
7O~
85S
9V3
AAAAV
AAAXR
AAFWJ
AAGIX
AAHPQ
AAIQE
AAJCS
AAMOA
AAMTA
AAQKA
AAQQT
AARTV
AASCR
AASOK
AAUEB
AAWTL
AAXQO
ABASU
ABBUW
ABDIG
ABJNI
ABNJN
ABPXF
ABVCZ
ABXVJ
ABXYN
ABZAD
ABZZY
ACDDN
ACDOF
ACEWG
ACGFO
ACGFS
ACIFK
ACILI
ACJBD
ACLDA
ACNCT
ACTAD
ACTHT
ACWDW
ACWRI
ACXJB
ACXNZ
ACZKN
ADEGP
ADGGA
ADGHP
ADHPY
ADNVM
ADUKH
AE3
AE6
AEBDS
AENEX
AFBFQ
AFDTB
AFEXH
AFMBP
AFNMH
AFPHX
AFSOK
AFUWQ
AFYGQ
AGINI
AHOMT
AHQNM
AHQVU
AHVBC
AHWXW
AIJEX
AINUH
AJCLO
AJEOO
AJIOK
AJNWD
AJZMW
AKCTQ
AKULP
ALKUP
ALMA_UNASSIGNED_HOLDINGS
ALMTX
AMJPA
AMKUR
AMNEI
AOHHW
AOQMC
ATPOU
BOYCO
BQLVK
C45
CGR
CS3
CUY
CVF
DIWNM
DU5
E.X
EBS
ECM
EEVPB
EIF
ERAAH
EX3
F2K
F2L
F2M
F2N
F5P
FCALG
FL-
FRP
FW0
GNXGY
GQDEL
H0~
HLJTE
HZ~
IKREB
IKYAY
IN~
IYOWL
JF9
JG8
JK3
JK8
K8S
KD2
KMI
L-C
MMDCI
MPPUT
MVM
NPM
N~6
N~7
N~B
O9-
OAG
OAH
OBZCC
ODMTH
OGKNY
OHH
OHYEH
OKBHI
OL1
OLG
OLH
OLL
OLU
OLV
OLY
OLZ
OPUJH
OPX
OVD
OVDLW
OVDNE
OVIDH
OVLEI
OVOZU
OWU
OWV
OWW
OWX
OWY
OWZ
OXXIT
P2P
QMB
R2J
RLZ
S4R
S4S
SJN
TEORI
TN5
TSPGW
UKR
V2I
VVN
W3M
WF8
WH7
WOQ
WOW
X3V
X3W
XXN
XYM
XZL
YFH
YNT
YOC
YOJ
YQT
YR5
ZB8
ZCA
ZFV
ZUP
~02
ID FETCH-LOGICAL-p1010-18f5bb18f8f7f0ada1e970aaa48bf75c4d4fb6c70b43157048ae56ae218aaea32
IngestDate Mon Jul 21 06:00:50 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 6
Language English
License Copyright © 2023 by the American College of Sports Medicine.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p1010-18f5bb18f8f7f0ada1e970aaa48bf75c4d4fb6c70b43157048ae56ae218aaea32
PMID 36719651
ParticipantIDs pubmed_primary_36719651
PublicationCentury 2000
PublicationDate 2023-06-01
PublicationDateYYYYMMDD 2023-06-01
PublicationDate_xml – month: 06
  year: 2023
  text: 2023-06-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Medicine and science in sports and exercise
PublicationTitleAlternate Med Sci Sports Exerc
PublicationYear 2023
SSID ssj0007331
Score 2.4168503
Snippet A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses....
SourceID pubmed
SourceType Index Database
StartPage 1063
SubjectTerms Exercise Test - methods
Humans
Male
Oxygen Consumption - physiology
Reproducibility of Results
Title The Minimal Difference as an Individual Threshold to Examine the Utility of a Verification Bout in Determining V̇O 2max
URI https://www.ncbi.nlm.nih.gov/pubmed/36719651
Volume 55
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JbtswECWcFghy6ZLuG-bQnAylorVQPjZGCqOFmwJxjNyCEU0WQmvZiFTUzQ_0t_oB_agOF1lC4KKLD4RAygSheRq94Sxk7KXMBnJOn_YApZgHsVA8wDTigciGXKKKUmnzKybv0_FZ_PY8Oe_1fnSilr7U-aG82ppX8j9SpT6Sq8mS_QfJbialDrom-VJLEqb2r2U8KcpiYXWXbkrGoqm7TG_-JtVqSgKrjJ_JMM3jNS4MtbSMsy4--5gM7M9oydpv4fWPTLxyUZI-cuEyZkdhdjAaHWTipD9Y4LrLaifeQW89EU2iEP25cv4I09sc7dQ6oaQsHIWtTGKnav1TR8rw4CuHvA56333FTy7Sv_xmdFR7_-XHqr5cWmSP0Wq57mbGIGqDrg5Vo4DDwJw80dXQrpCvR2JX3ZI9G239DpBRScKbnJ66-pT-F3FXh6ADjdXCYiNKhSmtyP88eq06dzO0w3bITjEHr5rdIs8EzHmYPl2TFvRq23L22G4zxTXDxhKc6R12y1sm8NrB7C7rqXKf7Tai3We3P_hXGqauEsU9tqYr8ACEFoCAFWAJLQBhA0Col-ABCARA8ACEpQaELgDBABCKEjoAhNnP7ydgwHefnb05no7GgT_KI1hxG_-T6STPqc200CHOkauhCBExznItEhnPY52nUoQ5EdpE0GcFVZKiIgKKqDAaPGA3ymWpHjEgG4VmCNM8UmmcST6UmjqSkMtEYp6Gj9lD9xgvVq5ey0XzgJ_8duQp22vR-Izd1KQg1HNim3X-wor0F3mNf6g
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+Minimal+Difference+as+an+Individual+Threshold+to+Examine+the+Utility+of+a+Verification+Bout+in+Determining+V%CC%87O+2max&rft.jtitle=Medicine+and+science+in+sports+and+exercise&rft.au=Succi%2C+Pasquale+J&rft.au=Benitez%2C+Brian&rft.au=Kwak%2C+Minyoung&rft.au=Bergstrom%2C+Haley+C&rft.date=2023-06-01&rft.eissn=1530-0315&rft.volume=55&rft.issue=6&rft.spage=1063&rft_id=info:doi/10.1249%2FMSS.0000000000003127&rft_id=info%3Apmid%2F36719651&rft_id=info%3Apmid%2F36719651&rft.externalDocID=36719651