The Minimal Difference as an Individual Threshold to Examine the Utility of a Verification Bout in Determining V̇O 2max
A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses. This study used the test-retest reliability, mean, and individual differences between the highest V̇O 2 from the GXT (V̇O 2GXT ) and verificati...
Saved in:
Published in | Medicine and science in sports and exercise Vol. 55; no. 6; p. 1063 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
United States
01.06.2023
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses. This study used the test-retest reliability, mean, and individual differences between the highest V̇O 2 from the GXT (V̇O 2GXT ) and verification bout (V̇O 2verification ) to examine the efficacy of a verification bout in the determination of O 2max in healthy, recreationally trained, well-motivated men.
Ten men (24 ± 4 yr) completed a GXT on a cycle ergometer followed by a submaximal verification bout to determine V̇O 2GXT and V̇O 2verification . After completion of the initial GXT, subjects rested for 5 min then performed the verification bout at 90% of the peak power output from the initial GXT. Analyses included a two-way repeated-measures ANOVA, intraclass correlation coefficients (ICC 2,1 ), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (COV).
There was no test (test 1 vs test 2)-method (GXT vs verification) interaction ( P = 0.300) and no main effect for test ( P = 0.690), but there was a main effect for method ( P = 0.003). The V̇O 2GXT (46.0 mL⋅kg -1 ⋅min -1 ) was significantly greater than V̇O 2verification (43.9 mL⋅kg -1 ⋅min -1 ), collapsed across test. The V̇O 2GXT (ICC = 0.970, SEM = 1.63 mL⋅kg -1 ⋅min -1 , MD = 4.51 mL⋅kg -1 ⋅min -1 , COV = 3.54%) and the V̇O 2verification (ICC = 0.953, SEM = 1.87 mL⋅kg -1 ⋅min -1 , MD = 5.17 mL⋅kg -1 ⋅min -1 , COV = 4.25%) demonstrated "excellent" reliability. No subject exceeded the MD test-retest for V̇O 2GXT or V̇O 2verification . No subject had a V̇O 2verification that exceeded V̇O 2GXT by more than the MD, but two subjects had a V̇O 2GXT , which exceeded V̇O 2verification by more than the MD.
The excellent reliability of V̇O 2GXT in addition to the examination of the individual differences between V̇O 2GXT and V̇O 2verification using the MD indicated that a standalone GXT was sufficient to determine V̇O 2max . |
---|---|
AbstractList | A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses. This study used the test-retest reliability, mean, and individual differences between the highest V̇O 2 from the GXT (V̇O 2GXT ) and verification bout (V̇O 2verification ) to examine the efficacy of a verification bout in the determination of O 2max in healthy, recreationally trained, well-motivated men.
Ten men (24 ± 4 yr) completed a GXT on a cycle ergometer followed by a submaximal verification bout to determine V̇O 2GXT and V̇O 2verification . After completion of the initial GXT, subjects rested for 5 min then performed the verification bout at 90% of the peak power output from the initial GXT. Analyses included a two-way repeated-measures ANOVA, intraclass correlation coefficients (ICC 2,1 ), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (COV).
There was no test (test 1 vs test 2)-method (GXT vs verification) interaction ( P = 0.300) and no main effect for test ( P = 0.690), but there was a main effect for method ( P = 0.003). The V̇O 2GXT (46.0 mL⋅kg -1 ⋅min -1 ) was significantly greater than V̇O 2verification (43.9 mL⋅kg -1 ⋅min -1 ), collapsed across test. The V̇O 2GXT (ICC = 0.970, SEM = 1.63 mL⋅kg -1 ⋅min -1 , MD = 4.51 mL⋅kg -1 ⋅min -1 , COV = 3.54%) and the V̇O 2verification (ICC = 0.953, SEM = 1.87 mL⋅kg -1 ⋅min -1 , MD = 5.17 mL⋅kg -1 ⋅min -1 , COV = 4.25%) demonstrated "excellent" reliability. No subject exceeded the MD test-retest for V̇O 2GXT or V̇O 2verification . No subject had a V̇O 2verification that exceeded V̇O 2GXT by more than the MD, but two subjects had a V̇O 2GXT , which exceeded V̇O 2verification by more than the MD.
The excellent reliability of V̇O 2GXT in addition to the examination of the individual differences between V̇O 2GXT and V̇O 2verification using the MD indicated that a standalone GXT was sufficient to determine V̇O 2max . |
Author | Kwak, Minyoung Benitez, Brian Succi, Pasquale J Bergstrom, Haley C |
Author_xml | – sequence: 1 givenname: Pasquale J surname: Succi fullname: Succi, Pasquale J organization: Department of Kinesiology and Health Promotion, University of Kentucky, Lexington, KY – sequence: 2 givenname: Brian surname: Benitez fullname: Benitez, Brian – sequence: 3 givenname: Minyoung surname: Kwak fullname: Kwak, Minyoung – sequence: 4 givenname: Haley C surname: Bergstrom fullname: Bergstrom, Haley C |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/36719651$$D View this record in MEDLINE/PubMed |
BookMark | eNpNUFtOwzAQtBCIPuAGCO0FUuy8nH5CW6BSq3407W-1SdbEKHGqxEXpCbgch8ISILEfuxrNzEozI3ZpGkOM3Qk-EX44fVhvtxP-bwLhyws2FFHAPQeiARt13bsjZBCIazYIYimmcSSGrE9LgrU2usYK5lopasnkBNgBGliaQn_o4uS4tGypK5uqANvAosdaGwLrzDurK23P0ChA2FOrlc7R6sbAU3OyoA3MyVLr9Nq8wf7rcwN-jf0Nu1JYdXT7e8ds97xIZ6_eavOynD2uvKPggnsiUVGWuZ0oqTgWKGgqOSKGSaZklIdFqLI4lzwLXU7JwwQpipF8kSASBv6Y3f_8PZ6ymorDsXVR2_PhrwL_Gzb8YDk |
ContentType | Journal Article |
Copyright | Copyright © 2023 by the American College of Sports Medicine. |
Copyright_xml | – notice: Copyright © 2023 by the American College of Sports Medicine. |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1249/MSS.0000000000003127 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine Physical Therapy |
EISSN | 1530-0315 |
ExternalDocumentID | 36719651 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | --- -ET -~X .-D .L3 .XZ .Z2 01R 0R~ 1J1 2FS 354 40H 4Q1 4Q2 4Q3 5AM 5GY 5RE 5VS 71W 77Y 7O~ 85S 9V3 AAAAV AAAXR AAFWJ AAGIX AAHPQ AAIQE AAJCS AAMOA AAMTA AAQKA AAQQT AARTV AASCR AASOK AAUEB AAWTL AAXQO ABASU ABBUW ABDIG ABJNI ABNJN ABPXF ABVCZ ABXVJ ABXYN ABZAD ABZZY ACDDN ACDOF ACEWG ACGFO ACGFS ACIFK ACILI ACJBD ACLDA ACNCT ACTAD ACTHT ACWDW ACWRI ACXJB ACXNZ ACZKN ADEGP ADGGA ADGHP ADHPY ADNVM ADUKH AE3 AE6 AEBDS AENEX AFBFQ AFDTB AFEXH AFMBP AFNMH AFPHX AFSOK AFUWQ AFYGQ AGINI AHOMT AHQNM AHQVU AHVBC AHWXW AIJEX AINUH AJCLO AJEOO AJIOK AJNWD AJZMW AKCTQ AKULP ALKUP ALMA_UNASSIGNED_HOLDINGS ALMTX AMJPA AMKUR AMNEI AOHHW AOQMC ATPOU BOYCO BQLVK C45 CGR CS3 CUY CVF DIWNM DU5 E.X EBS ECM EEVPB EIF ERAAH EX3 F2K F2L F2M F2N F5P FCALG FL- FRP FW0 GNXGY GQDEL H0~ HLJTE HZ~ IKREB IKYAY IN~ IYOWL JF9 JG8 JK3 JK8 K8S KD2 KMI L-C MMDCI MPPUT MVM NPM N~6 N~7 N~B O9- OAG OAH OBZCC ODMTH OGKNY OHH OHYEH OKBHI OL1 OLG OLH OLL OLU OLV OLY OLZ OPUJH OPX OVD OVDLW OVDNE OVIDH OVLEI OVOZU OWU OWV OWW OWX OWY OWZ OXXIT P2P QMB R2J RLZ S4R S4S SJN TEORI TN5 TSPGW UKR V2I VVN W3M WF8 WH7 WOQ WOW X3V X3W XXN XYM XZL YFH YNT YOC YOJ YQT YR5 ZB8 ZCA ZFV ZUP ~02 |
ID | FETCH-LOGICAL-p1010-18f5bb18f8f7f0ada1e970aaa48bf75c4d4fb6c70b43157048ae56ae218aaea32 |
IngestDate | Mon Jul 21 06:00:50 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
License | Copyright © 2023 by the American College of Sports Medicine. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-p1010-18f5bb18f8f7f0ada1e970aaa48bf75c4d4fb6c70b43157048ae56ae218aaea32 |
PMID | 36719651 |
ParticipantIDs | pubmed_primary_36719651 |
PublicationCentury | 2000 |
PublicationDate | 2023-06-01 |
PublicationDateYYYYMMDD | 2023-06-01 |
PublicationDate_xml | – month: 06 year: 2023 text: 2023-06-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Medicine and science in sports and exercise |
PublicationTitleAlternate | Med Sci Sports Exerc |
PublicationYear | 2023 |
SSID | ssj0007331 |
Score | 2.4168503 |
Snippet | A square-wave verification bout to confirm maximal oxygen uptake (V̇O 2max ) from a graded exercise test (GXT) has been recommended based on mean responses.... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 1063 |
SubjectTerms | Exercise Test - methods Humans Male Oxygen Consumption - physiology Reproducibility of Results |
Title | The Minimal Difference as an Individual Threshold to Examine the Utility of a Verification Bout in Determining V̇O 2max |
URI | https://www.ncbi.nlm.nih.gov/pubmed/36719651 |
Volume | 55 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JbtswECWcFghy6ZLuG-bQnAylorVQPjZGCqOFmwJxjNyCEU0WQmvZiFTUzQ_0t_oB_agOF1lC4KKLD4RAygSheRq94Sxk7KXMBnJOn_YApZgHsVA8wDTigciGXKKKUmnzKybv0_FZ_PY8Oe_1fnSilr7U-aG82ppX8j9SpT6Sq8mS_QfJbialDrom-VJLEqb2r2U8KcpiYXWXbkrGoqm7TG_-JtVqSgKrjJ_JMM3jNS4MtbSMsy4--5gM7M9oydpv4fWPTLxyUZI-cuEyZkdhdjAaHWTipD9Y4LrLaifeQW89EU2iEP25cv4I09sc7dQ6oaQsHIWtTGKnav1TR8rw4CuHvA56333FTy7Sv_xmdFR7_-XHqr5cWmSP0Wq57mbGIGqDrg5Vo4DDwJw80dXQrpCvR2JX3ZI9G239DpBRScKbnJ66-pT-F3FXh6ADjdXCYiNKhSmtyP88eq06dzO0w3bITjEHr5rdIs8EzHmYPl2TFvRq23L22G4zxTXDxhKc6R12y1sm8NrB7C7rqXKf7Tai3We3P_hXGqauEsU9tqYr8ACEFoCAFWAJLQBhA0Col-ABCARA8ACEpQaELgDBABCKEjoAhNnP7ydgwHefnb05no7GgT_KI1hxG_-T6STPqc200CHOkauhCBExznItEhnPY52nUoQ5EdpE0GcFVZKiIgKKqDAaPGA3ymWpHjEgG4VmCNM8UmmcST6UmjqSkMtEYp6Gj9lD9xgvVq5ey0XzgJ_8duQp22vR-Izd1KQg1HNim3X-wor0F3mNf6g |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+Minimal+Difference+as+an+Individual+Threshold+to+Examine+the+Utility+of+a+Verification+Bout+in+Determining+V%CC%87O+2max&rft.jtitle=Medicine+and+science+in+sports+and+exercise&rft.au=Succi%2C+Pasquale+J&rft.au=Benitez%2C+Brian&rft.au=Kwak%2C+Minyoung&rft.au=Bergstrom%2C+Haley+C&rft.date=2023-06-01&rft.eissn=1530-0315&rft.volume=55&rft.issue=6&rft.spage=1063&rft_id=info:doi/10.1249%2FMSS.0000000000003127&rft_id=info%3Apmid%2F36719651&rft_id=info%3Apmid%2F36719651&rft.externalDocID=36719651 |