Measurement of optic nerve head circulation: comparison of laser speckle and hydrogen clearance methods
Microcirculation in the optic nerve head (ONH) in the ocular fundus was measured noninvasively using the recently developed laser speckle circulation analyzer. Results were compared with capillary blood flow (CBF) measurements made by the hydrogen clearance method. The ONH blood flow of six normal r...
Saved in:
Published in | Japanese journal of ophthalmology Vol. 40; no. 3; p. 339 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Japan
01.01.1996
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | Microcirculation in the optic nerve head (ONH) in the ocular fundus was measured noninvasively using the recently developed laser speckle circulation analyzer. Results were compared with capillary blood flow (CBF) measurements made by the hydrogen clearance method. The ONH blood flow of six normal rabbits was measured simultaneously by both methods. Inhalation of 10% carbon dioxide (CO2) increased the CBF by 22% (hydrogen clearance method). Intravenous injection of endothelin-1 (ET-1) (10(-10) mol/kg) decreased the CBF by 19%. Significant correlations were found between the NB (normalized blur) value by the laser speckle method and CBF (r = 0.38, P < 0.05, n = 30) and also between the relative change of NB and CBF (r = 0.92, P < 0.01, n = 30) in the ONH. This indicates that evaluation of the NB change in the ONH is as accurate with the laser speckle method as with the hydrogen clearance method, giving a basis for the clinical application of the laser speckle method of measuring ONH circulation. |
---|---|
AbstractList | Microcirculation in the optic nerve head (ONH) in the ocular fundus was measured noninvasively using the recently developed laser speckle circulation analyzer. Results were compared with capillary blood flow (CBF) measurements made by the hydrogen clearance method. The ONH blood flow of six normal rabbits was measured simultaneously by both methods. Inhalation of 10% carbon dioxide (CO2) increased the CBF by 22% (hydrogen clearance method). Intravenous injection of endothelin-1 (ET-1) (10(-10) mol/kg) decreased the CBF by 19%. Significant correlations were found between the NB (normalized blur) value by the laser speckle method and CBF (r = 0.38, P < 0.05, n = 30) and also between the relative change of NB and CBF (r = 0.92, P < 0.01, n = 30) in the ONH. This indicates that evaluation of the NB change in the ONH is as accurate with the laser speckle method as with the hydrogen clearance method, giving a basis for the clinical application of the laser speckle method of measuring ONH circulation. |
Author | Fujii, H Azuma, I Utsumi, T Sugiyama, T |
Author_xml | – sequence: 1 givenname: T surname: Sugiyama fullname: Sugiyama, T organization: Department of Ophthalmology, Osaka Medical College, Japan – sequence: 2 givenname: T surname: Utsumi fullname: Utsumi, T – sequence: 3 givenname: I surname: Azuma fullname: Azuma, I – sequence: 4 givenname: H surname: Fujii fullname: Fujii, H |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/8988423$$D View this record in MEDLINE/PubMed |
BookMark | eNotj8tKxDAYRoOMjJ3RRxDyAoXc27qTwRuMuNH18Cf5O622SUlaYd5exVl9Z3E48G3IKsSAF6TghstSCGVWpGBM8FJzra_IJudPxpgSUqzJum7q-hcLcnxFyEvCEcNMY0vjNPeOBkzfSDsET12f3DLA3MdwR10cJ0h9juHPHSBjonlC9zUgheBpd_IpHjFQNyAkCA7piHMXfb4mly0MGW_OuyUfjw_vu-dy__b0srvfl0EYNZcGdWMrXzHHVeUcWucbZbnTyMFbLaWRHBvZ6spLkFrW2AqoOddGedZIK7bk9r87LXZEf5hSP0I6Hc6HxQ_SgVZ4 |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1613-2246 |
ExternalDocumentID | 8988423 |
Genre | Journal Article Comparative Study |
GroupedDBID | --- --K -5E -5G -BR -EM -Y2 -~C .55 .86 .GJ .VR 06C 06D 0R~ 0VY 1B1 1N0 1~5 203 29J 29~ 2J2 2JN 2JY 2KG 2KM 2LR 2P1 2VQ 2~H 30V 3O- 3V. 4.4 406 408 409 40D 40E 4G. 53G 5GY 5VS 67Z 6NX 7-5 7.U 7X7 88E 8AO 8FI 8FJ 8TC 8UJ 95- 95. 95~ 96X AAAVM AABHQ AAEDT AAFGU AAHNG AAIAL AAJBT AAJKR AALRI AANXM AANZL AAQFI AAQXK AARHV AARTL AASML AATNV AATVU AAUYE AAWCG AAXUO AAYIU AAYQN AAYTO ABAKF ABBBX ABBXA ABDZT ABECU ABFGW ABFTV ABHLI ABHQN ABJNI ABJOX ABKAS ABKCH ABKTR ABLJU ABMNI ABMQK ABNWP ABPLI ABQBU ABSXP ABTEG ABTKH ABTMW ABULA ABUWG ABWNU ABXPI ACAOD ACBMV ACBRV ACBYP ACDTI ACGFS ACHSB ACHXU ACIGE ACIPQ ACIUM ACKNC ACMDZ ACMLO ACNCT ACOKC ACOMO ACPRK ACTTH ACVWB ACWMK ACZOJ ADBBV ADHHG ADHIR ADIMF ADINQ ADKNI ADKPE ADMDM ADMUD ADOXG ADPHR ADRFC ADTPH ADURQ ADYFF ADZKW AEBTG AEFQL AEFTE AEGAL AEGNC AEJHL AEJRE AEKMD AEMSY AENEX AEOHA AEPYU AESKC AESTI AETLH AEVLU AEVTX AEXYK AFBBN AFKRA AFLOW AFNRJ AFQWF AFRAH AFWTZ AFZKB AGAYW AGDGC AGGBP AGJBK AGMZJ AGQEE AGQMX AGRTI AGWIL AGWZB AGYKE AHAVH AHBYD AHKAY AHMBA AHSBF AHYZX AIAKS AIGIU AIIXL AILAN AIMYW AITGF AJBLW AJDOV AJRNO AKMHD AKQUC ALMA_UNASSIGNED_HOLDINGS ALWAN AMKLP AMXSW AMYLF AMYQR AOCGG ARMRJ ASPBG AVWKF AXYYD AZFZN B-. BA0 BDATZ BENPR BGNMA BPHCQ BVXVI CAG CCPQU CGR COF CS3 CSCUP CUY CVF DDRTE DL5 DNIVK DPUIP DU5 EBD EBLON EBS ECM EIF EIOEI EJD EMOBN EN4 ESBYG F5P FDB FEDTE FERAY FFXSO FGOYB FIGPU FINBP FNLPD FRRFC FSGXE FWDCC FYUFA G-Y G-Z GGCAI GGRSB GJIRD GNWQR GQ6 GQ7 GQ8 GXS HF~ HG5 HG6 HLICF HMCUK HMJXF HQYDN HRMNR HVGLF HZ~ I09 IHE IJ- IKXTQ ITM IWAJR IXC IXE IZIGR IZQ I~X I~Z J-C J0Z JBSCW JCJTX JZLTJ KDC KOV KPH LLZTM M1P M41 M4Y MA- N2Q NB0 NPM NPVJJ NQ- NQJWS NU0 O9- O93 O9I O9J OAM P2P P9S PF0 PQQKQ PROAC PSQYO PT4 Q2X QOR QOS R2- R89 R9I RIG ROL RPX RPZ RRX RSV S16 S1Z S27 S37 S3B SAP SDH SDM SEW SHX SISQX SJYHP SMD SNE SNPRN SNX SOHCF SOJ SPISZ SRMVM SSLCW SSXJD SSZ STPWE SV3 SZ9 SZN T13 TKC TSG TSK TSV TT1 TUC U2A U9L UG4 UKHRP UNUBA UOJIU UTJUX UZXMN VC2 VFIZW W23 W48 WJK WK8 X7J X7M YLTOR Z45 Z7U Z87 ZGI ZMTXR ZOVNA ~A9 |
ID | FETCH-LOGICAL-n264t-6e59b7d70c147ccebcd94b1c5e1adb533631e93f57d3a3538ef2a811564d093b2 |
ISSN | 0021-5155 |
IngestDate | Thu May 23 23:03:04 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-n264t-6e59b7d70c147ccebcd94b1c5e1adb533631e93f57d3a3538ef2a811564d093b2 |
PMID | 8988423 |
ParticipantIDs | pubmed_primary_8988423 |
PublicationCentury | 1900 |
PublicationDate | 1996-01-01 |
PublicationDateYYYYMMDD | 1996-01-01 |
PublicationDate_xml | – month: 01 year: 1996 text: 1996-01-01 day: 01 |
PublicationDecade | 1990 |
PublicationPlace | Japan |
PublicationPlace_xml | – name: Japan |
PublicationTitle | Japanese journal of ophthalmology |
PublicationTitleAlternate | Jpn J Ophthalmol |
PublicationYear | 1996 |
SSID | ssj0004232 |
Score | 1.7860479 |
Snippet | Microcirculation in the optic nerve head (ONH) in the ocular fundus was measured noninvasively using the recently developed laser speckle circulation analyzer.... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 339 |
SubjectTerms | Administration, Inhalation Animals Blood Flow Velocity - drug effects Blood Flow Velocity - physiology Carbon Dioxide - administration & dosage Carbon Dioxide - pharmacology Endothelin-1 - administration & dosage Endothelin-1 - pharmacology Hydrogen - metabolism Injections, Intravenous Ion-Selective Electrodes Laser-Doppler Flowmetry - methods Microcirculation Optic Disk - blood supply Rabbits Reproducibility of Results |
Title | Measurement of optic nerve head circulation: comparison of laser speckle and hydrogen clearance methods |
URI | https://www.ncbi.nlm.nih.gov/pubmed/8988423 |
Volume | 40 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3PS-QwFA66onhZ1l_oris5eBsqZpL0x95kWZGF8aID3iRNUmfEacvYOehfv-8lmWlHdFEvpSShLfleki-ved8j5JjZ09jEvB-xhMlIcCWiVKYaBp6Tr7OJcT7dwWV8MRR_b-RN69B30SVNfqKfX40r-QyqUAa4YpTsB5BdPBQK4B7whSsgDNd3YTxoHXxI-qoa1VdLPMOIBND09HiqQ3ou3Pnrbs7BHtBmVHKuLf7cdf8QRk9mWsHLehpzSbhYAp9g-nGJwsLyimkru6ITVT1qRuphsuSjv5rdjZ_URC0dxR420EHjpaKz55lvtHDgns_ux202be-U8OeYF06JeZAAizB7jF9m_NwKzCFC_bru5Ou1moKR8c5Myr3GUQfFeuJgTLM0FT5G-b-VL2S0Q80qWU1SnAkv0aszj5_t86Aq7z96k6yH5i82G450XH8jX8NugZ556LfIii23ycYgnIfYIXcdC6BVQZ0FUGcBFC2AdizgF23xx7YOfxrwp4A_neNPF_jTgP8uGZ7_uf59EYXUGVEJDLeJYiuzPDHJqWYi0drm2mQiZ1papkwOFD_mzGa8kInhisOiZ4u-ShkqB8Hg5Hl_j3wpq9LuExpb2IMKqbKiKAQTMJBlHmfcCmsKLY06IHu-i25rr49yG_ru-1sVP8hmazOHZK2A4Wh_Ardr8iMHzD_c-lSY |
link.rule.ids | 786 |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Measurement+of+optic+nerve+head+circulation%3A+comparison+of+laser+speckle+and+hydrogen+clearance+methods&rft.jtitle=Japanese+journal+of+ophthalmology&rft.au=Sugiyama%2C+T&rft.au=Utsumi%2C+T&rft.au=Azuma%2C+I&rft.au=Fujii%2C+H&rft.date=1996-01-01&rft.issn=0021-5155&rft.eissn=1613-2246&rft.volume=40&rft.issue=3&rft.spage=339&rft_id=info%3Apmid%2F8988423&rft_id=info%3Apmid%2F8988423&rft.externalDocID=8988423 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0021-5155&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0021-5155&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0021-5155&client=summon |