가스터빈 기동장치 센서리스 속도제어로직 성능실험

The gas turbine static starter rotates the stationary synchronous machine by the interaction of the rotor and the stator. The detection from the initial position of the rotor has been an important issue to drive with optimum torque. Previously, the gas turbine starter was used by attaching the encod...

Full description

Saved in:
Bibliographic Details
Published in전기학회 논문지 P권, 66(2) Vol. 66P; no. 2; pp. 69 - 75
Main Authors 류호선(Hoseon Ryu), 문주영(jooyoung Moon), 이의택(Uitaek Lee), 이주현(Joohyun Lee), 강윤모(Yunmo Kang), 박만기(Manki Park)
Format Journal Article
LanguageKorean
Published 대한전기학회 2017
Subjects
Online AccessGet full text
ISSN1229-800X
2586-7792

Cover

Abstract The gas turbine static starter rotates the stationary synchronous machine by the interaction of the rotor and the stator. The detection from the initial position of the rotor has been an important issue to drive with optimum torque. Previously, the gas turbine starter was used by attaching the encoder to the synchronous machine, but the position and velocity of the rotor have been estimated by sensor-less method until recently due to the difficulty in attaching and detaching and damage caused by the shaft voltage noise. In this paper, Rotor initial(stationary state) position estimation, forced commutation control(speed less than 10%), and natural commutation control(speed more than 10%) method using magnetic flux with integrated terminal voltage were presented and the sensor-less speed control performance was verified. As a result of making and evaluating the 29 kVA synchronous machine and the starting device, the performance of each control mode was satisfactory. Furthermore, the applied technology is expected to be used for the development of the gas turbine starter of tens of MW class and the field application.
AbstractList The gas turbine static starter rotates the stationary synchronous machine by the interaction of the rotor and the stator. The detection from the initial position of the rotor has been an important issue to drive with optimum torque. Previously, the gas turbine starter was used by attaching the encoder to the synchronous machine, but the position and velocity of the rotor have been estimated by sensor-less method until recently due to the difficulty in attaching and detaching and damage caused by the shaft voltage noise. In this paper, Rotor initial(stationary state) position estimation, forced commutation control(speed less than 10%), and natural commutation control(speed more than 10%) method using magnetic flux with integrated terminal voltage were presented and the sensor-less speed control performance was verified. As a result of making and evaluating the 29 kVA synchronous machine and the starting device, the performance of each control mode was satisfactory. Furthermore, the applied technology is expected to be used for the development of the gas turbine starter of tens of MW class and the field application.
The gas turbine static starter rotates the stationary synchronous machine by the interaction of the rotor and the stator. The detection from the initial position of the rotor has been an important issue to drive with optimum torque. Previously, the gas turbine starter was used by attaching the encoder to the synchronous machine, but the position and velocity of the rotor have been estimated by sensor-less method until recently due to the difficulty in attaching and detaching and damage caused by the shaft voltage noise. In this paper, Rotor initial(stationary state) position estimation, forced commutation control(speed less than 10%), and natural commutation control(speed more than 10%) method using magnetic flux with integrated terminal voltage were presented and the sensor-less speed control performance was verified. As a result of making and evaluating the 29 kVA synchronous machine and the starting device, the performance of each control mode was satisfactory. Furthermore, the applied technology is expected to be used for the development of the gas turbine starter of tens of MW class and the field application. KCI Citation Count: 0
Author 박만기(Manki Park)
강윤모(Yunmo Kang)
이주현(Joohyun Lee)
류호선(Hoseon Ryu)
문주영(jooyoung Moon)
이의택(Uitaek Lee)
Author_xml – sequence: 1
  fullname: 류호선(Hoseon Ryu)
– sequence: 2
  fullname: 문주영(jooyoung Moon)
– sequence: 3
  fullname: 이의택(Uitaek Lee)
– sequence: 4
  fullname: 이주현(Joohyun Lee)
– sequence: 5
  fullname: 강윤모(Yunmo Kang)
– sequence: 6
  fullname: 박만기(Manki Park)
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002228713$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNpNjD1Lw0AAhg-pYK39D10cHAL3ldzdWGqr1WJBOrgduXxISE0l0cFNIYhUpJtWKKLQ6uJQwcGCv6i5_geDdXB6Xnge3nVQiHqRtwKK2OSWwZjABVBEGAuDQ3i0BspJEihIKbMIxqgIGvPppe6PF-k0m91U5l_TbPConyZ6Nqzo9Funo-z1PfcVfX2XDVL9PNL3n9nLSL9d5f4j60_07XjxMNwAq77dTbzyH0ug06h3artGq73TrFVbRiioMJRCnrAQsolyuc2pMDGilDvUURb1lSNcTLAjFMQ2pEoxBpnvCd8xhXKhw1xSAlvL2yj2ZegEsmcHvzzuyTCW1cNOUyLCEeZm3m4u2zBIzgIZuUlX7lX32xgihjgnFoOCwH9ddB4HJ54b2PI0H3Z8IQ_a23XIEOOYC_IDq4F5mQ
ContentType Journal Article
DBID DBRKI
TDB
JDI
ACYCR
DEWEY 620
621.3
620.11297
DatabaseName DBPIA - 디비피아
Nurimedia DBPIA Journals
KoreaScience
Korean Citation Index
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Engineering
DocumentTitleAlternate Performance Test of Sensorless Speed Control Logic for Gas Turbine Starter
DocumentTitle_FL Performance Test of Sensorless Speed Control Logic for Gas Turbine Starter
EISSN 2586-7792
EndPage 75
ExternalDocumentID oai_kci_go_kr_ARTI_1381285
JAKO201718836709305
NODE07178289
GroupedDBID .UV
ALMA_UNASSIGNED_HOLDINGS
DBRKI
TDB
JDI
ACYCR
ID FETCH-LOGICAL-k949-bb1e9611a3bd8a849521448c4cb64fbc9d232c9b02a04bb7707fe9fc59bd0c7d3
ISSN 1229-800X
IngestDate Wed Feb 07 01:48:25 EST 2024
Fri Dec 22 11:58:55 EST 2023
Thu Feb 06 13:06:07 EST 2025
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 2
Keywords Load commutated inverter
Sensorless speed control
Excitation system
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k949-bb1e9611a3bd8a849521448c4cb64fbc9d232c9b02a04bb7707fe9fc59bd0c7d3
Notes KISTI1.1003/JNL.JAKO201718836709305
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201718836709305&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
PageCount 7
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_1381285
kisti_ndsl_JAKO201718836709305
nurimedia_primary_NODE07178289
PublicationCentury 2000
PublicationDate 2017
PublicationDateYYYYMMDD 2017-01-01
PublicationDate_xml – year: 2017
  text: 2017
PublicationDecade 2010
PublicationTitle 전기학회 논문지 P권, 66(2)
PublicationTitleAlternate 전기학회논문지. The Transactions of the Korean Institute of Electrical Engineers. P
PublicationYear 2017
Publisher 대한전기학회
Publisher_xml – name: 대한전기학회
SSID ssib044763221
ssib005299917
ssib013785837
ssib053377038
ssib006781898
ssib036278838
ssib022234313
Score 1.9720101
Snippet The gas turbine static starter rotates the stationary synchronous machine by the interaction of the rotor and the stator. The detection from the initial...
SourceID nrf
kisti
nurimedia
SourceType Open Website
Open Access Repository
Publisher
StartPage 69
SubjectTerms 전기공학
Title 가스터빈 기동장치 센서리스 속도제어로직 성능실험
URI https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07178289
http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201718836709305&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002228713
Volume 66P
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 전기학회 논문지 P권, 2017, 66(2), , pp.69-75
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Na9RAFA-1F_UgfmL9KIs4J0nJxyR5c5zdTaktbS8rFDyEnXxIWdmVbXvxIAqLSEV60wpFFFq9eKjgwYJ_UTf9H3wzmU12peDHJTu8_PLmZSab997kzXuGcTejXhYz6phpECQm9TPbbPuuZbaZ59KYoUUbyI3Cyyv-wgO6uOatTZ15OBa1tLUp5uKnp-4r-Z9ZRRrOq9wl-w8zWzJFArZxfvGIM4zHv5pjEnJSt2SwQtggwAmnJGwSoJIY1kmdEYB7CgSaBPOEMYlmIeGebCCISVBDXdfQDdaQaO4T3ih5FyCfQFNzQhxSuKXQyNIndaouszWFB2iolrxtdRnX_UJdi8sCUlSIHtnImqnkXkqOME9Jjg1OQEkHnpK3LmVEmO7PmlNRJK2qDvrGKA5iqdeX3x0m4iNCVQZIPamj1Iwbc9WmN8UeewbVM-h-UDRuTUBKCVw9hogFu4IgoalGRzUKduBi-1SI5qKARWm70cJMsQNVaxHHYaj6rbVCySqa44GPrgybUD1FwRn9F3PG9EhRvkZbJEVpmclc4b_p8DKycpEvrUphbACVms9V-X3RCpXhjsvPwurd60jXYGyPcYCmW-V6224AHlSmK9o5AYx9YacUFZNTmX7oNQSoPNTO09Hdo78nnaB1NNu6fbT2zna3ZMkKfO-NmXCti8YF7XvVePFHumRMdXqXjfNjGTmvGPPHh8_z7f2TweHw6FXt-MfhcOd9_uEgP9qt5YOf-WBv-Pkrnq_lL98Mdwb5x7387ffhp738yws8_224fZC_3j95t3vVaM2HrcaCqUuNmB1GmSmEnTLfttuuSKANlHkykyDENBY-zUTMEnQ8YiYsp21RIfBOgyxlWewxkVhxkLjXjOlur5teN2opc7MARNujIGjCErDjxBKQ0DRgsWDWjDGrBiXqJhuPo1Oma8a4g6MVdeL1SKZ-l7-PelGnH6GDez-y0cJ2AEGz5WBGT4q8NNHKajOUyzNyEeXGn7q5aZyTlGI18ZYxvdnfSm-jfb0pZtWD8gtiu65W
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EA%B0%80%EC%8A%A4%ED%84%B0%EB%B9%88+%EA%B8%B0%EB%8F%99%EC%9E%A5%EC%B9%98+%EC%84%BC%EC%84%9C%EB%A6%AC%EC%8A%A4+%EC%86%8D%EB%8F%84%EC%A0%9C%EC%96%B4%EB%A1%9C%EC%A7%81+%EC%84%B1%EB%8A%A5%EC%8B%A4%ED%97%98&rft.jtitle=%EC%A0%84%EA%B8%B0%ED%95%99%ED%9A%8C%EB%85%BC%EB%AC%B8%EC%A7%80.+The+Transactions+of+the+Korean+Institute+of+Electrical+Engineers.+P&rft.au=%EB%A5%98%ED%98%B8%EC%84%A0&rft.au=%EB%AC%B8%EC%A3%BC%EC%98%81&rft.au=%EC%9D%B4%EC%9D%98%ED%83%9D&rft.au=%EC%9D%B4%EC%A3%BC%ED%98%84&rft.date=2017&rft.issn=1229-800X&rft.eissn=2586-7792&rft.volume=66&rft.issue=2&rft.spage=69&rft.epage=75&rft.externalDBID=n%2Fa&rft.externalDocID=JAKO201718836709305
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1229-800X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1229-800X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1229-800X&client=summon