장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구
Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are...
Saved in:
Published in | 방사선기술과학 Vol. 44; no. 6; pp. 607 - 613 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | Korean |
Published |
대한방사선과학회(구 대한방사선기술학회)
30.12.2021
KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY 대한방사선과학회 |
Subjects | |
Online Access | Get full text |
ISSN | 2288-3509 2384-1168 |
Cover
Abstract | Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter. |
---|---|
AbstractList | Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter. KCI Citation Count: 0 Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital detectors attached has been developed. High energy X-rays are used because pelvic areas require high image quality. In this case, X-rays are transmitted a lot in thin areas such as an ankle, and it is not suitable for diagnosing an image. Therefore, this study use copper filters made with 3D printers to increase image quality in the Long-bone inspection. A copper filter was manufactured in consideration of the overall thickness of the lower part. The experiment was conducted in anterior-posterior (AP) and lateral (LAT) positions, depending on the presence or absence of the filter. 5x5 pixels of region of interest (ROI) were selected from the pelvis, knee, and ankle areas. X-rays were irradiated under the conditions of 70 kVp and 40 mAs for AP, 80 kVp, and 63 mAs for lat when without filters, 90 kVp and 80 mAs for AP, 90 kVp and 100 mAs for lat when with filters. signal to noise ratio(SNR) ratio and contrast to noise (CNR) values were measured 1106.38, 14.34 before applying the filter and 1189.32, 70.43 after the filter. For the knee area, 650.44, 97.61 before applying the filter, and 1013.17, 444.24 after applying the filter. For the ankle area, 206.65, 23.68 before applying the filter and 993.50, 136.11 after applying the filter. In the Long-bone examination, SNR and CNR were greatly measured when the filter was applied, confirmed the availability of using the copper additional filter. |
Author | 한봉주(Bong-Ju Han) 서현수(Hyun-Soo Seo) 이영진(Young-Jin Lee) 김우영(Woo-Young Kim) 윤명성(Myeong-Seong Yoon) |
Author_xml | – sequence: 1 fullname: 김우영(Woo-Young Kim) – sequence: 2 fullname: 서현수(Hyun-Soo Seo) – sequence: 3 fullname: 한봉주(Bong-Ju Han) – sequence: 4 fullname: 윤명성(Myeong-Seong Yoon) – sequence: 5 fullname: 이영진(Young-Jin Lee) |
BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002796199$$DAccess content in National Research Foundation of Korea (NRF) |
BookMark | eNpNjLtKw1AAhoNUsNa-QxYHh8C555yx1Fu1UJDuh-Q0kZCaQNPFTSQPoGCpSFrq0KLQoV5x8Ina03cwWodO3w_fx79tFKI48jaMIsKcWBAyXsg34tzCFIgto5wkgQswQzZniBaNCz0cz9-ezPnrlf7M5l-zxfjb1IN3_fC87GXmmr2e6v6NTjMT75vLu3QxmS3T2eIxb0aZHt7-1vOP6WIyNZe9NFd6cG_qbJQf6fTF1P1ZbneMTd9pJ175nyWjeXjQrB5b9cZRrVqpW6EgwiICIOZQ7FPYIo7yfEagcJhyXYco6CrlIqwUJ1whm9rUZ45HiNPyGMOYKp_hkrG3uo06vgxVIGMn-ON5LMOOrJw1a1IIAJkt8nZ31YZB0g1k1Era8qRy2kAAQcARFQxiytladxm7sXTjOFRe1PU6kgAIAOI2wFRQ_ANHj5Ea |
ContentType | Journal Article |
Copyright | COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED |
Copyright_xml | – notice: COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED |
DBID | P5Y SSSTE JDI ACYCR |
DEWEY | 616.0757 |
DatabaseName | Kyobo Scholar Journals Scholar(스콜라) KoreaScience Korean Citation Index |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
DocumentTitleAlternate | A Study on the Usefulness of Copper Filters Made with 3D Printers in Longbone Examination Using Long Length Detector |
EISSN | 2384-1168 |
EndPage | 613 |
ExternalDocumentID | oai_kci_go_kr_ARTI_9901679 JAKO202108259613586 4010028703595 |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS P5Y SSSTE .UV JDI ACYCR |
ID | FETCH-LOGICAL-k949-49026a53f51d4acef6419a6cbba4c1bccb23cc848c27575f6ae44ade66335cf63 |
ISSN | 2288-3509 |
IngestDate | Sun Aug 18 03:10:32 EDT 2024 Fri Dec 22 12:03:33 EST 2023 Tue Feb 18 14:55:52 EST 2025 |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 6 |
Keywords | 3D Printer 장골 검출기 CNR Copper filament 부가필터 Additional filter 구리 필라멘트 대조도 대 잡음비 SNR Long-bone Long length detector 장골 신호 대 잡음비 3D 프린터 3D |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-k949-49026a53f51d4acef6419a6cbba4c1bccb23cc848c27575f6ae44ade66335cf63 |
Notes | KISTI1.1003/JNL.JAKO202108259613586 http://journal.iksrs.or.kr |
OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202108259613586&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
PageCount | 7 |
ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_9901679 kisti_ndsl_JAKO202108259613586 kyobo_bookcenter_4010028703595 |
PublicationCentury | 2000 |
PublicationDate | 2021-12-30 |
PublicationDateYYYYMMDD | 2021-12-30 |
PublicationDate_xml | – month: 12 year: 2021 text: 2021-12-30 day: 30 |
PublicationDecade | 2020 |
PublicationTitle | 방사선기술과학 |
PublicationTitleAlternate | Journal of radiological science and technology |
PublicationYear | 2021 |
Publisher | 대한방사선과학회(구 대한방사선기술학회) KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY 대한방사선과학회 |
Publisher_xml | – name: 대한방사선과학회(구 대한방사선기술학회) – name: KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY – name: 대한방사선과학회 |
SSID | ssib036278625 ssib053376989 ssib030194475 ssib023718648 |
Score | 1.7802676 |
Snippet | Long-bone examination is mainly used for inspection of the lower extremities. Recently, a long length detector (FXRD-1751S, VIEWORKS, Korea) with three digital... |
SourceID | nrf kisti kyobo |
SourceType | Open Website Open Access Repository Publisher |
StartPage | 607 |
SubjectTerms | 방사선과학 |
TableOfContents | 서론 Ⅱ. 대상 및 방법 Ⅲ. 결과 Ⅳ. 고찰 Ⅴ. 결론 |
Title | 장골 검출기를 이용한 장골 검사에서 3D 프린터로 제작한 구리 필터의 유용성 연구 |
URI | https://scholar.kyobobook.co.kr/article/detail/4010028703595 http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202108259613586&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002796199 |
Volume | 44 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | 방사선기술과학, 2021, 44(6), , pp.607-613 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb9NAELbanrggECDKo7IQPllBfqyd3aPzQKGo9NAiysnyru0KBWIpNIdyQAjlB4BEVYTSqhxagdRDeIoDvyhx_gMzG8dxC6KUi7Ov-XZ2xvuYjXdWUW7yGN4CERropzIokdixSpyHAfT4kBu2HYooxIPCS_fcxn2yuOaszcwtF75a6mzwW-LZH8-V_I9WIQ30iqdkT6HZHBQSIAz6hSdoGJ7_pGOtXtVYXfMcre5pFVvzqC5D8vsFyKu4GqvKFKpVIKWCRStVXdLVtAqRAU_zmFavacyB0vpJmNTSvKosVNbYOIUgnV3TJQjBONbkyiprGM3qNif4niH5khUxs1g3VORIfAngVfUsEzFzKMk8o2NWJdq0GZKdiqlnHGLxDLO4DEd8yMoIJi0CSs8oiAtS6CTFBrlNGM33TmQOywQDDGTMUView8L9QZKU5GCqyyurC1SZzCQelW2TVUHYoo3NTqu0kiQwiidHiDIhSdZByJJ1T7KFjoFb66XFjt7A7ewjFaF8xvrwNOrk8gGapc0IqVbwqT9Mkpwy2wOyTOlp0sh7LaLQqmxtkZe_iPGI0GTAQwSL5krRTw96TDe_o7Pp5GZZ0Jdtx2DFmXjsCTQbcYrTqju-GTlbobnj08vH_KQTA70Jw_SDR81nlVnbxGlv6Xl9Mr1YNqzD3Kn1D1MbQ3eXedy1ymDf53EwhMp4vSpeTznhFkxYtOse4e9mwhNYkbbacWFFunpOOZuZkqo3HhfOKzPN5ILyJN3dH3z5oA4-v0i_9wY_-sP9n2q68zV993G01VMLuS8P0-1Xaben2jV19KY7POiPuv3heyiz10t3X2PpwbfD4cGhOtrqQla681ZNe3sAlHY_qel2H3IvKqu366vVRim7UqXUZASvkzQsN3Ds2DFDEogodonJAldwHhBhciG4ZQtBCRVWGey42A0iQoIwArPEdkTs2peUuVbSii4rquuEVojeBm0qiAgDxmOD8LIwzSjiDuXzyoKUlN8Knz72F727y_ji4oYUA_051MUCKEIfdxPwS_So7R_R4bxyA2TrN8UjH33g4-964jfbPlj6d3z8P98tsysnoVxVzkx7zDVlbqPdia6DHbHBF-Tb8Qs4UuVX |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EC%9E%A5%EA%B3%A8+%EA%B2%80%EC%B6%9C%EA%B8%B0%EB%A5%BC+%EC%9D%B4%EC%9A%A9%ED%95%9C+%EC%9E%A5%EA%B3%A8+%EA%B2%80%EC%82%AC%EC%97%90%EC%84%9C+3D+%ED%94%84%EB%A6%B0%ED%84%B0%EB%A1%9C+%EC%A0%9C%EC%9E%91%ED%95%9C+%EA%B5%AC%EB%A6%AC+%ED%95%84%ED%84%B0%EC%9D%98+%EC%9C%A0%EC%9A%A9%EC%84%B1+%EC%97%B0%EA%B5%AC&rft.jtitle=%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B8%B0%EC%88%A0%EA%B3%BC%ED%95%99&rft.au=%EA%B9%80%EC%9A%B0%EC%98%81%28Woo-Young+Kim%29&rft.au=%EC%84%9C%ED%98%84%EC%88%98%28Hyun-Soo+Seo%29&rft.au=%ED%95%9C%EB%B4%89%EC%A3%BC%28Bong-Ju+Han%29&rft.au=%EC%9C%A4%EB%AA%85%EC%84%B1%28Myeong-Seong+Yoon%29&rft.date=2021-12-30&rft.pub=%EB%8C%80%ED%95%9C%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B3%BC%ED%95%99%ED%9A%8C%28%EA%B5%AC+%EB%8C%80%ED%95%9C%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B8%B0%EC%88%A0%ED%95%99%ED%9A%8C%29&rft.issn=2288-3509&rft.volume=44&rft.issue=6&rft.spage=607&rft.epage=613&rft.externalDocID=4010028703595 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2288-3509&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2288-3509&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2288-3509&client=summon |