대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선
The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic c...
Saved in:
Published in | 전기학회 논문지 P권, 66(4) Vol. 66P; no. 4; pp. 213 - 218 |
---|---|
Main Author | |
Format | Journal Article |
Language | Korean |
Published |
대한전기학회
2017
|
Subjects | |
Online Access | Get full text |
ISSN | 1229-800X 2586-7792 |
Cover
Abstract | The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully. |
---|---|
AbstractList | The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully. KCI Citation Count: 0 The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully. |
Author | 이태봉(Tae-Bong Lee) |
Author_xml | – sequence: 1 fullname: 이태봉(Tae-Bong Lee) |
BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002289448$$DAccess content in National Research Foundation of Korea (NRF) |
BookMark | eNpFkLtOwlAAhhujiYi8QxcHhyanpz2XjgRvKJHEMLid1J7WNGAxVAc3SDool9EETbkMGtAJdcHoE3FO30EQE6fvH758w7-hrAbVwF1RUhBRrBFiwVUlpUNoaRSA03UlE4b-GTBNgg0I9ZRSFe26fHwRgztVjhriuSveI9l8UuXXU9Iey1acRBPZ66qzj6HsP8tRJFpj2YtUGUfJfazKh6no15Pmp4zeVDHpym5jYYvhbdL5FoPJIiVex6IzVWeTWEbDTWXNsyuhm_ljWint7ZZyB1qhuJ_PZQta2TKpxrHFdQMDyBEGpsN1TAGClDjAdTxIkUe4ZzueZQOiO0SHnsExQAQhw8UOp9RIK9vLbFDzWNnxWdX2f3leZeUay56U8gzqJsLYmrtbS7fsh1c-C3hYYYfZoyIEOgHEQHh-H0Dg3wuua_6Fy32bXc6HXbthx8WdXUAgMQ2LGj--m5MT |
ContentType | Journal Article |
DBID | DBRKI TDB JDI ACYCR |
DEWEY | 620 621.3 620.11297 |
DatabaseName | DBPIA - 디비피아 DBPIA KoreaScience Korean Citation Index |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
DocumentTitleAlternate | Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors |
DocumentTitle_FL | Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors |
EISSN | 2586-7792 |
EndPage | 218 |
ExternalDocumentID | oai_kci_go_kr_ARTI_2145669 JAKO201707356122050 NODE07274398 |
GroupedDBID | .UV ALMA_UNASSIGNED_HOLDINGS DBRKI TDB JDI ACYCR M~E |
ID | FETCH-LOGICAL-k948-d69d13602d5604cd16805287c0ecf285f7dfacf9a071c712f3d6057553e6cd883 |
ISSN | 1229-800X |
IngestDate | Tue Nov 21 21:41:28 EST 2023 Fri Dec 22 11:59:03 EST 2023 Thu Feb 06 13:38:27 EST 2025 |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 4 |
Keywords | DC-link of power converter Fault diagnosis Initial ESRo Electrolytic capacitor ESR(equivalent serises resistance) |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-k948-d69d13602d5604cd16805287c0ecf285f7dfacf9a071c712f3d6057553e6cd883 |
Notes | KISTI1.1003/JNL.JAKO201707356122050 |
OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201707356122050&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
PageCount | 6 |
ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_2145669 kisti_ndsl_JAKO201707356122050 nurimedia_primary_NODE07274398 |
PublicationCentury | 2000 |
PublicationDate | 2017 |
PublicationDateYYYYMMDD | 2017-01-01 |
PublicationDate_xml | – year: 2017 text: 2017 |
PublicationDecade | 2010 |
PublicationTitle | 전기학회 논문지 P권, 66(4) |
PublicationTitleAlternate | 전기학회논문지. The Transactions of the Korean Institute of Electrical Engineers. P |
PublicationYear | 2017 |
Publisher | 대한전기학회 |
Publisher_xml | – name: 대한전기학회 |
SSID | ssib044763221 ssib005299917 ssib013785837 ssib053377038 ssib006781898 ssib036278838 ssib022234313 ssib012146194 |
Score | 1.971971 |
Snippet | The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include,... |
SourceID | nrf kisti nurimedia |
SourceType | Open Website Open Access Repository Publisher |
StartPage | 213 |
SubjectTerms | 전기공학 |
Title | 대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선 |
URI | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07274398 http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201707356122050&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002289448 |
Volume | 66P |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | 전기학회 논문지 P권, 2017, 66(4), , pp.213-218 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Nb9MwFI_GLnBBIEB8ThEiJ1SUOl_20U47jaFtHAraLUqTFE1FLRrbhQPapBxgH0ekgrqPw6YNTgUuQ_AXLe7_wHtOtmYSEoNLmr7Y78OO_X6v9bM17UHLjp1mmDgw-4UupuSQSjMmTgW3gnJiOwojdTbgzKw79cyennfmxy48L61aWl5qPore_DGv5H96FWjQr5gl-w89e8oUCHAP_QtX6GG4nquPjbowqI-LFeq-wbjBGVLYpEEh1AcS9wAoIok7BqN4I4hBbXxEobStCgl4DKQacuJUPQMevqLYhsh516A-lOaGsAyek-rItRBiK01EUZ9hTcUb2FDFm4ECfk5ihlCqAANUvIaqCKbkgrjqQ6WmqfT18YoWjDQQKJ5SVa9mCL8wOFfzxCgoxJUuQhUqNDeVVUoMN8ugXFlhKk05KifME5WZuuHYNMjLKQRyX9mQ226OUuQKRUXenJaSJ_ArZQDkG2FSEXi0k1r8xMq_t-SJpWpslPq0aLbzqFfyLYQwGBLmfO56FY041IUAh51xSK77tDTy7DPuxSohFVJ4rrP7hc_O1eomoFJAmpgDDwAUVzrOvK2Ppl2CUUEpvdgD1DaKuquWRx06Qq2IIAFmnk7jAHk8Wvqz3bbBR5ERCoQAwgM_opJQT0yG0A_joQVAcJ1FAH4XO8t4egVMgSU017iiXS7CMJ3nY-qqNtbuXtO62caK_PQ523mvy4PVbL-XfUvl2p4uf-4NNw7len-YDuRWTz_-viu39-VBmq0fyq1Ul_10-KGvy49H2fbKcO2HTL_q2aAne6tYOtt9N9z8le0MkFX25TDbPNKPB32Z7l7XGpP1hj9VKQ4kqbSZTSuxy-Kq5ZokhjDBjuKqi-eBUC8yk6hFqNPy4lYYtVgIsD3yqqRlxS6GQ46VuFEMTXZDG-90O8lNTQ9pkjDPaiaEQUwVghOtWnETJkfTSVxSNW9pE6q9gk78-mUwzZ_M4asI7hgPsyWmAwXuQ0MG7WghwA3i8fNFN2gvBhAGPw7w-AHXZcDltJ2DV_nuNUH5_bj9twJ3tEsoOP_N8a42vrS4nNwDFL7UnFDv1G-I_riP |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EB%8C%80%EC%9A%A9%EB%9F%89+%EC%A7%81%EB%A5%98%EB%B2%84%EC%8A%A4+%EC%BB%A4%ED%8C%A8%EC%8B%9C%ED%84%B0%EC%9D%98+%EA%B3%A0%EC%9E%A5%EC%A7%84%EB%8B%A8%EC%9D%84+%EC%9C%84%ED%95%9C+%EC%99%B8%EB%9E%80%ED%8A%B9%EC%84%B1+%EB%B0%98%EC%98%81%EC%9D%98+%EB%A0%88%ED%8D%BC%EB%9F%B0%EC%8A%A4+%EB%AA%A8%EB%8D%B8+%EA%B0%9C%EC%84%A0&rft.jtitle=%EC%A0%84%EA%B8%B0%ED%95%99%ED%9A%8C%EB%85%BC%EB%AC%B8%EC%A7%80+P&rft.au=%EC%9D%B4%ED%83%9C%EB%B4%89%28Tae-Bong+Lee%29&rft.date=2017&rft.pub=%EB%8C%80%ED%95%9C%EC%A0%84%EA%B8%B0%ED%95%99%ED%9A%8C&rft.issn=1229-800X&rft.eissn=2586-7792&rft.volume=66P&rft.issue=4&rft.spage=213&rft.epage=218&rft.externalDocID=NODE07274398 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1229-800X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1229-800X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1229-800X&client=summon |