수술실에서 방사선 차폐기 사용 유무에 따른 공간산란선량분포의 측정

This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by $30^{\circ}$ in the interval of the radius...

Full description

Saved in:
Bibliographic Details
Published in방사선기술과학 Vol. 40; no. 4; pp. 549 - 556
Main Authors 도상록(Do Sang-Lock), 조평곤(Cho Pyong-Kon), 김성진(Kim Seong-Jin), 정동경(Jung Dong Kyung)
Format Journal Article
LanguageKorean
Published 대한방사선과학회(구 대한방사선기술학회) 31.12.2017
KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY
대한방사선과학회
Subjects
Online AccessGet full text

Cover

Loading…
Abstract This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by $30^{\circ}$ in the interval of the radius 50 cm on the height of 95 cm based on the head of the patient, and it was measured by increasing $30^{\circ}$ with the interval of 50 cm in the vertical side of each horizontal side. In the same method, the radiation shielding was installed and measured. The result of measurement shows that the horizontal side of 50 cm distance was $0^{\circ}$, $90^{\circ}$ and $180^{\circ}$, was $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, and $2.69{\pm}0.15mSv/h$ in the $270^{\circ}$ direction, and was $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, and $1.37{\pm}0.11mSv/h$ after the use of the radiation shielding. In addition, the vertical distribution in horizontal direction $90^{\circ}$ with 50 cm distance was $30^{\circ}$, $60^{\circ}$, $120^{\circ}$, was $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, and $5.40{\pm}0.22mSv/h$ in $150^{\circ}$, and was $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, and $1.92{\pm}0.13mSv/h\;mR/h$ after the use of the radiation shielding. Both direction showed decrease according to the use of the radiation shielding. Therefore, radiation related workers who work in operating rooms should recognize the spatial scattered dose distribution exactly and need to try to prevent the risk of radiation exposure with proper protective measures. 본 연구는 C-arm의 공간산란선량분포를 파악해 보고자, 최근에 개발된 방사선 차폐기의 사용 유무에 따른 공간산란선량분포를 비교하였다. 수평면 분포는 95 cm 높이에서 환자 머리를 기준으로 반경 50 cm 간격으로 $30^{\circ}$씩 증가하였고, 각 수평면의 수직면 내에서 반경 50 cm 간격으로 $30^{\circ}$씩 증가하며 측정하였다. 동일한 방법으로 방사선 차폐기를 설치 후 측정하였다. 측정결과 50 cm 거리 수평면은 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ 그리고 $270^{\circ}$ 방향에서 $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, 그리고 $2.69{\pm}0.15mSv/h$, 방사선 차폐기 사용 후 $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, 그리고 $1.37{\pm}0.11mSv/h$로 나타났다. 또한, 50 cm 거리 수평 방향 $90^{\circ}$의 수직 분포는 $30^{\circ}$, $60^{\circ}$, $120^{\circ}$ 그리고 $150^{\circ}$에서 $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, 그리고 $5.40{\pm}0.22mSv/h$, 방사선 차폐기 사용 후 각 각 $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, 그리고 $1.92{\pm}0.13mSv/h$이었다. 방사선 차폐기 사용에 따라 각 방향 모두에서 감소하였다. 따라서 수술실에 근무하는 방사선관계종사자는 공간산란선량 분포를 정확히 인지하고 적절한 방호 대책으로 피폭의 위해를 방지하는 노력이 필요하다고 사료된다.
AbstractList This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by $30^{\circ}$ in the interval of the radius 50 cm on the height of 95 cm based on the head of the patient, and it was measured by increasing $30^{\circ}$ with the interval of 50 cm in the vertical side of each horizontal side. In the same method, the radiation shielding was installed and measured. The result of measurement shows that the horizontal side of 50 cm distance was $0^{\circ}$, $90^{\circ}$ and $180^{\circ}$, was $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, and $2.69{\pm}0.15mSv/h$ in the $270^{\circ}$ direction, and was $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, and $1.37{\pm}0.11mSv/h$ after the use of the radiation shielding. In addition, the vertical distribution in horizontal direction $90^{\circ}$ with 50 cm distance was $30^{\circ}$, $60^{\circ}$, $120^{\circ}$, was $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, and $5.40{\pm}0.22mSv/h$ in $150^{\circ}$, and was $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, and $1.92{\pm}0.13mSv/h\;mR/h$ after the use of the radiation shielding. Both direction showed decrease according to the use of the radiation shielding. Therefore, radiation related workers who work in operating rooms should recognize the spatial scattered dose distribution exactly and need to try to prevent the risk of radiation exposure with proper protective measures. 본 연구는 C-arm의 공간산란선량분포를 파악해 보고자, 최근에 개발된 방사선 차폐기의 사용 유무에 따른 공간산란선량분포를 비교하였다. 수평면 분포는 95 cm 높이에서 환자 머리를 기준으로 반경 50 cm 간격으로 $30^{\circ}$씩 증가하였고, 각 수평면의 수직면 내에서 반경 50 cm 간격으로 $30^{\circ}$씩 증가하며 측정하였다. 동일한 방법으로 방사선 차폐기를 설치 후 측정하였다. 측정결과 50 cm 거리 수평면은 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ 그리고 $270^{\circ}$ 방향에서 $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, 그리고 $2.69{\pm}0.15mSv/h$, 방사선 차폐기 사용 후 $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, 그리고 $1.37{\pm}0.11mSv/h$로 나타났다. 또한, 50 cm 거리 수평 방향 $90^{\circ}$의 수직 분포는 $30^{\circ}$, $60^{\circ}$, $120^{\circ}$ 그리고 $150^{\circ}$에서 $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, 그리고 $5.40{\pm}0.22mSv/h$, 방사선 차폐기 사용 후 각 각 $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, 그리고 $1.92{\pm}0.13mSv/h$이었다. 방사선 차폐기 사용에 따라 각 방향 모두에서 감소하였다. 따라서 수술실에 근무하는 방사선관계종사자는 공간산란선량 분포를 정확히 인지하고 적절한 방호 대책으로 피폭의 위해를 방지하는 노력이 필요하다고 사료된다.
본 연구는 C-arm의 공간산란선량분포를 파악해 보고자, 최근에 개발된 방사선 차폐기의 사용 유무에 따른 공간산란선량분포를 비교하였다. 수평면 분포는 95 cm 높이에서 환자 머리를 기준으로 반경 50 cm 간격으로 30°씩 증가하였고, 각 수평면의 수직면 내에서 반경 50 cm 간격으로 30°씩 증가하며 측정하였다. 동일한 방법으로 방사선 차폐기를 설치 후 측정하였다. 측정결과 50 cm 거리 수평면은 0°, 90°, 180° 그리고 270° 방향에서 1.77±0.12, 1.90±0.13, 2.12±0.14, 그리고2.69±0.15mSv/h, 방사선 차폐기 사용 후 1.59±0.12, 0.99±0.09, 1.47±0.11, 그리고 1.37±0.11mSv/h로 나타났다. 또한, 50 cm 거리 수평 방향 90°의 수직 분포는 30°, 60°, 120° 그리고 150°에서 3.85±0.18, 9.15±0.28, 10.82±0.31, 그리고 5.40±0.22mSv/h, 방사선 차폐기 사용 후 각 각 2.03±0.13, 4.32±0.19, 2.76±0.16, 그리고 1.92±0.13mSv/h이었다. 방사선 차폐기 사용에 따라 각 방향 모두에서 감소하였다. 따라서 수술실에 근무하는 방사선관계종사자는 공간산란선량 분포를 정확히 인지하고 적절한 방호 대책으로 피폭의 위해를 방지하는 노력이 필요하다고 사료된다 This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to understand the spatial scattered dose distribution of C-arm. The horizontal side distribution increased by 30° in the interval of the radius 50 cm on the height of 95 cm based on the head of the patient, and it was measured by increasing 30° with the interval of 50 cm in the vertical side of each horizontal side. In the same method, the radiation shielding was installed and measured. The result of measurement shows that the horizontal side of 50 cm distance was 0°, 90° and 180°, was 1.77±0.12, 1.90±0.13, 2.12±0.14, and 2.69±0.15 mSv/h in the 270° direction, and was 1.59±0.12, 0.99±0.09, 1.47±0.11, and 1.37±0.11 mSv/h after the use of the radiation shielding. In addition, the vertical distribution in horizontal direction 90° with 50 cm distance was 30°, 60°, 120°, was 3.85±0.18, 9.15±0.28, 10.82±0.31, and 5.40±0.22 mSv/h in 150°, and was 2.03±0.13, 4.32±0.19, 2.76±0.16, and 1.92±0.13 mSv/h mR/h after the use of the radiation shielding. Both direction showed decrease according to the use of the radiation shielding. Therefore, radiation related workers who work in operating rooms should recognize the spatial scattered dose distribution exactly and need to try to prevent the risk of radiation exposure with proper protective measures. KCI Citation Count: 3
Author 김성진(Kim Seong-Jin)
정동경(Jung Dong Kyung)
도상록(Do Sang-Lock)
조평곤(Cho Pyong-Kon)
Author_xml – sequence: 1
  fullname: 도상록(Do Sang-Lock)
– sequence: 2
  fullname: 조평곤(Cho Pyong-Kon)
– sequence: 3
  fullname: 김성진(Kim Seong-Jin)
– sequence: 4
  fullname: 정동경(Jung Dong Kyung)
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002298560$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNpNkDlLA1EUhR8SwS1_wGoaC4sZ77x9yhBcEgVBU_uYLTKMzEDGxk5CioiFFooiLhEUDKQYcCG_KfP8D45LYXUOl--cC2cOVZI0CRFatMGyhUP5SnNnt2VhsIVFwaIWkCk0i4mkpm1zWSk9ltIkDJwZVM2yyAPCsZAcs1m0p_vXuj_Qp0_66lz3bo0iH-ruSPcGhs5fPs_OJ-Pc-D7cDA19OyhGbyVnFBd58Tw2Jq_vk7ynu3lxf1wmioeT4qP3eTbSd9eGHj_qweUCmm67B1lY_dN51FpbbdU3zK3t9Ua9tmXGDqWmYMzF7ZCQAAJuMwfalHHpUeZwF9uSSgw-80EK33Xc0PdF4AQUPIEJoVR4DplHy7-1SaetYj9SqRv96H6q4o6q7bQaCpcDSUxLdumXjaPsMFJJkB2oZm1z-3s_EJSXrxlI-McdpV6qvDSN_TA5DDuKgg2AeQlxAeQLOx6M6Q
ContentType Journal Article
Copyright COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED
Copyright_xml – notice: COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED
DBID P5Y
SSSTE
JDI
ACYCR
DEWEY 616.0757
DOI 10.17946/JRST.2017.40.4.03
DatabaseName 교보스콜라(Kyobo Scholar)
Scholar(스콜라)
KoreaScience
Korean Citation Index
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Medicine
DocumentTitleAlternate Measurement of Spatial Scattered Dose Distribution According to Presence or Absence of Radiation Shielding in the Operating Room
EISSN 2384-1168
EndPage 556
ExternalDocumentID oai_kci_go_kr_ARTI_2201824
JAKO201707464565080
4010026080670
GroupedDBID ALMA_UNASSIGNED_HOLDINGS
P5Y
SSSTE
.UV
JDI
ACYCR
ID FETCH-LOGICAL-k944-755a2fe33d0d61590f4568b4596a2184820c5c087ca9aecc7d9d40b7233447b93
ISSN 2288-3509
IngestDate Sun Aug 18 03:10:33 EDT 2024
Fri Dec 22 12:04:10 EST 2023
Tue Sep 17 19:35:49 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Issue 4
Keywords C-arm
radiation shielding
공간산란선량
방사선관계종사자
radiation related worker
방사선피폭 영향
spatial scattered dose distribution
방사선차폐기
risk of radiation exposure
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k944-755a2fe33d0d61590f4568b4596a2184820c5c087ca9aecc7d9d40b7233447b93
Notes KISTI1.1003/JNL.JAKO201707464565080
http://journal.iksrs.or.kr
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201707464565080&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
PageCount 8
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_2201824
kisti_ndsl_JAKO201707464565080
kyobo_bookcenter_4010026080670
PublicationCentury 2000
PublicationDate 2017-12-31
PublicationDateYYYYMMDD 2017-12-31
PublicationDate_xml – month: 12
  year: 2017
  text: 2017-12-31
  day: 31
PublicationDecade 2010
PublicationTitle 방사선기술과학
PublicationTitleAlternate Journal of radiological science and technology
PublicationYear 2017
Publisher 대한방사선과학회(구 대한방사선기술학회)
KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY
대한방사선과학회
Publisher_xml – name: 대한방사선과학회(구 대한방사선기술학회)
– name: KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY
– name: 대한방사선과학회
SSID ssib036278625
ssib053376989
ssib030194475
ssib023718648
Score 1.6758349
Snippet This study compared the spatial scattered dose distribution according to whether the recently developed radiation shielding is used or not in order to...
본 연구는 C-arm의 공간산란선량분포를 파악해 보고자, 최근에 개발된 방사선 차폐기의 사용 유무에 따른 공간산란선량분포를 비교하였다. 수평면 분포는 95 cm 높이에서 환자 머리를 기준으로 반경 50 cm 간격으로 30°씩 증가하였고, 각 수평면의 수직면 내에서 반경 50 cm...
SourceID nrf
kisti
kyobo
SourceType Open Website
Open Access Repository
Publisher
StartPage 549
SubjectTerms 방사선과학
TableOfContents 서 론 Ⅱ. 대상 및 방법 Ⅲ. 결 과 Ⅳ. 고 찰 Ⅴ. 결 론 REFERENCES
Title 수술실에서 방사선 차폐기 사용 유무에 따른 공간산란선량분포의 측정
URI https://scholar.kyobobook.co.kr/article/detail/4010026080670
http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201707464565080&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002298560
Volume 40
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 방사선기술과학, 2017, 40(4), , pp.549-556
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnR1Na9RANLT14kUUFetHCeKclqzZZCaZOSbpllpRQVfoydB8SVnZhbU96EGk7KHioT0oFqm6goKFHhb8oD_F39Ck_8H3JtnNrvWjesm-vHl58z52Mu-FmXmKcsVIrMiCsEMLanGiUW6FmghsU6ORxRJrCVKOJbnK96Y1f5cuLLLFicnvI6uWVleCavj4l_tK_sergAO_4i7Zf_DskCkgAAb_whU8DNcj-ZjUPcI5EbwAHF0CLnEoAsImIsdQIrwKqbvE1YkjJMogjle0OXoFIWwDTrOEz8nnHOJyQFbGyIUDDCRKeLI_Fxvcsj_ZjaDIDdsYMKlIXiZxmQR07DPnmROJOq63GMgiMXOECymvJYmlTIUAs6BvLi8oXEMAnslLaA6i7D9oOlRrxGS5cB52IxgRAv92VIfQm458J0GeIEQhugkRuNSvBgKVJB4ikLcUGFWQvB1akgBClOq6uQI24XSMC2pU9ChyLmCs2dFPNDDtFwdBFoNKknuSda6H9zczjCuNgAMcyqnBMGAkmEzPbRDnOJNTrVbLixQV0xGjYiSyYfkR7ocmTawxgAXBb99p4FpHu0r1Kq3qZhkiDJZF_BQ5jJ1R3gyX_fttv9nxIRO75hvAiRt0Ujlm2ILhYtsbT-qDN71hQkhklYk4zDICT54c3luGDan28B5yEhsrnWKlyIHqxQ44FP7qIdEh1cT8axl_H7WDNkSOrU4yEjk2TionipRPdfLxe0qZaLZPK_ey9a1svZc9_5C92sy622ra38nWdrNuT836nw42Nvf3-ioiXu-o2XYv3f0CdGr6op9-3FP3P3_d73eztX769ik8kb57ln7rHmzsZm-21GzvfdZ7eUZpzNUb3rxW1DrRmqC5ZjO2ZCSxaUZ6BDmG0BNIbHhAmcD3JacQp4cs1Lkd4mn6YWhHIqJ6YBsmntgZCPOsMtVqt-Jzigo5UxwLZoQiCWkobE5pQq0A4vDYjKCHaWVGmsZvRQ8f-AvO9VtoOCw7hMkdJJBIgDbzMc3HJeJxx6d6TZ4-yHFb37RyGYwpHf57x58_CtEF5Xg5Xi4qUyud1fgSBPkrwYz8v_wATBPJHQ
link.rule.ids 230,315,786,790,891,27955,27956
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EC%88%98%EC%88%A0%EC%8B%A4%EC%97%90%EC%84%9C+%EB%B0%A9%EC%82%AC%EC%84%A0+%EC%B0%A8%ED%8F%90%EA%B8%B0+%EC%82%AC%EC%9A%A9+%EC%9C%A0%EB%AC%B4%EC%97%90+%EB%94%B0%EB%A5%B8+%EA%B3%B5%EA%B0%84%EC%82%B0%EB%9E%80%EC%84%A0%EB%9F%89%EB%B6%84%ED%8F%AC%EC%9D%98+%EC%B8%A1%EC%A0%95&rft.jtitle=%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B8%B0%EC%88%A0%EA%B3%BC%ED%95%99%2C+40%284%29&rft.au=%EB%8F%84%EC%83%81%EB%A1%9D&rft.au=%EC%A1%B0%ED%8F%89%EA%B3%A4&rft.au=%EA%B9%80%EC%84%B1%EC%A7%84&rft.au=%EC%A0%95%EB%8F%99%EA%B2%BD&rft.date=2017-12-31&rft.pub=%EB%8C%80%ED%95%9C%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B3%BC%ED%95%99%ED%9A%8C&rft.issn=2288-3509&rft.eissn=2384-1168&rft.spage=549&rft.epage=556&rft_id=info:doi/10.17946%2FJRST.2017.40.4.03&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_2201824
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2288-3509&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2288-3509&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2288-3509&client=summon