고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지

For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second e...

Full description

Saved in:
Bibliographic Details
Published in전기학회 논문지 P권, 53(3) Vol. 53P; no. 3; pp. 148 - 151
Main Authors 韓泰煥(Tae-Hwan Han), 禹天熙(Chun-Hee Woo)
Format Journal Article
LanguageKorean
Published 대한전기학회 2004
Subjects
Online AccessGet full text
ISSN1229-800X
2586-7792

Cover

Loading…
Abstract For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.
AbstractList For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp. KCI Citation Count: 0
For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as electric discharge lamp, Electric field is producted in electric discharge tube, So accelerative electron collide against vapor atom and second electron is generated, And rapidly the current flow to electric discharge tube. This starting voltage is high voltage and source for melting contact that relay is according as turn on/off high pressure sodium vapor lamp. Consequently, This paper propose that the prevention of melting contact in accordance relay of controller for turn on/off high pressure sodium vapor lamp.
Author 禹天熙(Chun-Hee Woo)
韓泰煥(Tae-Hwan Han)
Author_xml – sequence: 1
  fullname: 韓泰煥(Tae-Hwan Han)
– sequence: 2
  fullname: 禹天熙(Chun-Hee Woo)
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART000943698$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNpFjLFLw0AYxQ-pYK39H7IILoG7L7lcbiy1arVYkA5uR5ImElpTSXRwEyki4qBopUMqXdR2q7RCB_-i5vo_GFvB6b33fb_31lEmaAXuCsoCNQ2VMQ4ZlCUAXDUxPl5D-SjybazrzNAASBY5s3FfdjpKct2d302Tt0HyOpg_t2Wvq8j-Q_L0ORt_K_LmPnWy11Zk3J534vQVy5fJbDr65ZL3SdK_lb1Jen5MS4tu_CVHQyUZDeXH1QZa9axm5Ob_NIdqO6VacU-tVHfLxUJFbXCNqQR0xwSPWQ4jOvZsTwfLdImJuUcc6lCicQ0MSAOzKecehTrzgFg2ZxTb3NJyaGs5G4SeaDi-aFn-Qk9aohGKwlGtLAhlJoEU3VyiDT8690VQj5piv3BQBYx14GDojBPN5P9ccBH6p27dt8RZaqzwUhxWt0uYAMUGZtoPfteK9A
ContentType Journal Article
DBID DBRKI
TDB
JDI
ACYCR
DEWEY 620
621.3
620.11297
DatabaseName DBPIA - 디비피아
Nurimedia DBPIA Journals
KoreaScience
Korean Citation Index
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Engineering
DocumentTitleAlternate The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp
DocumentTitle_FL The Prevention of Melting Contact in Accordance Relay of Controller for Turn on/off High Pressure Sodium Vapor Lamp
EISSN 2586-7792
EndPage 151
ExternalDocumentID oai_kci_go_kr_ARTI_157812
JAKO200429264791389
NODE01250607
GroupedDBID .UV
ALMA_UNASSIGNED_HOLDINGS
DBRKI
TDB
JDI
ACYCR
ID FETCH-LOGICAL-k937-124c82f7ac7140fbf42a8e1809f1c5c51393262f1c7b599f52d7f21ab9750b9a3
ISSN 1229-800X
IngestDate Sun Mar 09 07:51:27 EDT 2025
Fri Dec 22 12:04:04 EST 2023
Thu Feb 06 13:25:42 EST 2025
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 3
Keywords controller
High pressure sodium vapor lamp
Starting voltage
melting contactor
Electric discharge lamp
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k937-124c82f7ac7140fbf42a8e1809f1c5c51393262f1c7b599f52d7f21ab9750b9a3
Notes KISTI1.1003/JNL.JAKO200429264791389
G704-001568.2004.53.3.004
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO200429264791389&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
PageCount 4
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_157812
kisti_ndsl_JAKO200429264791389
nurimedia_primary_NODE01250607
PublicationCentury 2000
PublicationDate 2004
PublicationDateYYYYMMDD 2004-01-01
PublicationDate_xml – year: 2004
  text: 2004
PublicationDecade 2000
PublicationTitle 전기학회 논문지 P권, 53(3)
PublicationTitleAlternate 전기학회논문지. The Transactions of the Korean Institute of Electrical Engineers. P
PublicationYear 2004
Publisher 대한전기학회
Publisher_xml – name: 대한전기학회
SSID ssib044763221
ssib005299917
ssib013785837
ssib053377038
ssib006781898
ssib036278838
ssib022234313
Score 1.5313053
Snippet For turn on high pressure sodium vapor lamp, Starting Voltage is very important factor. This starting voltage supply to high pressure sodium vapor lamp as...
SourceID nrf
kisti
nurimedia
SourceType Open Website
Open Access Repository
Publisher
StartPage 148
SubjectTerms 전기공학
Title 고압 나트륨램프의 점등과 소등을 위한 제어기의 릴레이 접점의 융착 방지
URI https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01250607
http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO200429264791389&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART000943698
Volume 53P
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 전기학회 논문지 P권, 2004, 53(3), , pp.148-151
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3Pa9RAFA61F72IomL9USI4p7Kymc1sZo5JNlIrbT1U6C1sshuRla3U9uJBRIqIeFC00sNWelHbW6UVevAvatL_wW9esptUFKuwhLfzZl7ezOzM-97szBvDuNmMMWZg52pJo8PhoEhVk13erDltvY1NwiDQlSyzc83p-_bMolgcOxVXdi2trkS34qe_PVfyP72KNPSrPiX7Dz07EooE0OhfPNHDeJ6oj1ngMq_B3DoLfKYEPlMs8JjkTEkWtJgEW-oUVzCXCBUQ0WIKGNKmYqDllKZcveeBMjWYZxWyPZ94ssmkX-FROWkTT_kkqkUa-CNRPvGazLNJlGRevfo-KJXzPJ1byoLn2SMBVkWpqp6Q7AlNQKCrSBRRlN1h-ZVNQ8BdyJBVJXJNFREu6pU3mkBdSRufGq2QNXWPClL18WvUt3fI6uL0qN7U3o2CgHAlyyy-fk9efY8Ps7RYEfZyuOZSrraSPr7ehFJK_3s1KvaFcwyGen0xN7-UxoXE2HDyKwELO2Ll4UcLSGIVMXmPRQv_xYofixfeix-GD5bC3nIIr-hOaGFappu4gUb1zD_7LCjnYK5dhMpZY2SVpQtuNRwpZAlhNZwE5hzN6cA_jqz8827bMFi8hITwJhwYFTqROqw7_EDtHD0EnOsvAwWe7q_qqywwH1ag3cI542zhk5luPsDOG2O9pQtGfLi3la2vm-mLjaPXB-nn7fTT9tGHtWxzw8y23qbvvx3u_TCzl29AZZtrZjZYO1ofgDXIPu4fHuzqfOmX_XTrVba5j-R3KERlB9-z3R0z3d3Jvj6_aCzcDhb86VpxI0mtBxhfAxaOJU-cdqzDXCZRYvO27OoIeIkVi1jAm4I3xPHFiYRSieAdJ-FWO1LA5ZFqNy4Z4_2lfveyYbZ57Mhu0gRi79pxxOHWi8hJ7EgIEXV4fcKYpDYK-50nj8IZ9-48J-wI_8VRenPBhHEDjUc9_cceh5BR04aP8-g14dx8KwAq1YFFnSsnEHLVOJPvVtPLjteM8ZXl1e51APGVaJJ-ST8BSL61bQ
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EA%B3%A0%EC%95%95+%EB%82%98%ED%8A%B8%EB%A5%A8%EB%9E%A8%ED%94%84%EC%9D%98+%EC%A0%90%EB%93%B1%EA%B3%BC+%EC%86%8C%EB%93%B1%EC%9D%84+%EC%9C%84%ED%95%9C+%EC%A0%9C%EC%96%B4%EA%B8%B0%EC%9D%98+%EB%A6%B4%EB%A0%88%EC%9D%B4+%EC%A0%91%EC%A0%90%EC%9D%98+%EC%9C%B5%EC%B0%A9+%EB%B0%A9%EC%A7%80&rft.jtitle=%EC%A0%84%EA%B8%B0%ED%95%99%ED%9A%8C+%EB%85%BC%EB%AC%B8%EC%A7%80+P%EA%B6%8C%2C+53%283%29&rft.au=%ED%95%9C%ED%83%9C%ED%99%98&rft.au=%EC%9A%B0%EC%B2%9C%ED%9D%AC&rft.date=2004&rft.pub=%EB%8C%80%ED%95%9C%EC%A0%84%EA%B8%B0%ED%95%99%ED%9A%8C&rft.issn=1229-800X&rft.eissn=2586-7792&rft.spage=148&rft.epage=151&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_157812
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1229-800X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1229-800X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1229-800X&client=summon