진단용 방사선발생장치 이용에 적용되는 법제의 비교

Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subjec...

Full description

Saved in:
Bibliographic Details
Published in방사선기술과학 Vol. 38; no. 3; pp. 277 - 286
Main Authors 고종경(Jong-Kyung Ko), 전여령(Yeo-Ryeong Jeon), 한은옥(Eun-Ok Han), 조평곤(Pyong -Kon Cho), 김용민(Yong-Min Kim)
Format Journal Article
LanguageKorean
Published 대한방사선과학회(구 대한방사선기술학회) 30.09.2015
KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY
대한방사선과학회
Subjects
Online AccessGet full text
ISSN2288-3509
2384-1168
DOI10.17946/JRST.2015.38.3.12

Cover

Abstract Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary. 국내에 사용되고 있는 진단용 방사선발생장치는 78,000여대에 이르고 있다. 인체 대상의 진단 목적으로 사용할 때에는 의료법의 적용을 받고, 동물 대상의 진단 목적으로 사용할 때는 수의사법의 적용을 받는다. 그 이외의 목적으로 사용 시에는 원자력안전법의 적용을 받는다. 동일한 방사선발생장치라도 사용목적 및 대상에 따라 적용되는 법제가 달라지며, 다원화된 규정이 적용되는 문제점인 법제의 혼란을 방지하기 위해 법제 내용의 분석 및 비교가 필요하다. 본 연구는 질적 조사로, 원자력안전 법, 의료법, 수의사법과 그 하위 규정에 적용되는 진단용 방사선발생장치 도입에 대한 행정절차, 안전성 검사, 인력 관리, 구역 관리, 행정처분에 관한 내용이다. 원자력안전법 하위규정에서는 진단용 방사선발생장치 도입은 허가개념으로 행정절차가 복잡하고 구비요건이 많다. 사용에 따른 안전성 검사는 방사선안전관리 전 분야에 걸쳐 감사 성격의 정기검사를 받게 된다. 안전관리자 및 종사자에 대해 해마다 법정 정기 교육을 받아야 한다. 방사선관리구역을 지정하는 방사선량률 기준이 다르며 방사선량률 측정 의무가 있다. 법제 위반 시 부과되는 행정처분의 양적 차이가 최대 10배에 이르며 전 분야에 걸쳐 원자력안전법 하위규정 적용 시 방사선안전관리 부담이 가장 크다. 동일한 진단용 방사선발생장치의 사용 목적과 촬영대상에 따라 다르게 적용되고 있는 현행 법 제도 하에서는 사용주체에 따라 방사선 안전관리를 위한 법제 내용의 형평성이 결여되어 있고, 혼란의 우려가 있으므로 진단용 방사선발생장치 이용에 따른 법제의 일원화 또는 표준화 등의 대안이 필요할 것으로 예상된다.
AbstractList Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary. 국내에 사용되고 있는 진단용 방사선발생장치는 78,000여대에 이르고 있다. 인체 대상의 진단 목적으로 사용할 때에는 의료법의 적용을 받고, 동물 대상의 진단 목적으로 사용할 때는 수의사법의 적용을 받는다. 그 이외의 목적으로 사용 시에는 원자력안전법의 적용을 받는다. 동일한 방사선발생장치라도 사용목적 및 대상에 따라 적용되는 법제가 달라지며, 다원화된 규정이 적용되는 문제점인 법제의 혼란을 방지하기 위해 법제 내용의 분석 및 비교가 필요하다. 본 연구는 질적 조사로, 원자력안전 법, 의료법, 수의사법과 그 하위 규정에 적용되는 진단용 방사선발생장치 도입에 대한 행정절차, 안전성 검사, 인력 관리, 구역 관리, 행정처분에 관한 내용이다. 원자력안전법 하위규정에서는 진단용 방사선발생장치 도입은 허가개념으로 행정절차가 복잡하고 구비요건이 많다. 사용에 따른 안전성 검사는 방사선안전관리 전 분야에 걸쳐 감사 성격의 정기검사를 받게 된다. 안전관리자 및 종사자에 대해 해마다 법정 정기 교육을 받아야 한다. 방사선관리구역을 지정하는 방사선량률 기준이 다르며 방사선량률 측정 의무가 있다. 법제 위반 시 부과되는 행정처분의 양적 차이가 최대 10배에 이르며 전 분야에 걸쳐 원자력안전법 하위규정 적용 시 방사선안전관리 부담이 가장 크다. 동일한 진단용 방사선발생장치의 사용 목적과 촬영대상에 따라 다르게 적용되고 있는 현행 법 제도 하에서는 사용주체에 따라 방사선 안전관리를 위한 법제 내용의 형평성이 결여되어 있고, 혼란의 우려가 있으므로 진단용 방사선발생장치 이용에 따른 법제의 일원화 또는 표준화 등의 대안이 필요할 것으로 예상된다.
국내에 사용되고 있는 진단용 방사선발생장치는 78,000여대에 이르고 있다. 인체 대상의 진단 목적으로 사용할 때에는 의료법의 적용을 받고, 동물 대상의 진단 목적으로 사용할 때는 수의사법의 적용을 받는다. 그 이외의 목적으로 사용 시에는 원자력안전법의 적용을 받는다. 동일한 방사선발생장치라도 사용목적 및 대상에 따라 적용되는 법제가 달라지며, 다원화된 규정이 적용되는 문제점인 법제의 혼란을 방지하기 위해 법제 내용의 분석 및 비교가 필요하다. 본 연구는 질적 조사로, 원자력안전법, 의료법, 수의사법과 그 하위 규정에 적용되는 진단용 방사선발생장치 도입에 대한 행정절차, 안전성 검사, 인력 관리, 구역 관리, 행정처분에 관한 내용이다.원자력안전법 하위규정에서는 진단용 방사선발생장치 도입은 허가개념으로 행정절차가 복잡하고 구비요건이 많다. 사용에 따른 안전성 검사는 방사선안전관리 전 분야에 걸쳐 감사 성격의 정기검사를 받게 된다. 안전관리자 및 종사자에 대해 해마다 법정 정기 교육을 받아야 한다. 방사선관리구역을 지정하는 방사선량률 기준이 다르며 방사선량률 측정 의무가 있다. 법제 위반 시 부과되는 행정처분의 양적 차이가 최대 10배에 이르며 전 분야에 걸쳐 원자력안전법 하위규정 적용 시 방사선안전관리 부담이 가장 크다. 동일한 진단용 방사선발생장치의 사용 목적과 촬영대상에 따라 다르게 적용되고 있는 현행 법 제도 하에서는 사용주체에 따라 방사선 안전관리를 위한 법제 내용의 형평성이 결여되어 있고, 혼란의 우려가 있으므로 진단용 방사선발생장치 이용에 따른 법제의 일원화 또는 표준화 등의 대안이 필요할 것으로 예상된다. Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for hu-man subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been provisions are necessary compared to the analysis of legal content in order to prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing character-istics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radia-tion dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions.And it is applied differently depending on the purpose and the imaging target using the same diag-nostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is ex-pected to be necessary. KCI Citation Count: 4
Author 한은옥(Eun-Ok Han)
전여령(Yeo-Ryeong Jeon)
김용민(Yong-Min Kim)
조평곤(Pyong -Kon Cho)
고종경(Jong-Kyung Ko)
Author_xml – sequence: 1
  fullname: 고종경(Jong-Kyung Ko)
– sequence: 2
  fullname: 전여령(Yeo-Ryeong Jeon)
– sequence: 3
  fullname: 한은옥(Eun-Ok Han)
– sequence: 4
  fullname: 조평곤(Pyong -Kon Cho)
– sequence: 5
  fullname: 김용민(Yong-Min Kim)
BackLink https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002033996$$DAccess content in National Research Foundation of Korea (NRF)
BookMark eNpVkL1Kw1AAhS-iYK19Aacsgkvi_c-9YylaWwuFmv2SXwkpCTRdHNVOunRQLNJKF9GCQxEd-krmPoTRujidA-fjDN8O2EyzNARgD0EL2ZLyw3bvzLEwRMwiwiIWwhuggomgJkJcbJYdC2ESBuU2qOV57EHCsS04ZhXQ1C-j4vZVPy6MYrnQV296NC-WU30900_PejUx9OyjHPXD2NDzy7IV40lxc2cU7_d6PtWziVGsRl-f412wFbn9PKz9ZRU4x0dO48TsdJutRr1jJpJgUwjGImkHlCDGXUphxAIoQiKpi6gL_dDzXSaYjSRGnNiRz32GXE5CAgMRUpdUwcH6Nh1EKvFjlbnxb55nKhmoes9pKWxzInGJ7q_RJM6HsUqDvK_a9dPujydSGoCSSfiPu8i8THlZlvhhOgwHikIEIaY2pJBS8g3uXX19
ContentType Journal Article
Copyright COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED
Copyright_xml – notice: COPYRIGHT(C) KYOBO BOOK CENTRE ALL RIGHTS RESERVED
DBID P5Y
SSSTE
JDI
ACYCR
DEWEY 616.0757
DOI 10.17946/JRST.2015.38.3.12
DatabaseName Kyobo Scholar Journals
Scholar(스콜라)
KoreaScience
Korean Citation Index
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Medicine
DocumentTitleAlternate Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices
EISSN 2384-1168
EndPage 286
ExternalDocumentID oai_kci_go_kr_ARTI_276392
JAKO201530360959092
4010024704044
GroupedDBID ALMA_UNASSIGNED_HOLDINGS
P5Y
SSSTE
.UV
JDI
ACYCR
ID FETCH-LOGICAL-k932-8855f97d43156a440f5d08e394a14a0cebca58571921637fc6c51a63e30d8e4a3
ISSN 2288-3509
IngestDate Sun Aug 18 03:10:33 EDT 2024
Fri Dec 22 11:58:31 EST 2023
Tue Feb 18 15:20:03 EST 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly false
Issue 3
Keywords 의료법
Nuclear Safety Act
Medical Service Act
원자력안전법
Radiation devices
Veterinarians Act
수의사법
진단용 방사선발생장치
Language Korean
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-k932-8855f97d43156a440f5d08e394a14a0cebca58571921637fc6c51a63e30d8e4a3
Notes KISTI1.1003/JNL.JAKO201530360959092
G704-001962.2015.38.3.013
OpenAccessLink http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201530360959092&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
PageCount 10
ParticipantIDs nrf_kci_oai_kci_go_kr_ARTI_276392
kisti_ndsl_JAKO201530360959092
kyobo_bookcenter_4010024704044
PublicationCentury 2000
PublicationDate 2015-09-30
PublicationDateYYYYMMDD 2015-09-30
PublicationDate_xml – month: 09
  year: 2015
  text: 2015-09-30
  day: 30
PublicationDecade 2010
PublicationTitle 방사선기술과학
PublicationTitleAlternate Journal of radiological science and technology
PublicationYear 2015
Publisher 대한방사선과학회(구 대한방사선기술학회)
KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY
대한방사선과학회
Publisher_xml – name: 대한방사선과학회(구 대한방사선기술학회)
– name: KOREAN SOCIETY OF RADIOLOGICAL TECHNOLOGY
– name: 대한방사선과학회
SSID ssib036278625
ssib053376989
ssib030194475
ssib023718648
Score 1.5724088
Snippet Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to...
국내에 사용되고 있는 진단용 방사선발생장치는 78,000여대에 이르고 있다. 인체 대상의 진단 목적으로 사용할 때에는 의료법의 적용을 받고, 동물 대상의 진단 목적으로 사용할 때는 수의사법의 적용을 받는다. 그 이외의 목적으로 사용 시에는 원자력안전법의 적용을 받는다. 동일한...
SourceID nrf
kisti
kyobo
SourceType Open Website
Open Access Repository
Publisher
StartPage 277
SubjectTerms 방사선과학
TableOfContents 서 론 Ⅱ. 대상 및 방법 Ⅲ. 결 과 Ⅳ. 고 찰 Ⅴ. 결 론
Title 진단용 방사선발생장치 이용에 적용되는 법제의 비교
URI https://scholar.kyobobook.co.kr/article/detail/4010024704044
http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201530360959092&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01
https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002033996
Volume 38
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX 방사선기술과학, 2015, 38(3), , pp.277-286
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnR27btRA0AqhoUEgQIRHZCS2Qj5s7669W67vLoQgQIJDSmfZPh-KDt1JR1JAgQSkguYKHieUoDQIIlFECIr8EvZHMLO270EgCjT2eHY8M7vj9c5Y4x3DuMrBawM_VVo8atsWA4_eEpSmlmDgPjs8iUWssy3ueMsP2MoqX5079m4qa2ljPa4lT__4X8n_WBVwYFf8S_YfLDtmCgiAwb5wBAvD8Ug2Js06UT4RjDQDIgKiBGKkIgpCfUAFNkCIEi5RdQ0wouyySRYYSmRD39YkiiMQSCLFNY1qkICNWWrAJ9LWbcBGOFNtATTAfVoTRSQrFHCJ5CV1IQ5YauYBikHFFQk4KWp5Vk7yoaoDvcBWxIgKQ0kANA0UJiU-Nbgdu5j-iFySKX2jcongGuOSoDEhKXrFyo6i2AAxwRSXQkbVFaHZQa8Vn-HiaA2hfYkIWYlm019YHF6lg5RzQg9cXXMcyzh8GGY7jYACDpM3u-vCg0y5XWifFjgqmOU4RY2hajUpK9wUjolb7Bl-YM3DEgFYz_ve_RamKvIaFTVaK5PTZzYY_23hn9livJushQ_7YXcQQiB1M3Rh3ZHg2hwHHXT6w-1nzeo97VJwaLxJGA1rhMR9I8fXnuvDTB9fQ0ThY51SrPNY9bz8fw11v35AcwgUMXpaw_OTftwHv6836Ez5fa1TxskyYDNVMftOG3Pd_hnjRv55M3v9Jf-wa2Z7u_mLr_nmTra3lb_czj9-yvdHZr79HRrz90Mz33kOUDYcZa_emNm3t_nOVr49MrP9zZ8_hmeN1lKzVV-2ypIkVhcCHUsIzjvSb4PXzb2IMbvD27ZIqWSRwyI7wcxCiL993GTQo34n8RLuRB5Nqd0WKYvoOWO-1--l5w0T4i4X6xHFEK8wJ_GiCGKNmKXgMrtO4sgFY1GPQdhrP34Urqhbd3GE0OHEL_e2dJEAByfEaBwzudNByGzcUZn5sDIztmBcgVHThv2rgS8cgeaicWIyKy4Z8-uDjfQyeOLr8aJ-LH4BEmGqjg
linkProvider ISSN International Centre
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=%EC%A7%84%EB%8B%A8%EC%9A%A9+%EB%B0%A9%EC%82%AC%EC%84%A0%EB%B0%9C%EC%83%9D%EC%9E%A5%EC%B9%98+%EC%9D%B4%EC%9A%A9%EC%97%90+%EC%A0%81%EC%9A%A9%EB%90%98%EB%8A%94+%EB%B2%95%EC%A0%9C%EC%9D%98+%EB%B9%84%EA%B5%90&rft.jtitle=%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B8%B0%EC%88%A0%EA%B3%BC%ED%95%99%2C+38%283%29&rft.au=%EA%B3%A0%EC%A2%85%EA%B2%BD&rft.au=%EC%A0%84%EC%97%AC%EB%A0%B9&rft.au=%ED%95%9C%EC%9D%80%EC%98%A5&rft.au=%EC%A1%B0%ED%8F%89%EA%B3%A4&rft.date=2015-09-30&rft.pub=%EB%8C%80%ED%95%9C%EB%B0%A9%EC%82%AC%EC%84%A0%EA%B3%BC%ED%95%99%ED%9A%8C&rft.issn=2288-3509&rft.eissn=2384-1168&rft.spage=277&rft.epage=286&rft_id=info:doi/10.17946%2FJRST.2015.38.3.12&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_276392
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2288-3509&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2288-3509&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2288-3509&client=summon