자동봉합기를 이용한 전폐절제술후 발생한 좌심방 파열

The usage of autosuture instruments and techniques in resection of bronchovascular structures gained increasing acceptance amongst surgeons in the recent years. The manipulation of these devices are simple, safe, and shortens operating time by avoiding numerous ties and sutures. We have been using a...

Full description

Saved in:
Bibliographic Details
Published inTaehan Hyungbu Oekwa Hakhoe chi Vol. 27; no. 5; pp. 418 - 421
Main Author 배기만
Format Journal Article
LanguageKorean
Published 1994
Subjects
Online AccessGet full text
ISSN0301-2859

Cover

Loading…
More Information
Summary:The usage of autosuture instruments and techniques in resection of bronchovascular structures gained increasing acceptance amongst surgeons in the recent years. The manipulation of these devices are simple, safe, and shortens operating time by avoiding numerous ties and sutures. We have been using autosuture instruments in most of pulmonary resections in Yongdong Severance hospital, and had a satisfactory results. However, we recently have experienced post-pneumonectomy rupture of left pulmonary vein on postoperative one day where the rupture site was in the border of left atrium and left pulmonary vein where the stapler was fired. The patient underwent emergency operation to control massive bleeding and successfully managed by left atrial suture.
Bibliography:KISTI1.1003/JNL.JAKO199411919806536
ISSN:0301-2859