MDCT에서 선량 변화에 따른 딥러닝 재구성 기법의 유용성 연구
This study aims to evaluate the usefulness of Deep Learning Image Reconstruction (TrueFidelity, TF), the image quality of existing Filtered Back Projection (FBP) and Adaptive Statistical Iterative Reconstruction-Veo (ASIR-V) were compared. Noise, CNR, and SSIM were measured by obtaining images with...
Saved in:
Published in | 한국방사선학회 논문지 Vol. 17; no. 1; pp. 37 - 46 |
---|---|
Main Authors | , , , , , , , , , , , |
Format | Journal Article |
Language | Korean |
Published |
한국방사선학회
28.02.2023
|
Subjects | |
Online Access | Get full text |
ISSN | 1976-0620 |
Cover
Loading…
Abstract | This study aims to evaluate the usefulness of Deep Learning Image Reconstruction (TrueFidelity, TF), the image quality of existing Filtered Back Projection (FBP) and Adaptive Statistical Iterative Reconstruction-Veo (ASIR-V) were compared. Noise, CNR, and SSIM were measured by obtaining images with doses fixed at 17.29 mGy and altered to 10.37 mGy, 12.10 mGy, 13.83 mGy, and 15.56 mGy in reconstruction techniques of FBP, ASIR-V 50%, and TF-H. TF-H has superior image quality compared to FBP and ASIR-V when the reconstruction technique change is given at 17.29 mGy. When dose changes were made, Noise, CNR, and SSIM were significantly different when comparing 10.37 mGy TF-H and FBP (p< 0.05), and no significant difference when comparing 10.37 mGy TF-H and ASIR-V 50% (p >0.05). TF-H has a dose-reduction effect of 30%, as the highest dose of 15.56 mGy ASIR-V has the same image quality as the lowest dose of 10.37 mGy TF-H. Thus, Deep Learning Reconstruction techniques (TF) were able to reduce dose compared to Iterative Reconstruction techniques (ASIR-V) and Filtered Back Projection (FBP). Therefore, it is considered to reduce the exposure dose of patients. |
---|---|
AbstractList | This study aims to evaluate the usefulness of Deep Learning Image Reconstruction (TrueFidelity, TF), the image quality of existing Filtered Back Projection (FBP) and Adaptive Statistical Iterative Reconstruction-Veo (ASIR-V) were compared. Noise, CNR, and SSIM were measured by obtaining images with doses fixed at 17.29 mGy and altered to 10.37 mGy, 12.10 mGy, 13.83 mGy, and 15.56 mGy in reconstruction techniques of FBP, ASIR-V 50%, and TF-H. TF-H has superior image quality compared to FBP and ASIR-V when the reconstruction technique change is given at 17.29 mGy. When dose changes were made, Noise, CNR, and SSIM were significantly different when comparing 10.37 mGy TF-H and FBP (p<0.05), and no significant difference when comparing 10.37 mGy TF-H and ASIR-V 50% (p>0.05). TF-H has a dose-reduction effect of 30%, as the highest dose of 15.56 mGy ASIR-V has the same image quality as the lowest dose of 10.37 mGy TF-H. Thus, Deep Learning Reconstruction techniques (TF) were able to reduce dose compared to Iterative Reconstruction techniques (ASIR-V) and Filtered Back Projection (FBP). Therefore, it is considered to reduce the exposure dose of patients. MDCT의 딥러닝 재구성 기법(TrueFidelity, TF)의 유용성을 평가하고자 기존의 필터보정역투영법(Filtered back projection, FBP)과 적응형 통계적 재구성 기법(Adaptive Statistical Iterative Reconstruction-Veo, ASIR-V)의 화질을 비교 평가하였다. FBP, ASIR-V 50%, TF-H의 재구성 기법에서 선량을 17.29 mGy로 고정한 것과 10.37 mGy, 12.10 mGy, 13.83 mGy, 15.56 mGy로 변화시킨 영상을 획득하여 노이즈, CNR, SSIM을 측정하였다. 17.29 mGy에서 재구성 기법 변화를 주었을 때 TF-H가 FBP, ASIR-V에 비해 화질이 우수하다. 선량에 변화를 주었을 때 10.37 mGy TF-H와 FBP 비교 시 노이즈, CNR, SSIM은 유의한 차이가 있고(p<0.05), 10.37 mGy TF-H와 ASIR-V 50% 비교 시 유의한 차이가 없다(p>0.05). 선량이 가장 높은 15.56 mGy ASIR-V 50%와 선량이 가장 낮은 10.37 mGy TF-H 화질이 동일하므로 TF-H는 30%의 선량 감소 효과가 있다. 따라서 딥러닝 재구성 기법(TF)은 반복적 재구성 기법(ASIR-V)과 필터보정역투영법(FBP)보다 선량을 감소시킬 수 있었다. 이로 인해 환자의 피폭선량을 감소시킬 것으로 사료된다. This study aims to evaluate the usefulness of Deep Learning Image Reconstruction (TrueFidelity, TF), the image quality of existing Filtered Back Projection (FBP) and Adaptive Statistical Iterative Reconstruction-Veo (ASIR-V) were compared. Noise, CNR, and SSIM were measured by obtaining images with doses fixed at 17.29 mGy and altered to 10.37 mGy, 12.10 mGy, 13.83 mGy, and 15.56 mGy in reconstruction techniques of FBP, ASIR-V 50%, and TF-H. TF-H has superior image quality compared to FBP and ASIR-V when the reconstruction technique change is given at 17.29 mGy. When dose changes were made, Noise, CNR, and SSIM were significantly different when comparing 10.37 mGy TF-H and FBP (p< 0.05), and no significant difference when comparing 10.37 mGy TF-H and ASIR-V 50% (p >0.05). TF-H has a dose-reduction effect of 30%, as the highest dose of 15.56 mGy ASIR-V has the same image quality as the lowest dose of 10.37 mGy TF-H. Thus, Deep Learning Reconstruction techniques (TF) were able to reduce dose compared to Iterative Reconstruction techniques (ASIR-V) and Filtered Back Projection (FBP). Therefore, it is considered to reduce the exposure dose of patients. |
Author | Joon-pyo Lee Dong-kyoon Han 한동균 Ga-hyun Kim Chan-deul Kim 이준표 김가현 Ji-soo Kim 홍주완 Joo-wan Hong 김지수 김찬들 |
Author_xml | – sequence: 1 fullname: 김가현 – sequence: 2 fullname: Ga-hyun Kim – sequence: 3 fullname: 김지수 – sequence: 4 fullname: Ji-soo Kim – sequence: 5 fullname: 김찬들 – sequence: 6 fullname: Chan-deul Kim – sequence: 7 fullname: 이준표 – sequence: 8 fullname: Joon-pyo Lee – sequence: 9 fullname: 홍주완 – sequence: 10 fullname: Joo-wan Hong – sequence: 11 fullname: 한동균 – sequence: 12 fullname: Dong-kyoon Han |
BookMark | eNo9jD1Lw1AYhe9QwVr7C1yyOAbe5H4lY4nfVoqQPeQm90JojdK4uDl0EReHSqu0tksHIUNVhP6m3ut_MKI4ncNzHs4WquWXuayhuuNzZgNzYRM1iyITgBlhjHukjs7P9oLQjB7MYGKZwVzP7iz9cfv1NKyYpYdLvVhVsdCzUt9PLfNSrj9LM3iz1qulfn8007FlJnPz_PrDzGhZrdtoQ8W9Qjb_soHCg_0wOLLbncPjoNW2uxRcm1JfKU8Cl9hzBHYYTxiWkMZYxKCI5IpwxeKECk6AukJSiEUCKgUFLBEpbqDd39tuVlxnUZ4WveikddpxwcXgA8FV8bBbeTv_XhFd9bOLuH8TEQCKHYK_Ae8Pav4 |
ContentType | Journal Article |
DBID | HZB Q5X JDI |
DEWEY | 610 |
DatabaseName | Korean Studies Information Service System (KISS) Korean Studies Information Service System (KISS) B-Type KoreaScience |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
DocumentTitleAlternate | MDCT에서 선량 변화에 따른 딥러닝 재구성 기법의 유용성 연구 |
EndPage | 46 |
ExternalDocumentID | JAKO202309043202832 4005314 |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS HZB Q5X .UV JDI P5Y |
ID | FETCH-LOGICAL-k502-559ff8e07e381b3167c63e0da3ba0f4e7f47f6ac5b74052be50abc0fd0f06cbd3 |
ISSN | 1976-0620 |
IngestDate | Fri Dec 22 12:03:32 EST 2023 Wed Feb 19 02:12:45 EST 2025 |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 1 |
Language | Korean |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-k502-559ff8e07e381b3167c63e0da3ba0f4e7f47f6ac5b74052be50abc0fd0f06cbd3 |
Notes | The Korean Society of Radiology KISTI1.1003/JNL.JAKO202309043202832 |
OpenAccessLink | http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202309043202832&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
PageCount | 10 |
ParticipantIDs | kisti_ndsl_JAKO202309043202832 kiss_primary_4005314 |
PublicationCentury | 2000 |
PublicationDate | 20230228 |
PublicationDateYYYYMMDD | 2023-02-28 |
PublicationDate_xml | – month: 02 year: 2023 text: 20230228 day: 28 |
PublicationDecade | 2020 |
PublicationTitle | 한국방사선학회 논문지 |
PublicationTitleAlternate | 한국방사선학회논문지 |
PublicationYear | 2023 |
Publisher | 한국방사선학회 |
Publisher_xml | – name: 한국방사선학회 |
SSID | ssib036466784 ssib010494110 ssib051116959 ssib012146256 ssib036279067 ssib039546180 |
Score | 1.8240896 |
Snippet | This study aims to evaluate the usefulness of Deep Learning Image Reconstruction (TrueFidelity, TF), the image quality of existing Filtered Back Projection... |
SourceID | kisti kiss |
SourceType | Open Access Repository Publisher |
StartPage | 37 |
SubjectTerms | ASIR-V FBP TrueFidelity 딥러닝 재구성 기법 적응형 통계적 재구성 기법 필터보정역투영법 |
Title | MDCT에서 선량 변화에 따른 딥러닝 재구성 기법의 유용성 연구 |
URI | https://kiss.kstudy.com/ExternalLink/Ar?key=4005314 http://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO202309043202832&dbt=JAKO&org_code=O481&site_code=SS1481&service_code=01 |
Volume | 17 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpR1Nb9Mw1Np24oJAAzE-phzwqQpyYyexj0nbMXUaCKlIu1VJ6ohq0E60PcABcegFceEwNEAb22UHpB4KCGm_aQn_gWcnTQP0wMfFfXn2e3nxc-z3Uvs9hG5zHkrHtSKTEhmaTFBmcsltM4a1mDqUCkenZNm-52w-ZM0de2dpuVLatTQahnei5wvPlfyLVgEHelWnZP9CswVTQAAM-oUSNAzlH-l4u15r4UYNCxcLogDOsKhVcsgDlI_FBubg-APkU7WtoVHHQmDBCjpdB9e-bu7Z2OczFFxkHLyaAjjAdc1dNDTKw76tAX0_v1rRKJ6z8i0sbN0abskzupqWCgAPe6JMp4VRdDnPstGsZbYVcV5b1-zJjIU1l8Ejs8ZCAx7mmejwWBqAliAgNPZczIu_ajRjobvHU4zzfuKYF2eD7gbmo2ejXmWr-2QBVc5PS8GxKPYHN7vmoN8viPLPKxYtHVdXL8R_PmFpZQG7zySORX5aetzfXrFsHckC4fwSCZzpGZMto2Uo1S7VF43Z1FlVYX5KllxV5Wu35mGSwExxRSlQP3WYA2ZKMRWD2V11hE4tWAgKRgr4MAPw2pQr0y2ZXa1L6GLuLxleNvgvo6Xd_ip6oAZ-evAmHR8a6fgkOX5lJF9ffn-_Dzgj2Z8mp2fwc5ocT5LXR0b6cXL-bZKOPxvnZ9Pky9v06J2RHp6kHz4pXHowhdorqLXRaNU2zTw3iLlrg4bAD45jLokrweIMVTSHyKGSdAIaBiRm0o2ZGztBZIcueCRWKG0ShBGJOyQmThR26FW00uv35DVkSLDdYvAbpA1dGEk3oFVJmdqeEDDLcjtraFV1Q3svi_7SzrWwhtZ1t7R7ncHjdtPbuq9GDxEqxKXO_3V9Md0NdGE-zG6ileHTkbwFdu0wXNca_QHhtHxc |
linkProvider | ISSN International Centre |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=MDCT%EC%97%90%EC%84%9C+%EC%84%A0%EB%9F%89+%EB%B3%80%ED%99%94%EC%97%90+%EB%94%B0%EB%A5%B8+%EB%94%A5%EB%9F%AC%EB%8B%9D+%EC%9E%AC%EA%B5%AC%EC%84%B1+%EA%B8%B0%EB%B2%95%EC%9D%98+%EC%9C%A0%EC%9A%A9%EC%84%B1+%EC%97%B0%EA%B5%AC&rft.jtitle=%ED%95%9C%EA%B5%AD%EB%B0%A9%EC%82%AC%EC%84%A0%ED%95%99%ED%9A%8C%EB%85%BC%EB%AC%B8%EC%A7%80&rft.au=%EA%B9%80%EA%B0%80%ED%98%84&rft.au=Ga-hyun+Kim&rft.au=%EA%B9%80%EC%A7%80%EC%88%98&rft.au=Ji-soo+Kim&rft.date=2023-02-28&rft.pub=%ED%95%9C%EA%B5%AD%EB%B0%A9%EC%82%AC%EC%84%A0%ED%95%99%ED%9A%8C&rft.issn=1976-0620&rft.volume=17&rft.issue=1&rft.spage=37&rft.externalDocID=4005314 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1976-0620&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1976-0620&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1976-0620&client=summon |