心臓手術の人工心肺復温時のトロンボエラストメトリー(ROTEM®),フィブリノゲン濃度,血小板数と輸血量,術後出血量との関連性についての検討
We measured thromboelastometry (ROTEMTM, A10: value of 10 minutes), fibrinogen concentration, and platelet counts during cardiopulmonary bypass. We estimated the necessity for blood transfusions from the end of cardiopulmonary bypass to 24 hours post-surgery in 51 patients undergoing adult cardiac s...
Saved in:
Published in | Cardiovascular Anesthesia Vol. 19; no. 1; pp. 49 - 54 |
---|---|
Main Authors | , , , , , , , , , , |
Format | Journal Article |
Language | Japanese |
Published |
一般社団法人 日本心臓血管麻酔学会
2015
Japanese Society of Cardiovascular Anesthesiologists |
Subjects | |
Online Access | Get full text |
ISSN | 1342-9132 1884-7439 |
DOI | 10.11478/jscva.2013-2-007 |
Cover
Summary: | We measured thromboelastometry (ROTEMTM, A10: value of 10 minutes), fibrinogen concentration, and platelet counts during cardiopulmonary bypass. We estimated the necessity for blood transfusions from the end of cardiopulmonary bypass to 24 hours post-surgery in 51 patients undergoing adult cardiac surgery. The values that indicated the necessity for fresh frozen plasma were FIBTEM (A10) <6 mm and fibrinogen concentration<145 mg/dl. The values that indicated the necessity for platelet concentrates were platelet counts <80,000/μl and [EXTEM (A10)-FIBTEM (A10)] <30 mm. The results of this study indicate that, 1) FIBTEM (A10) estimates the necessity for fresh frozen plasma as well as fibrinogen concentration, 2) [EXTEM (A10)-FIBTEM (A10)] and platelet counts estimates the necessity for platelet concentrate, and 3) normalization of fibrinogen concentration >200 mg/dl or FIBTEM (A10) >10 mm and normalization of platelet counts >80,000/μl or [EXTEM (A10)-FIBTEM (A10)] >30 mm decreases the amount of post-operative bleeding by 30~50%.
本稿の内容の一部は,第 17 回日本心臓血管麻酔学会学術大会•総会(2012 年 9 月 15 日仙台市),藤田昌雄賞候補セッション,ポスターセッション(止血•凝固 2)にて発表し,藤田昌雄賞を受賞した。 |
---|---|
ISSN: | 1342-9132 1884-7439 |
DOI: | 10.11478/jscva.2013-2-007 |