Orthopaedic Physical Examination Assisting System for Improvement of Accuracy and Reproducibility of Knee Laxity Diagnosis
In this study, to improve accuracy and reproducibility of knee laxity diagnosis, Orthopaedic physical examination assisting system was developed. The system enables the surgeon to monitor the force vector added by himself and the posture of the knee in real-time. The advantage of the developed syste...
Saved in:
Published in | TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C Vol. 77; no. 773; pp. 138 - 148 |
---|---|
Main Authors | , , , , , , , |
Format | Journal Article |
Language | Japanese |
Published |
The Japan Society of Mechanical Engineers
2011
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | In this study, to improve accuracy and reproducibility of knee laxity diagnosis, Orthopaedic physical examination assisting system was developed. The system enables the surgeon to monitor the force vector added by himself and the posture of the knee in real-time. The advantage of the developed system is to quantify the normal orthopaedic physical examination, without any modification, which is accustomed to general orthopaedic surgeons. The force vector added to the shank by a surgeon is measured with 3 axis force sensor and 6DOF magnetic tracker FASTRAK, and 6DOF knee joint motion of the patient is measured with two FASTRAK receivers which are attached on its thigh and shank. In this system, to describe the 6DOF knee motion, Femoral and tibial coordinate systems are defined with bony landmark which is easily palpated and are registered to the thigh or shank receiver coordinate system by homogeneous transformation matrix which is acquired by the special stylus. To evaluate the effectiveness of the system, the posterior drawer test with the system was done by 5 young healthy people. The evaluation parameters were knee posture, load magnitude and load position during the experiment. The result showed examination accuracy was significantly improved in all evaluation parameters. |
---|---|
AbstractList | In this study, to improve accuracy and reproducibility of knee laxity diagnosis, Orthopaedic physical examination assisting system was developed. The system enables the surgeon to monitor the force vector added by himself and the posture of the knee in real-time. The advantage of the developed system is to quantify the normal orthopaedic physical examination, without any modification, which is accustomed to general orthopaedic surgeons. The force vector added to the shank by a surgeon is measured with 3 axis force sensor and 6DOF magnetic tracker FASTRAK, and 6DOF knee joint motion of the patient is measured with two FASTRAK receivers which are attached on its thigh and shank. In this system, to describe the 6DOF knee motion, Femoral and tibial coordinate systems are defined with bony landmark which is easily palpated and are registered to the thigh or shank receiver coordinate system by homogeneous transformation matrix which is acquired by the special stylus. To evaluate the effectiveness of the system, the posterior drawer test with the system was done by 5 young healthy people. The evaluation parameters were knee posture, load magnitude and load position during the experiment. The result showed examination accuracy was significantly improved in all evaluation parameters. |
Author | FUJIE, Masakatsu G. KAWAMURA, Kazuya MURATSU, Hirotsugu KUBO, Seiji KUROSAKA, Masahiro MATSUMOTO, Tomoyuki OKAMOTO, Jun KUMASAKA, Yu |
Author_xml | – sequence: 1 fullname: OKAMOTO, Jun organization: Faculty of Engineering, Tokyo University of Agriculture and Technology – sequence: 2 fullname: KUMASAKA, Yu – sequence: 3 fullname: KAWAMURA, Kazuya – sequence: 4 fullname: MATSUMOTO, Tomoyuki – sequence: 5 fullname: KUBO, Seiji – sequence: 6 fullname: MURATSU, Hirotsugu – sequence: 7 fullname: KUROSAKA, Masahiro – sequence: 8 fullname: FUJIE, Masakatsu G. |
BookMark | eNo9UFtPwjAYbYwmIvLoe__AsKPruj0SBCWSaLw8L9_ar1DYOtIVw_z1jqAmJzk5OZeHc0MuXeOQkLuYjeNJnt_v7A6sGks5jnl2QQZxliVRxkVyTUZta0vG0pQnPEkH5PvFh02zB9RW0ddN11oFFZ0fobYOgm0cnfaNNli3pu9dG7CmpvF0We9984U1ukAbQ6dKHTyojoLT9A17Tx-ULW1lQ3fynx0iXcHxJB8srF3Tb96SKwNVi6NfHpLPxfxj9hStXh6Xs-kq2sY5C5FOkjLHVErB0aRMmlgAK5WRLIMsFwJFghOpYtAsB5EanfGUiVKXuRblxBg-JIvz7rYNsMZi720NvivAB6sqLM5vFVL24H_UH_cfUBvwBTr-Aw9qcE8 |
ContentType | Journal Article |
Copyright | 2011 The Japan Society of Mechanical Engineers |
Copyright_xml | – notice: 2011 The Japan Society of Mechanical Engineers |
DOI | 10.1299/kikaic.77.138 |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1884-8354 |
EndPage | 148 |
ExternalDocumentID | article_kikaic_77_773_77_773_138_article_char_en |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS JSF KQ8 RJT |
ID | FETCH-LOGICAL-j190t-d44b9e67753ef607f15a0bcf708a8955e54e27c1ad09a56fd83605bdb9d5b2ff3 |
IngestDate | Wed Apr 05 14:45:28 EDT 2023 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 773 |
Language | Japanese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-j190t-d44b9e67753ef607f15a0bcf708a8955e54e27c1ad09a56fd83605bdb9d5b2ff3 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/kikaic/77/773/77_773_138/_article/-char/en |
PageCount | 11 |
ParticipantIDs | jstage_primary_article_kikaic_77_773_77_773_138_article_char_en |
PublicationCentury | 2000 |
PublicationDate | 2011 |
PublicationDateYYYYMMDD | 2011-01-01 |
PublicationDate_xml | – year: 2011 text: 2011 |
PublicationDecade | 2010 |
PublicationTitle | TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C |
PublicationTitleAlternate | Trans.JSME, C |
PublicationYear | 2011 |
Publisher | The Japan Society of Mechanical Engineers |
Publisher_xml | – name: The Japan Society of Mechanical Engineers |
References | (5) Kowalk, D.L., Wojtys, E.M., Disher, J., Loubert, P., “The relationships between instrumented measurements of ankle and knee ligamentous laxity and generalized joint laxity”, The American Journal of Sports Medicine, Vol.21-No.5, (1993), pp.744-747. (18) Teghtsoonian, R., “On the exponents in Stevens’ law and the constant in Ekman’s law”, Psychological Review, Vol.78-No.1, (1971), pp.71-80. (4) Lerat, J.L., Moyen, B., Jenny, J.Y., Perrier, J.P., “A comparison of pre-operative evaluation of anterior knee laxity by dynamic X-rays and by the arthrometer KT 1000”, Knee Surgery, Sports Traumatology, Arthroscopy, Vol.1-No.1, (2005), pp.54-59. (6) Pearsall, A.W., Kovaleski, J.E., Heitman, R.J., Gurchiek, L.R., Hollis, J.M., “Quantitative analysis of the measuring capabilities of the KT-1000 knee ligament arthrometer”, The Journal of Sports Medicine and Physical Fitness, Vol.46-No.1, (1993), pp.104-110. (2) 宗田大, 実践すぐに役立つ膝靱帯損傷診断・治療マニュアル, (2006), 全日本病院出版会. (10) Grood, E.S., Suntay, W.J., “A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee”, Journal of Biomechanical Engineering, Vol.105-No.2, (1983), pp.136-144. (1) Cipriano, J.J., Photographic Manual of Regional Orthopaedic and Neurologic Tests, (2010), Lippincott Williams and Wilkins. (14) Markolf, K.L., Kochan, A., Amstutz, H.C., “Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament”, Journal of Bone Joint Surgery, Vol.66-No.2, (1984), pp.242-252. (16) Kitami, K., Fujie, H., Isao, M., “Use of robotic technology to measure anterior instability of human knee joint : A biomechanical study using amputated knees”, Kitasato medicine, Vol.25-No.3, (1995), pp.259-266. (11) Hoshino, Y., Kuroda, K., Nagamune, K., Kurosaka, M., “In vivo measurement of the pivot-shift test in the anterior cruciate ligament-deficient knee using an electromagnetic device”, The American Journal of Sports Medicine, Vol.35-No.7, (2007), pp.1098-1104. (13) Markolf, K.L., Mensch, J.S., Amstutz, H.C., “Stiffness and laxity of the knee-the contributions of the supporting structures. A quantitative in vitro study”, Journal of Bone Joint Surgery, Vol.58-No.5, (1976), pp.583-594. (3) Harner, C.D., Vince, K.G, Fu, F.H., Knee Surgery, (1994), Williams and Wilkins. (17) 高岡邦夫, 整形外科徒手検査法, (2003), メジカルビュー社. (7) 牧田忍, 浦岡繁宣, 升谷保博, 西村敦, “理学療法士の養成を支援する下肢ロボットの膝関節トルクモデルの検討”, 福祉工学シンポジウム講演論文集2005, (2005), pp.221-224. (8) 菊池武士, 小田邦彦, 山口紗代, 古荘純次, “コンパクトMR 流体クラッチを用いた足部痙性シミュレータの開発”, 日本ロボット学会誌, Vol.27-No.8, (2009), pp.933-941. (12) Fujie, H., Kashiwaguchi, S., Glen, L.A., “Magnitude and Distribution of the In Situ Force in the Human Anterior Cruciate Ligament during a Joint Instability Test (Lachman Test)”, Transactions of the Japan Society of Mechanical Engineers. A, Vol.60-No.578, (1994), pp.2459-2463. (15) 藤江裕道, 渡辺尚, 塚本行男, 笹田直, 馬渕清資, “膝関節動揺性試験における膝靱帯の張力分布: ロボティクスを用いた計測”, 日本機械学會論文集. C 編, Vol.61-No.586, (1995), pp.2521-2526. (9) 林祐介, 平野達也, 河合祐樹, 山崎一徳, 森田良文, 鵜飼裕之, 左中孝二, 中牟田祐典, 高尾恵子, “療法士養成のための膝関節ロボットの開発”, 日本機械学会ロボティクス・メカトロニクス講演会2010, (2010), 1P1-E19. |
References_xml | |
SSID | ssib006634346 ssj0000608103 |
Score | 1.8996047 |
Snippet | In this study, to improve accuracy and reproducibility of knee laxity diagnosis, Orthopaedic physical examination assisting system was developed. The system... |
SourceID | jstage |
SourceType | Publisher |
StartPage | 138 |
SubjectTerms | Bio-Motion Biomechanics Knee Laxity Diagnosis Magnetic Tracker Medical and Welfare Assistance Medical Quantitation Orthopaedic Physical Examination Weber Ratio |
Title | Orthopaedic Physical Examination Assisting System for Improvement of Accuracy and Reproducibility of Knee Laxity Diagnosis |
URI | https://www.jstage.jst.go.jp/article/kikaic/77/773/77_773_138/_article/-char/en |
Volume | 77 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C, 2011, Vol.77(773), pp.138-148 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3Pb9MwFLbKuMAB8VOMAfKBG0pJGidpT8gaRWUlLaypGKfKdmzRVrRT10hb_2v-A96zkzQDDgykKG3dxI38vvo929_7TMgrFYe57snQ00p2PabywBMQ6nsKnLXfySEEiTDfOR3Fgyk7OYvOWq0fDdZSsZVttftjXsm_WBXKwK6YJXsDy9aVQgG8B_vCGSwM57-y8Xiz_QaDXlxrsZvY2AbvXwqkt1i7QuPjfxhFt61isyUVunkEXbEAuFLFBjd9d6mK51YC1nFm7er7cKX164_iEj--c8S8-UUzps1O-WjiyCiTikR0wj_xEcosfOhnX7Ew7R8P-MiKL1RaVhPsqGCgvp-oHQ95Os7GLltkTw-YpnzCh9x6i6Iu5V94Oj3ljhKyK65q_5LyDHxFWU-2_r6-Kpbz5uxGsJ_XsJlxEC-savoqUoI0pkO7xizlGktJd9d7d7vMw5msZvde7hLjYJwkYaO3DpywTOn4Ayf5-ZtPAYcNQFjOl2Ku2knSru-6JtNdgmDmrpslCRxh9QK3zKoLMJsOwHuL3O5A34gs1OHnRhcYhywsR-gumICYzQ9LdVh4lDfXHgTipgWMIioGog2KsvvkXjmaodz96APSWoiH5G5D4_IR2TVASiuQ0gZIaQ1S6kBKAaS0AVK6NrQCKQWQ0l9Ait8jSKkDKa1B-phM3_ez44FXbvjhLSAu3Xo5Y7Kn4wSG0NrEfmKCSPhSmcTvim4vinTEdCdRgcj9nohik2MGUiRz2csj2TEmfEIOVuuVfkqoESZUmP0kA8nAyQghwPNoxQxjJmCdQ_LWNdzs3Km6zG5qwGf_XcMRueNWKPB4Tg62m0K_gBB3K19aUPwEXQ6wyA |
link.rule.ids | 315,783,787,4031,27935,27936,27937 |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Orthopaedic+Physical+Examination+Assisting+System+for+Improvement+of+Accuracy+and+Reproducibility+of+Knee+Laxity+Diagnosis&rft.jtitle=TRANSACTIONS+OF+THE+JAPAN+SOCIETY+OF+MECHANICAL+ENGINEERS+Series+C&rft.au=OKAMOTO%2C+Jun&rft.au=KUMASAKA%2C+Yu&rft.au=KAWAMURA%2C+Kazuya&rft.au=MATSUMOTO%2C+Tomoyuki&rft.date=2011&rft.pub=The+Japan+Society+of+Mechanical+Engineers&rft.eissn=1884-8354&rft.volume=77&rft.issue=773&rft.spage=138&rft.epage=148&rft_id=info:doi/10.1299%2Fkikaic.77.138&rft.externalDocID=article_kikaic_77_773_77_773_138_article_char_en |