Incidence, Risk Factors, and Outcomes of Coronary Obstruction Following Valve-in-Valve Transcatheter Aortic Valve Replacement
There is scant information about the incidence, risk factors, and outcomes of coronary obstruction (CO) following valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). A meta-analysis of the published studies from January 2000 to April 2020 was conducted, and the endpoint was CO. A total...
Saved in:
Published in | International heart journal Vol. 62; no. 1; p. 104 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Japan
30.01.2021
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Abstract | There is scant information about the incidence, risk factors, and outcomes of coronary obstruction (CO) following valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). A meta-analysis of the published studies from January 2000 to April 2020 was conducted, and the endpoint was CO. A total of 2858 patients were enrolled in this study. The mean age was 77.7 ± 9.8, and 39.9% of them were female. The Society of Thoracic Surgeons (STS) score, European System for Cardiac Operative Risk Evaluation (EuroSCORE), and Logistic EuroSCORE were 8.9 ± 7.8, 16.0 ± 10.9, and 26.3 ± 16.3, respectively. The overall incidence of CO was 2.58%. CO incidence between patients with prior stented and stentless valves were significantly different (1.67% versus 7.17%), with an odds ratio (OR) of 0.25 and a 95% confidence interval (CI) of 0.14-0.44 (P < 0.00001). The first-generation valves were significantly associated with higher CO incidence compared with the second-generation valves (7.09% versus 2.03%; OR, 2.44; 95%CI, 1.06-5.62; P = 0.04), while no statistical difference was found between self-expandable valves and balloon-expandable valves (2.45% versus 2.60%; OR, 0.99; 95%CI, 0.55-1.79; P = 0.98). Virtual transcatheter to coronary ostia (VTC) distance (3.3 ± 2.1 mm, n = 29 versus 5.8 ± 2.4 mm, n = 169; mean difference, -2.70; 95%CI, -3.46 to -1.95; P < 0.00001) and the sinus of Valsalva (SOV) diameter (27.5 ± 3.8 mm, n = 23 versus 32.3 ± 4.0 mm, n = 101; mean difference, -3.80; 95%CI, -6.55 to -1.05; P = 0.007) were enormously shorter in patients with CO. The 24-hour, in-hospital, and 30-day mortality of patients with CO were 10.5%, 30.8%, and 37.1%, respectively. In conclusion, device selections, VTC distances, and SOV diameters may be important factors in assessing the CO risk in VIV-TAVR. |
---|---|
AbstractList | There is scant information about the incidence, risk factors, and outcomes of coronary obstruction (CO) following valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). A meta-analysis of the published studies from January 2000 to April 2020 was conducted, and the endpoint was CO. A total of 2858 patients were enrolled in this study. The mean age was 77.7 ± 9.8, and 39.9% of them were female. The Society of Thoracic Surgeons (STS) score, European System for Cardiac Operative Risk Evaluation (EuroSCORE), and Logistic EuroSCORE were 8.9 ± 7.8, 16.0 ± 10.9, and 26.3 ± 16.3, respectively. The overall incidence of CO was 2.58%. CO incidence between patients with prior stented and stentless valves were significantly different (1.67% versus 7.17%), with an odds ratio (OR) of 0.25 and a 95% confidence interval (CI) of 0.14-0.44 (P < 0.00001). The first-generation valves were significantly associated with higher CO incidence compared with the second-generation valves (7.09% versus 2.03%; OR, 2.44; 95%CI, 1.06-5.62; P = 0.04), while no statistical difference was found between self-expandable valves and balloon-expandable valves (2.45% versus 2.60%; OR, 0.99; 95%CI, 0.55-1.79; P = 0.98). Virtual transcatheter to coronary ostia (VTC) distance (3.3 ± 2.1 mm, n = 29 versus 5.8 ± 2.4 mm, n = 169; mean difference, -2.70; 95%CI, -3.46 to -1.95; P < 0.00001) and the sinus of Valsalva (SOV) diameter (27.5 ± 3.8 mm, n = 23 versus 32.3 ± 4.0 mm, n = 101; mean difference, -3.80; 95%CI, -6.55 to -1.05; P = 0.007) were enormously shorter in patients with CO. The 24-hour, in-hospital, and 30-day mortality of patients with CO were 10.5%, 30.8%, and 37.1%, respectively. In conclusion, device selections, VTC distances, and SOV diameters may be important factors in assessing the CO risk in VIV-TAVR. |
Author | Qian, Dehui Gao, Zhichun Jin, Jun Wang, Yong |
Author_xml | – sequence: 1 givenname: Zhichun surname: Gao fullname: Gao, Zhichun organization: Department of Cardiology, Xinqiao Hospital, Army Medical University (Third Military Medical University) – sequence: 2 givenname: Yong surname: Wang fullname: Wang, Yong organization: Department of Cardiology, Xinqiao Hospital, Army Medical University (Third Military Medical University) – sequence: 3 givenname: Dehui surname: Qian fullname: Qian, Dehui organization: Department of Cardiology, Xinqiao Hospital, Army Medical University (Third Military Medical University) – sequence: 4 givenname: Jun surname: Jin fullname: Jin, Jun organization: Department of Cardiology, Xinqiao Hospital, Army Medical University (Third Military Medical University) |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/33455986$$D View this record in MEDLINE/PubMed |
BookMark | eNo1kMtKAzEYhYMoWqsbH0DyAE2dXOaSZSlWC4WBUt2WXP6xqTPJkEkVF767xerqnMXhg-9co3MfPCB0R7MpzXnx4Hb7KcuIyOgZGlEuJOFMykt0xbnIc1kVI_S99MZZ8AYmeO2Gd7xQJoU4TLDyFteHZEIHAw4NnocYvIpfuNZDigeTXPB4Edo2fDr_hl9V-wHEefJb8CYqPxiVdpAg4lmIyZnTBq-hb5WBDny6QReNage4_csxelk8bubPZFU_LeezFdnTvKLkKMNkUZZcM604pyJnWQalrHhTVMYClZw1wlhJtbYKrC6haHTOTJkJzUTDxuj-xO0PugO77aPrjirb_x_YD-CPXYE |
ContentType | Journal Article |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1536/ihj.20-401 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
EISSN | 1349-3299 |
ExternalDocumentID | 33455986 |
Genre | Meta-Analysis Comparative Study Systematic Review Journal Article |
GroupedDBID | CGR CUY CVF ECM EIF NPM |
ID | FETCH-LOGICAL-j1581-153296773b2ba33145200e7983f68cde1932f4cd91bbdaedb7e6fb52c704b24f2 |
IngestDate | Thu Jan 02 22:57:49 EST 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Keywords | Aortic stenosis Stentless valves New-generation valves |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-j1581-153296773b2ba33145200e7983f68cde1932f4cd91bbdaedb7e6fb52c704b24f2 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/ihj/62/1/62_20-401/_pdf |
PMID | 33455986 |
ParticipantIDs | pubmed_primary_33455986 |
PublicationCentury | 2000 |
PublicationDate | 2021-Jan-30 |
PublicationDateYYYYMMDD | 2021-01-30 |
PublicationDate_xml | – month: 01 year: 2021 text: 2021-Jan-30 day: 30 |
PublicationDecade | 2020 |
PublicationPlace | Japan |
PublicationPlace_xml | – name: Japan |
PublicationTitle | International heart journal |
PublicationTitleAlternate | Int Heart J |
PublicationYear | 2021 |
Score | 2.2214088 |
SecondaryResourceType | review_article |
Snippet | There is scant information about the incidence, risk factors, and outcomes of coronary obstruction (CO) following valve-in-valve transcatheter aortic valve... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 104 |
SubjectTerms | Aged Aged, 80 and over Aortic Valve Stenosis - surgery Bioprosthesis - adverse effects Coronary Artery Bypass - methods Coronary Artery Bypass - statistics & numerical data Coronary Occlusion - epidemiology Coronary Occlusion - mortality Coronary Occlusion - surgery Female Heart Valve Prosthesis - trends Hospital Mortality Humans Incidence Male Percutaneous Coronary Intervention - methods Percutaneous Coronary Intervention - statistics & numerical data Postoperative Complications - epidemiology Prosthesis Design Risk Factors Sinus of Valsalva - diagnostic imaging Stents Tomography, X-Ray Computed - methods Transcatheter Aortic Valve Replacement - adverse effects Transcatheter Aortic Valve Replacement - instrumentation |
Title | Incidence, Risk Factors, and Outcomes of Coronary Obstruction Following Valve-in-Valve Transcatheter Aortic Valve Replacement |
URI | https://www.ncbi.nlm.nih.gov/pubmed/33455986 |
Volume | 62 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9wwELaWIlVcqlb0_ZAP3Ba3OHbszRGhrlAlCgdogQuyE1ubbbtBYpdKlfov-oM7YzvZAK1ouURR7MSK5_NkZjL-hpANV1huRs6wLV0aJnNhmclFznilVOFUYX1I-d_7qHaP5Ifj_Hgw-NXLWlrM7dvyxx_3ldxFqnAN5Iq7ZP9Dst1D4QKcg3zhCBKG4z_JGBZ3rAkat8hffBmOY_mcNidzfzGHcSOv7A5yFWCO3L7tSGOHY4BB8x3DBZ_M10vH6hkLJ5H0PHC6IovidoODxz5os2PsvUuZmS6T4ZexRSyUPR_23wKTfEwIzJ5O6nKy6FD5OYWsT5r0FcU4bG2SOpws6i7LJ1UOS7emWEWGgYr2t4uL-lXIgoks1kRqFbDKbgAtatNUmfiGls9DGZp6MgX_Hhxg3u8EEjr_FuQthAzs87e3XmPcbptWyAr4HlhM9WAvMdvCyO-W466R-23fa15JsE4OH5IHya2g2xEjj8jAzdbJzw4fmxTRQRM6Nilgg7bYoI2nLTZoDxu0wwa9ig16BRs0YiP2oT1sPCZH4_eHO7ssldtgU56POIOXywqltbCZNUJwiYxcThcj4dWorBya-l6WVcGtrYxDXm7lbZ6VekvaTPrsCbk3a2buGaHOcQ9-vNRKgn0ruc05PMgoLQtdaS-fk6dxts7OI6fKWTuPL_7a8pKsLSH1iqx6WMTuNViEc_smiOg3gahmSA |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Incidence%2C+Risk+Factors%2C+and+Outcomes+of+Coronary+Obstruction+Following+Valve-in-Valve+Transcatheter+Aortic+Valve+Replacement&rft.jtitle=International+heart+journal&rft.au=Gao%2C+Zhichun&rft.au=Wang%2C+Yong&rft.au=Qian%2C+Dehui&rft.au=Jin%2C+Jun&rft.date=2021-01-30&rft.eissn=1349-3299&rft.volume=62&rft.issue=1&rft.spage=104&rft_id=info:doi/10.1536%2Fihj.20-401&rft_id=info%3Apmid%2F33455986&rft_id=info%3Apmid%2F33455986&rft.externalDocID=33455986 |