Removal Rates of Formaldehyde and NO2 by Air Cleaners
Removal rates of formaldehyde and NO2 by 13 kinds of air cleaners were derived from the decrease of formaldehyde and NO2 concentrations in a small chamber. The differences in function were large among them. Removal rates of formaldehyde for 10 kinds of filter-type air cleaners ranged from 3% to 45%...
Saved in:
Published in | SEIKATSU EISEI (Journal of Urban Living and Health Association) Vol. 44; no. 2; pp. 65 - 72 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English Japanese |
Published |
Osaka Urban Living and Health Association
2000
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Removal rates of formaldehyde and NO2 by 13 kinds of air cleaners were derived from the decrease of formaldehyde and NO2 concentrations in a small chamber. The differences in function were large among them. Removal rates of formaldehyde for 10 kinds of filter-type air cleaners ranged from 3% to 45% on condition of “high”. Removal rate of NO2 by 6 kinds of filter-type air cleaners ranged from 1.2% to 42% on condition of “high”. Apparent removal rates of formaldehyde for same air clearmers obtained in an actual room were low in comparison with removal rates obtained in the small chamber. Latter removal rates ranged from 13% to 36%, whereas the former removal rates ranged from 1.9% to 3.9%. The differences between them were thought to result from the increase of formaldehyde generation caused by the variations of room temperature and air flow, the variation of air exchange rate and the phenomena of adsorption toward wall and floor surface and desorption from those. With regard to the effect of air cleaner in actual room, the efficiency was low as shown by the following result: formaldehyde concentration was decreased from 0.16ppm to 0.11ppm by using air clearner D. |
---|---|
AbstractList | Removal rates of formaldehyde and NO2 by 13 kinds of air cleaners were derived from the decrease of formaldehyde and NO2 concentrations in a small chamber. The differences in function were large among them. Removal rates of formaldehyde for 10 kinds of filter-type air cleaners ranged from 3% to 45% on condition of “high”. Removal rate of NO2 by 6 kinds of filter-type air cleaners ranged from 1.2% to 42% on condition of “high”. Apparent removal rates of formaldehyde for same air clearmers obtained in an actual room were low in comparison with removal rates obtained in the small chamber. Latter removal rates ranged from 13% to 36%, whereas the former removal rates ranged from 1.9% to 3.9%. The differences between them were thought to result from the increase of formaldehyde generation caused by the variations of room temperature and air flow, the variation of air exchange rate and the phenomena of adsorption toward wall and floor surface and desorption from those. With regard to the effect of air cleaner in actual room, the efficiency was low as shown by the following result: formaldehyde concentration was decreased from 0.16ppm to 0.11ppm by using air clearner D. |
Author | MIYAZAKI, Takeji KAWARAYA, Toshio FUNASAKA, Kunihiro TSURUHO, Kenshiro |
Author_xml | – sequence: 1 fullname: MIYAZAKI, Takeji organization: Osaka City Institute of Public Health and Environmental Sciences – sequence: 2 fullname: FUNASAKA, Kunihiro organization: Osaka City Institute of Public Health and Environmental Sciences – sequence: 3 fullname: KAWARAYA, Toshio organization: Osaka City Institute of Public Health and Environmental Sciences – sequence: 4 fullname: TSURUHO, Kenshiro organization: Osaka City Institute of Public Health and Environmental Sciences |
BookMark | eNplj81Kw0AUhQepYFp9h3mB1LmZv2RZilUhWCjdhzszNzY1TWQmCn17hUo3bs75FocPzpzNhnEgxjiIJYAy5WOi7gOn9EXdL0Gl7VKppdE3LIOylLkxEmYsE7oscgXW3LF5SkchFGjQGdM7Oo3f2PMdTpT42PLNGE_YBzqcA3EcAn_bFtyd-aqLfN0TDhTTPbttsU_08NcLtt887dcveb19fl2v6vwIWou8aivRQotgvMVAVekdWlcFEOi81zJ4I5VGXVrrgvSFkRU5sK0LwkCh5ILVF-0xTfhOzWfsThjPDcap8z01_643SjXFJYy-zvwBY0OD_AE_WFxQ |
ContentType | Journal Article |
Copyright | Osaka Urban Living and Health Association |
Copyright_xml | – notice: Osaka Urban Living and Health Association |
DOI | 10.11468/seikatsueisei1957.44.65 |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Public Health |
EISSN | 1883-6631 |
EndPage | 72 |
ExternalDocumentID | article_seikatsueisei1957_44_2_44_2_65_article_char_en |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS JSF KQ8 OK1 RJT |
ID | FETCH-LOGICAL-j1550-9f90f1fa16c7ade98cba7b9d10abcc53dc6345a5877bd3c2639eb17fbd061243 |
ISSN | 0582-4176 |
IngestDate | Wed Apr 05 06:06:01 EDT 2023 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 2 |
Language | English Japanese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-j1550-9f90f1fa16c7ade98cba7b9d10abcc53dc6345a5877bd3c2639eb17fbd061243 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/seikatsueisei1957/44/2/44_2_65/_article/-char/en |
PageCount | 8 |
ParticipantIDs | jstage_primary_article_seikatsueisei1957_44_2_44_2_65_article_char_en |
PublicationCentury | 2000 |
PublicationDate | 2000 |
PublicationDateYYYYMMDD | 2000-01-01 |
PublicationDate_xml | – year: 2000 text: 2000 |
PublicationDecade | 2000 |
PublicationTitle | SEIKATSU EISEI (Journal of Urban Living and Health Association) |
PublicationTitleAlternate | SEIKATSU EISEI |
PublicationYear | 2000 |
Publisher | Osaka Urban Living and Health Association |
Publisher_xml | – name: Osaka Urban Living and Health Association |
References | 1) 宮崎竹二: 住宅内ホルムアルデヒド濃度, 生活衛生, 40, 353-361, 1996 3) 宮崎竹二: 住まいと化学物質について, 消費者情報 No. 301, 22-25, 1999 10) 野崎淳夫: 新築住宅の室内化学物質汚染低減化対策について, 建築設備と配管工事, 18-25, 1999. 8 12) ビル管理教育センター編: 空調設備の維持管理指針-空気環境管理のために-, 18, 1982 5) 大村道雄, 入江建久他: 室内空気清浄機の性能比較 (その3) ファン・フィルタ式とイオン・ファン式の比較, 日本建築学会大会学術講演梗概集D-II, 741-742, 1998 7) 読売新聞1999年9月14日朝刊 9) 呂俊民他: 室内の空気質に関する研究, その5 空気清浄機の効果, 日本建築学会大会学術講演梗概集D-II, 749-750, 1999 11) 環境庁大気保全局大気規制課: 大気汚染物質測定法指針, 415-418, 環境公害新聞社, 1987 6) 南野脩他: 小型空気清浄器とその応用に関する研究, 第1報―浮遊粉じん除去性能に関する研究, 空気調和 2) 宮崎竹二他: ホルムアルデヒド濃度の実測事例, 全国公害研会誌, 23, 153-161, 1998 4) 宮崎竹二他: 沿道周辺住宅の室内空気汚染, 大阪市立環境科学研究所調査研究年報, 58, 7-17, 1996 8) 関根嘉香他: ホルムアルデヒド除去用空気清浄器の性能評価, 資源環境対策, 35 (5), 441-446, 1999 |
References_xml | |
SSID | ssj0041515 |
Score | 1.4680943 |
Snippet | Removal rates of formaldehyde and NO2 by 13 kinds of air cleaners were derived from the decrease of formaldehyde and NO2 concentrations in a small chamber. The... |
SourceID | jstage |
SourceType | Publisher |
StartPage | 65 |
SubjectTerms | air cleaner formaldehyde nitrogen dioxide (NO2) removal rate |
Title | Removal Rates of Formaldehyde and NO2 by Air Cleaners |
URI | https://www.jstage.jst.go.jp/article/seikatsueisei1957/44/2/44_2_65/_article/-char/en |
Volume | 44 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | SEIKATSU EISEI (Journal of Urban Living and Health Association), 2000/03/30, Vol.44(2), pp.65-72 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1bb9MwFLbKeEFCiKsYG8gPvE0pudi5PFpTp5ZqnWgTsfES2U6iphsJ6mXS-J_8H45jJwQNpDHxYllJ7Tj9Ph1_ds45Rui9gEmg8KLcEtLxLBIJqBEaWlRmnk8cGdnNcW-nM3-ckI_n9Hww-NHzWtptxVB-_2NcyX1QhWuAq4qS_Qdku07hAtQBXygBYSjvhPE8_1pfq-z4SjAq2XeiFOhVli9vMv1ZYHbmKoHJyvXR8VXOK-Pv3srRxWgyZfEiORpNoKrUZk-gJmuhzvQtr9s4RhOy1EO0t49wOrlgX9h00hCAX-arsqNGMmMLNmWNTdlV5bJc152dZ5_ZnF009-J6syy7OzCqeTI-M7FDm65Ru0Nh_1rJbvglv8toe0aPguInTmDSY2ujHIaeBcrI6VttnTXSsNPtmWB99ISZzPWxQLenCeKr2IdNrqK0oIMSak5EgyEhw7b9b0m4DcTprRYpIamrC5-m7c9UxBwQ9AF66IL9U56m00_dxy2iNKQSCO2rtg5mMKgPfxkS6KMVrBZaT8NG_MRP0RNDCsz0g5-hQV49R4_1li_Wf_QLRA0dcUNHXBe4T0cMmGCgIxY3GOiIWzq-RPHJKD4eW-ZUDmullrNWVER24RTc8WXAszwKpeCBiDLH5kJK6mXS9wjlNAwCkXnSBQkMeiAoRKbUNPFeob2qrvLXCNvSVtkWqQiETSSsn0LheTQSDi1ANXKyj0b6pdNvOvNKej8Y3vynfg7QI52IQW3AHaK97XqXvwVJuhXvGoB_Anh6khk |
link.rule.ids | 315,783,787,4031,27935,27936,27937 |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Removal+Rates+of+Formaldehyde+and+NO2+by+Air+Cleaners&rft.jtitle=SEIKATSU+EISEI+%28Journal+of+Urban+Living+and+Health+Association%29&rft.au=MIYAZAKI%2C+Takeji&rft.au=FUNASAKA%2C+Kunihiro&rft.au=KAWARAYA%2C+Toshio&rft.au=TSURUHO%2C+Kenshiro&rft.date=2000&rft.pub=Osaka+Urban+Living+and+Health+Association&rft.issn=0582-4176&rft.eissn=1883-6631&rft.volume=44&rft.issue=2&rft.spage=65&rft.epage=72&rft_id=info:doi/10.11468%2Fseikatsueisei1957.44.65&rft.externalDocID=article_seikatsueisei1957_44_2_44_2_65_article_char_en |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0582-4176&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0582-4176&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0582-4176&client=summon |