Non-physiological rate response in the pacemaker using activity sensor: assessment by rate profile and redraw function

Non-physiological rate response in the pacemaker using activity sensor assessment by rate profile and redraw function. Rate response in the pacemaker using activity sensor is not uniform in the daily activities. We studied the effects of slope, jogging, stairs on rate response quality of SSIR pacema...

Full description

Saved in:
Bibliographic Details
Published inJinko Zoki Vol. 24; no. 2; pp. 456 - 461
Main Author YAMAMOTO Y
Format Journal Article
LanguageJapanese
Published 一般社団法人 日本人工臓器学会 1995
JAPANESE SOCIETY FOR ARTIFICIAL ORGANS
Subjects
Online AccessGet full text
ISSN0300-0818
1883-6097
DOI10.11392/jsao1972.24.456

Cover

Abstract Non-physiological rate response in the pacemaker using activity sensor assessment by rate profile and redraw function. Rate response in the pacemaker using activity sensor is not uniform in the daily activities. We studied the effects of slope, jogging, stairs on rate response quality of SSIR pacemaker DASH (Intermedics Ltd), using internal rate profile and redraw functions. Exercise tests were performed by three protocols. Protocol (1) includes walk on treadmill with slope of 0% and 14% at 2.0mph and 3.4mph for 3min at each stage of exercise. Protocol (2) includes walk on treadmill with 0% slope at 2.0mph, 3.4mph, 4.2mph and jog at 4.2mph. Protocol (3) includes walk and Master two steps tests with constant speed of 100 steps/min. Sinus rate and activity sensor rate profiles of different settings of rate response parameters were compared. As the result, if rate response parameters were set optimal to walk speed, sensor rate was under-responsive both to slope and stairs, and over responsive to jogging. Thus, one setting of rate response parameters was not optimal to all of daily activities. This is a limitation of rate response quality by activity sensor. 坂道歩行、階段歩行、駆け足に対する体動センサーによるレート応答特性を明らかにすることを目的に、ペースメーカー内蔵rate profile機能およびredraw機能を用い、実験を行なった。健常男子1名を対象に、Intermedics社製DASHを胸壁に絆創膏固定し、(1) 歩行速度2.0mph、3.4mph、傾斜度0%、14%を組合せた各段階3分間のプロトコール、(2) 歩行速度2.0mph、3.4mph、4.2mph、駆け足4.2mphの各段階3分間のプロトコール、(3) 歩数100歩/分での平地歩行、Master 2階段試験各3分間のプロトコールに従い運動負荷試験を実施した。その結果、歩行速度に対する洞調律の増加に対応するようなパラメーター設定では、傾斜度の増加、階段に対しては過小応答、駆け足に対しては過剰応答を示した。以上の結果から、体動センサーの場合、同一のレート応答パラメーター設定では、異なった運動全てに対し生理的に対応することは困難であると考えられた。
AbstractList Non-physiological rate response in the pacemaker using activity sensor assessment by rate profile and redraw function. Rate response in the pacemaker using activity sensor is not uniform in the daily activities. We studied the effects of slope, jogging, stairs on rate response quality of SSIR pacemaker DASH (Intermedics Ltd), using internal rate profile and redraw functions. Exercise tests were performed by three protocols. Protocol (1) includes walk on treadmill with slope of 0% and 14% at 2.0mph and 3.4mph for 3min at each stage of exercise. Protocol (2) includes walk on treadmill with 0% slope at 2.0mph, 3.4mph, 4.2mph and jog at 4.2mph. Protocol (3) includes walk and Master two steps tests with constant speed of 100 steps/min. Sinus rate and activity sensor rate profiles of different settings of rate response parameters were compared. As the result, if rate response parameters were set optimal to walk speed, sensor rate was under-responsive both to slope and stairs, and over responsive to jogging. Thus, one setting of rate response parameters was not optimal to all of daily activities. This is a limitation of rate response quality by activity sensor. 坂道歩行、階段歩行、駆け足に対する体動センサーによるレート応答特性を明らかにすることを目的に、ペースメーカー内蔵rate profile機能およびredraw機能を用い、実験を行なった。健常男子1名を対象に、Intermedics社製DASHを胸壁に絆創膏固定し、(1) 歩行速度2.0mph、3.4mph、傾斜度0%、14%を組合せた各段階3分間のプロトコール、(2) 歩行速度2.0mph、3.4mph、4.2mph、駆け足4.2mphの各段階3分間のプロトコール、(3) 歩数100歩/分での平地歩行、Master 2階段試験各3分間のプロトコールに従い運動負荷試験を実施した。その結果、歩行速度に対する洞調律の増加に対応するようなパラメーター設定では、傾斜度の増加、階段に対しては過小応答、駆け足に対しては過剰応答を示した。以上の結果から、体動センサーの場合、同一のレート応答パラメーター設定では、異なった運動全てに対し生理的に対応することは困難であると考えられた。
Author YAMAMOTO Y
Author_FL 山本 豊
Author_FL_xml – sequence: 1
  fullname: 山本 豊
Author_xml – sequence: 1
  fullname: YAMAMOTO Y
  organization: Department of Cardiology, St. Marianna University School of Medicine Yokohama-shi Seibu Hospital | 聖マリアンナ医科大学横浜市西部病院循環器内科
BackLink https://cir.nii.ac.jp/crid/1390282679930762368$$DView record in CiNii
BookMark eNot0D1PwzAYBGALFYlSujN6YE3wd2w2VEFBqmCBGTn269YltaM4Leq_p6gsd9M9w12jScoJELqlpKaUG3a_LTZT07CaiVpIdYGmVGteKWKaCZoSTkhFNNVXaF5KbInUwnBK5BQd3nKq-s2xxNzldXS2w4MdAQ9Q-pwK4JjwuAHcWwc7-w0D3peY1ti6MR7ieMQFUsnDA7alQCk7SCNuj2ejH3KIHWCb_Mnzg_3BYZ9Ow5xu0GWwXYH5f8_Q5_PTx-KlWr0vXxePq2pLpRir4IIBqlxLvCGeMk9a5QwEJ6wQjqnWc0mN4zIY7YFKLgU0KhALoEXjLZ-hu7ObYvxy8S9PfxGmmWqM4aRRjCvNfwFCLWKl
ContentType Journal Article
DBID RYH
DOI 10.11392/jsao1972.24.456
DatabaseName CiNii Complete
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
DocumentTitleAlternate Rate Profile機能とRedraw機能を用いた検討
体動センサーによるレート応答の非生理性 Rate Profile機能とRedraw機能を用いた検討
DocumentTitle_FL 体動センサーによるレート応答の非生理性 Rate Profile機能とRedraw機能を用いた検討
EISSN 1883-6097
EndPage 461
ExternalDocumentID 10005625060
GroupedDBID 2WC
ALMA_UNASSIGNED_HOLDINGS
JSF
KQ8
RJT
RYH
ID FETCH-LOGICAL-j154t-fcf9e16cb0d90d12d0b6c9efc4a44c26bd3519c35f98de15354e76f0aee847da3
ISSN 0300-0818
IngestDate Thu Jun 26 23:51:32 EDT 2025
IsPeerReviewed false
IsScholarly true
Issue 2
Language Japanese
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-j154t-fcf9e16cb0d90d12d0b6c9efc4a44c26bd3519c35f98de15354e76f0aee847da3
PageCount 6
ParticipantIDs nii_cinii_1390282679930762368
PublicationCentury 1900
PublicationDate 1995
PublicationDateYYYYMMDD 1995-01-01
PublicationDate_xml – year: 1995
  text: 1995
PublicationDecade 1990
PublicationTitle Jinko Zoki
PublicationTitleAlternate Jpn. j. artif. Organs
人工臓器
JJAO
The Japanese Journal of Artificial Organs
PublicationTitle_FL Jpn. j. artif. Organs
人工臓器
JJAO
The Japanese Journal of Artificial Organs
PublicationYear 1995
Publisher 一般社団法人 日本人工臓器学会
JAPANESE SOCIETY FOR ARTIFICIAL ORGANS
Publisher_xml – name: 一般社団法人 日本人工臓器学会
– name: JAPANESE SOCIETY FOR ARTIFICIAL ORGANS
SSID ssib058493105
ssj0066718
ssib002671031
ssib002670267
ssib000940189
ssib005879672
Score 1.409777
Snippet Non-physiological rate response in the pacemaker using activity sensor assessment by rate profile and redraw function. Rate response in the pacemaker using...
SourceID nii
SourceType Publisher
StartPage 456
SubjectTerms activity sensor
daily activity
rate profile
rate responsive pacemaker
redraw function
Title Non-physiological rate response in the pacemaker using activity sensor: assessment by rate profile and redraw function
URI https://cir.nii.ac.jp/crid/1390282679930762368
Volume 24
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bi9QwFA7j-uKLKCreVvJgnkrHXtJcfOuMlUXZXYRZWHyRNElhdtkWZmcU_Uv-SU-StlNdwQsMoZMmYej55uQ76bkg9BIYv-aCUpCAzsBAsSn853QaS5HVRnHJG5-O4fiEHZ3Rd-fF-Wz2feK1tNvWc_3tt3El_yNV6AO5uijZf5DsuCh0wDXIF1qQMLR_JeOTro390cSowVzih2gT_F7t4MMIZrG9Upd2E-38yYCLZfAlI67Bhu18nUg1Juh0fNSv0lfzDg7o1mzUl8htgqMgB0YLxmwXfewu16MCAT1-fLo67VW76WPsilH8pKJkIZyPRQWtIOWSVJyU0FmRqiByQcqcVIwsciILP7iET-S6JIwr_MXST-vvuWmLcAtW5ETmfiFJSuEuyjekZH7wkshyovtyF_AuetVsg24WIo9ZEtx5B-UdArB7kGYTTUwLNtnUacj4fnO_AHroNoxr1bn6a_OMzseJP2Xhdq9BnK2YsOQWup1xnjr_0fcfJlxWgqkqprnb-Fjdq__uSmrslZ_gku2DloEISqDao-3GYLgIr8DCkxjescMvfvXL7wVe1K7XE160uofu9gYNLgM676PZhXqAPt9AJnaYwgMy8brFgEw8IhN7ZOIBmTgg8zXe4xLXX8MaPS4x4BIHXOIBlw_R2dtqtTyK-wof8QVQ923c6EbalOk6MTIxaWaSmmlpG00VpTpjtXH1I3VeNFIYC5tzQS1nTaKsBVZlVP4IHbRdax8jLLnJNPAwkRlGTZIrIWqplCyABcLk5gk6hGf0Sa9dCw_RnTUwDuw8ATqQM_H0D_efoTshm4E7fXuODrabnT0EPrqtX3gc_AAxi3Nz
linkProvider Colorado Alliance of Research Libraries
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Non-physiological+rate+response+in+the+pacemaker+using+activity+sensor%3A+assessment+by+rate+profile+and+redraw+function&rft.jtitle=Jinko+Zoki&rft.au=YAMAMOTO+Y&rft.date=1995&rft.pub=%E4%B8%80%E8%88%AC%E7%A4%BE%E5%9B%A3%E6%B3%95%E4%BA%BA+%E6%97%A5%E6%9C%AC%E4%BA%BA%E5%B7%A5%E8%87%93%E5%99%A8%E5%AD%A6%E4%BC%9A&rft.issn=0300-0818&rft.eissn=1883-6097&rft.volume=24&rft.issue=2&rft.spage=456&rft.epage=461&rft_id=info:doi/10.11392%2Fjsao1972.24.456&rft.externalDocID=10005625060
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0300-0818&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0300-0818&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0300-0818&client=summon