THE USABILITY OF NEW MICRODEBRIDER SYSTEMS (HUMMER 2 & XPS) FOR ESS
Recentry the number of surgeons who use powered instrumentations (microdebrider) for ESS has increased in Japan because the usability and safety of these devices have been recognized. In order to evaluate the new microdebrider systems, i.e., Hummer 2 (Stryker Corp, USA) and XPS (Xomed Corp, USA), we...
Saved in:
Published in | JIBI INKOKA TEMBO Vol. 41; no. 3; pp. 265 - 270 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | Japanese |
Published |
Society of Oto-rhino-laryngology Tokyo
1998
耳鼻咽喉科展望会 |
Subjects | |
Online Access | Get full text |
ISSN | 0386-9687 1883-6429 |
DOI | 10.11453/orltokyo1958.41.265 |
Cover
Abstract | Recentry the number of surgeons who use powered instrumentations (microdebrider) for ESS has increased in Japan because the usability and safety of these devices have been recognized. In order to evaluate the new microdebrider systems, i.e., Hummer 2 (Stryker Corp, USA) and XPS (Xomed Corp, USA), we performed endoscopic sinus surgery for 26 cases with chronic sinuitis using these new devices from November to December 1997, and compared the new microdebrider systems and Hummer system for the usability. As a result, the advantages of these new devices are as follows : 1) There is less plugging of aspiration during operation by using more powerful handpiece and irrigated double cutter blades, 2) these new devices also enables bony dissection, such as the bony partitions in the ethmoid labyrinth and bony borders of the maxillary ostium, and 3) the XPS system can also be used for bone work by using the drill bar. These new devices will be able to dissect the frontal recess and maxillary sinus by using curved blades (Hummer 2 has a 15-degree angle, XPS 40-degree angle), and therefore we will be able to approach almost entire sinuses easier. The new microdebrider systems can overcome the Hummer's weakness almost completely. We require more thicker cutter blades about 5 mm in diameter, because most patients with chronic sinuitis in Japan have more severe polypoid lesion and surgical area which is mostly more expanded than FESS, compared to those in USA and Europe. |
---|---|
AbstractList | Recentry the number of surgeons who use powered instrumentations (microdebrider) for ESS has increased in Japan because the usability and safety of these devices have been recognized. In order to evaluate the new microdebrider systems, i.e., Hummer 2 (Stryker Corp, USA) and XPS (Xomed Corp, USA), we performed endoscopic sinus surgery for 26 cases with chronic sinuitis using these new devices from November to December 1997, and compared the new microdebrider systems and Hummer system for the usability. As a result, the advantages of these new devices are as follows : 1) There is less plugging of aspiration during operation by using more powerful handpiece and irrigated double cutter blades, 2) these new devices also enables bony dissection, such as the bony partitions in the ethmoid labyrinth and bony borders of the maxillary ostium, and 3) the XPS system can also be used for bone work by using the drill bar. These new devices will be able to dissect the frontal recess and maxillary sinus by using curved blades (Hummer 2 has a 15-degree angle, XPS 40-degree angle), and therefore we will be able to approach almost entire sinuses easier. The new microdebrider systems can overcome the Hummer's weakness almost completely. We require more thicker cutter blades about 5 mm in diameter, because most patients with chronic sinuitis in Japan have more severe polypoid lesion and surgical area which is mostly more expanded than FESS, compared to those in USA and Europe. Recentry the number of surgeons who use powered instrumentations (microdebrider) for ESS has increased in Japan because the usability and safety of these devices have been recognized. In order to evaluate the new microdebrider systems, i.e., Hummer 2 (Stryker Corp, USA) and XPS (Xomed Corp, USA), we performed endoscopic sinus surgery for 26 cases with chronic sinuitis using these new devices from November to December 1997, and compared the new microdebrider systems and Hummer system for the usability. As a result, the advantages of these new devices are as follows : 1) There is less plugging of aspiration during operation by using more powerful handpiece and irrigated double cutter blades, 2) these new devices also enables bony dissection, such as the bony partitions in the ethmoid labyrinth and bony borders of the maxillary ostium, and 3) the XPS system can also be used for bone work by using the drill bar. These new devices will be able to dissect the frontal recess and maxillary sinus by using curved blades (Hummer 2 has a 15-degree angle, XPS 40-degree angle), and therefore we will be able to approach almost entire sinuses easier. The new microdebrider systems can overcome the Hummer's weakness almost completely. We require more thicker cutter blades about 5 mm in diameter, because most patients with chronic sinuitis in Japan have more severe polypoid lesion and surgical area which is mostly more expanded than FESS, compared to those in USA and Europe. 内視鏡下鼻内副鼻腔手術用の新しいマイクロデブリッダーシステムの登場が相次いでいる。われわれは1997年11月よりハマー2を, また1997年12月よりXPSを慢性副鼻腔炎患者15例26側に使用して前機種 (ハマー) との比較をし, その有用性の検討を行った。その結果, 新しいマイクロデブリッダーシステムは, ハンドピースやカッターの改良, イリゲーション機能の追加などによって, 最大の欠点であった吸引の詰まりが大幅に改善され, 手術時間が短縮された。また節骨蜂巣の骨性の隔壁も薄ければある程度削除できるようになった。さらに今後は, 欧米ではすでに使用されている弩曲カッターの登場により, 直カッターだけでは難しかった上顎洞やfrontal recessなどの処理もかなり可能になると思われ, ESSにおけるマイクロデブリッダーの適用範囲が拡がって, その有用性がさらに向上するものと思われる。 |
Author | Arai, Motohiro Okamoto, Makito Higuchi, Akihiro Yao, Kazuo Saitou, Masaru |
Author_FL | 八尾 和雄 樋口 彰宏 岡本 牧人 斉藤 大 新井 基洋 |
Author_FL_xml | – sequence: 1 fullname: 樋口 彰宏 – sequence: 2 fullname: 新井 基洋 – sequence: 3 fullname: 斉藤 大 – sequence: 4 fullname: 岡本 牧人 – sequence: 5 fullname: 八尾 和雄 |
Author_xml | – sequence: 1 fullname: Higuchi, Akihiro organization: Department of Otorhinolaryngology, Yokohama Red Cross Hospital – sequence: 1 fullname: Saitou, Masaru organization: Department of Otorhinolaryngology, Yokohama Red Cross Hospital – sequence: 1 fullname: Okamoto, Makito organization: Department of Otorhinolaryngology, Kitasato University School of Medicine – sequence: 1 fullname: Yao, Kazuo organization: Department of Otorhinolaryngology, Kitasato University School of Medicine – sequence: 1 fullname: Arai, Motohiro organization: Department of Otorhinolaryngology, Yokohama Red Cross Hospital |
BackLink | https://cir.nii.ac.jp/crid/1390282679927341056$$DView record in CiNii |
BookMark | eNpNkEtPg0AAhDemJtbaf-BhD8bogbrvx7GlICRFDNBoT2Qpi1IrGOil_15MjfEyk0m-TCZzCUZN21gArjGaYcw4fWi7_aH9OLZYczVjeEYEPwNjrBR1BCN6BMaIKuFooeQFmPZ9XSDEldRCyDFws8CD63S-CFdhtoGxD5-8FxiFbhIvvUUSLr0Epps086IU3gXrKBoygbfw9Tm9h36cQC9Nr8B5Zfa9nf76BKx9L3MDZxU_hu585ewwx8JhValLaaSurDGo4owMGzA1hFOiS05Lja1hBZEMWWtEUViCFVFVZTlV2DA6ATen3qau8239o5hqRBQRUmsiKcOIiwELTtiuP5g3m3919afpjrnpDvV2b_P_f-UM5_Qkw21_yPbddLlt6DetwmJc |
ContentType | Journal Article |
Copyright | Oto-rhino-laryngology Tokyo |
Copyright_xml | – notice: Oto-rhino-laryngology Tokyo |
DBID | RYH |
DOI | 10.11453/orltokyo1958.41.265 |
DatabaseName | CiNii Complete |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
DocumentTitleAlternate | 新マイクロデブリッダーシステム,ハマー2およびXPSの有用性 |
DocumentTitle_FL | 新マイクロデブリッダーシステム,ハマー2およびXPSの有用性 |
EISSN | 1883-6429 |
EndPage | 270 |
ExternalDocumentID | 130003795086 article_orltokyo1958_41_3_41_3_265_article_char_en |
GroupedDBID | ALMA_UNASSIGNED_HOLDINGS JSF RJT OK1 RYH |
ID | FETCH-LOGICAL-j1516-4fd9d7a79feaa0f54279613a25329d53d91ea4b2740eea6bbe21828ffe5381a43 |
ISSN | 0386-9687 |
IngestDate | Fri Jun 27 00:46:25 EDT 2025 Wed Sep 03 06:29:51 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 3 |
Language | Japanese |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-j1516-4fd9d7a79feaa0f54279613a25329d53d91ea4b2740eea6bbe21828ffe5381a43 |
OpenAccessLink | https://www.jstage.jst.go.jp/article/orltokyo1958/41/3/41_3_265/_article/-char/en |
PageCount | 6 |
ParticipantIDs | nii_cinii_1390282679927341056 jstage_primary_article_orltokyo1958_41_3_41_3_265_article_char_en |
PublicationCentury | 1900 |
PublicationDate | 1998 |
PublicationDateYYYYMMDD | 1998-01-01 |
PublicationDate_xml | – year: 1998 text: 1998 |
PublicationDecade | 1990 |
PublicationTitle | JIBI INKOKA TEMBO |
PublicationTitleAlternate | O.R.L.Tokyo |
PublicationTitle_FL | OTO-RHINO-LARYNGOLOGY, TOKYO 耳鼻咽喉科展望 ORL, Tokyo O.R.L.Tokyo OTO-RHINO-LARYNGOLOGY,TOKYO 耳展 |
PublicationYear | 1998 |
Publisher | Society of Oto-rhino-laryngology Tokyo 耳鼻咽喉科展望会 |
Publisher_xml | – name: Society of Oto-rhino-laryngology Tokyo – name: 耳鼻咽喉科展望会 |
References | 4) Dewey AC, Jhon HK : Powerd instrumentation in dissection of frontal recess. ENT Journal 75 : 359-363, 1996. 1) Setliff RC, Parsons DS : The “Hummer” : New instrumentation for functional endoscopic sinus surgery. Am J Rhinology 8 : 275-278, 1994. 2) Chiristmas DA, Krouse JH : Powerd instrumentation in functional endoscopic sinus surgery 1 : Surgical technique. ENT Journal 75 : 33-40, 1996. 11) 森山寛 : 内視鏡下鼻内副鼻腔手術-進歩と定着-.耳喉頭頸68 : 287-298, 1996. 5) John HK, Dewey AC : Powered Endoscopic Sinus Surgery. Williams & Willkins A Waverly Company, 1997. 13) Charles WG, William EG, Daniel GB : Modified transnasal endoscopic Lothrop procedure Frontal drillout. Oper Tech Otolaryngol Head Neck Surg 6 : 193-200, 1997. 8) Kennedy DW, Zinreich SJ, Rosenbaum A, et al : Functional endoscopic sinus surgery. Theory and diagnosis. Arch Otolaryngol 111 : 576-582, 1985. 9) 大西俊郎, 小澤仁, 笠原行喜, 他 : 内視鏡的副鼻腔手術.メジカルビュー社, 1995. 6) 藤谷哲, 洲崎春海, 野村恭也, 他 : ハマーIIマイクロデブリッダーシステムの有用性に関する検討耳展39 : 661-665, 1996. 12) 大西俊郎, 橘敏郎, 佐藤英明, 他 : 内視鏡的副鼻腔手術 (ESS) における上顎一前頭法.耳展39 : 653-660, 1996. 10) 足川力雄, 森山寛, 内田豊, 他 : 内視鏡下鼻内手術.医学書院, 1995. 7) 樋口彰宏, 新井基洋, 斉藤大, 他 : 整形外科関節手術用シェーバーシステム (SE5, ペースセッター) のESSへの使用の有用性.耳展40 : 438-443, 1997. 3) John HK, Dewey AC : Powered instrumentation in functional endoscopic sinus surgery 2. A comparative study. ENT Journal 75 : 42-44, 1996. |
References_xml | – reference: 10) 足川力雄, 森山寛, 内田豊, 他 : 内視鏡下鼻内手術.医学書院, 1995. – reference: 5) John HK, Dewey AC : Powered Endoscopic Sinus Surgery. Williams & Willkins A Waverly Company, 1997. – reference: 13) Charles WG, William EG, Daniel GB : Modified transnasal endoscopic Lothrop procedure Frontal drillout. Oper Tech Otolaryngol Head Neck Surg 6 : 193-200, 1997. – reference: 7) 樋口彰宏, 新井基洋, 斉藤大, 他 : 整形外科関節手術用シェーバーシステム (SE5, ペースセッター) のESSへの使用の有用性.耳展40 : 438-443, 1997. – reference: 8) Kennedy DW, Zinreich SJ, Rosenbaum A, et al : Functional endoscopic sinus surgery. Theory and diagnosis. Arch Otolaryngol 111 : 576-582, 1985. – reference: 3) John HK, Dewey AC : Powered instrumentation in functional endoscopic sinus surgery 2. A comparative study. ENT Journal 75 : 42-44, 1996. – reference: 9) 大西俊郎, 小澤仁, 笠原行喜, 他 : 内視鏡的副鼻腔手術.メジカルビュー社, 1995. – reference: 1) Setliff RC, Parsons DS : The “Hummer” : New instrumentation for functional endoscopic sinus surgery. Am J Rhinology 8 : 275-278, 1994. – reference: 2) Chiristmas DA, Krouse JH : Powerd instrumentation in functional endoscopic sinus surgery 1 : Surgical technique. ENT Journal 75 : 33-40, 1996. – reference: 6) 藤谷哲, 洲崎春海, 野村恭也, 他 : ハマーIIマイクロデブリッダーシステムの有用性に関する検討耳展39 : 661-665, 1996. – reference: 11) 森山寛 : 内視鏡下鼻内副鼻腔手術-進歩と定着-.耳喉頭頸68 : 287-298, 1996. – reference: 12) 大西俊郎, 橘敏郎, 佐藤英明, 他 : 内視鏡的副鼻腔手術 (ESS) における上顎一前頭法.耳展39 : 653-660, 1996. – reference: 4) Dewey AC, Jhon HK : Powerd instrumentation in dissection of frontal recess. ENT Journal 75 : 359-363, 1996. |
SSID | ssib005879667 ssib005902162 ssib005879668 ssib058493089 ssib029852170 ssj0066717 ssib007484760 ssib002004161 |
Score | 1.466402 |
Snippet | Recentry the number of surgeons who use powered instrumentations (microdebrider) for ESS has increased in Japan because the usability and safety of these... |
SourceID | nii jstage |
SourceType | Publisher |
StartPage | 265 |
SubjectTerms | chronic sinuitis endoscopic sinus surgery Hummer 2 XPS microdebrider XPS ハマー2 マイクロデブリッダー 内視鏡下鼻内副鼻腔手術 |
Title | THE USABILITY OF NEW MICRODEBRIDER SYSTEMS (HUMMER 2 & XPS) FOR ESS |
URI | https://www.jstage.jst.go.jp/article/orltokyo1958/41/3/41_3_265/_article/-char/en https://cir.nii.ac.jp/crid/1390282679927341056 |
Volume | 41 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
ispartofPNX | JIBI INKOKA TEMBO, 1998/06/15, Vol.41(3), pp.265-270 |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3fb9MwELbYeOEFgQAxYMgPCIGqjCR24vixm4ZWqq2gtVLfokvisLTQoJA-jL-euzptPJjEjxerddoo9n09313vvmPsFQQ5yEILr1AROiihb7wkgsJTEECWG6mUTZC9iM9m8sM8mvcx3U11SZsd5T9urSv5H6niHMqVqmT_QbK7m-IEvkb54ogSxvGvZTyzHLk2sYKyFc8pxa4wVIllmi0jORmSKLmvOBNupD3_eEkBAUoy3Ipga6KOjkeD0cV4Mh4OpqfnxxMnOk2dUwbDZXVVNXUPFahQNbS1O3kJqCnWg3P4Ds16F8hdAgKjxtklXu3jDVSA10cauzRSXM2krb3mqlrVHrrf16vPli5qWi-va0d_iST2dNydp8bq1yQRHro82lXAlvmqA5pwtaltI9EdzKHtMPK7zpebzh1186WlByD2nCOJrv_2yzfYtOnfO18o6n0b77G7oVIBJYKOPzlOF3GQOdW-UaLQJ1S_vHdI0DTaSQ7pIrGzqt7pDHWCJlKvFdHi08Injn9rL-CtN32hd9vVFXjSst7dsig0lRboOBAjxN6qqhxraPqA3e_cGD60mHzI7izgETtBPPIdHnldcsQjv4FH3uGRv7Fo5CF_zRGLbzkikSMSH7PZ-9PpyZnXNenwFmgsxp4sC10oULo0AH4ZyRB3JxAQRiLURSQKHRiQWaikbwzEWWaoZ0BSlgaP2gCkeML2V_XKPGU8KwIo_bz0Sy1klIeQ5CVa5z4EFHaQcMCGduXpN8vEkna_vNTdplQGqbAD7tbuI1TEiDrjgB3ipqV5RSN6PxRyiJXWxPKErkb87A_Xn7N7tiqVgnAv2H7brM0hmqVt9nKDop8fIn0H |
linkProvider | Colorado Alliance of Research Libraries |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=The+Usability+of+New+Microdebrider+Systems+%28Hummer+2+%26+XPS%29+for+ESS&rft.jtitle=JIBI+INKOKA+TEMBO&rft.au=Higuchi+Akihiro&rft.au=Arai+Motohiro&rft.au=Saitou+Masaru&rft.au=Okamoto+Makito&rft.date=1998&rft.pub=Society+of+Oto-rhino-laryngology+Tokyo&rft.issn=0386-9687&rft.eissn=1883-6429&rft.volume=41&rft.issue=3&rft.spage=265&rft.epage=270&rft_id=info:doi/10.11453%2Forltokyo1958.41.265&rft.externalDocID=130003795086 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0386-9687&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0386-9687&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0386-9687&client=summon |