Real-time information presentation system for support during breast reconstruction

Reduction of the moldability of the postoperative breast shape during breast reconstruction has been cited as an issue. We have developed a system that obtains three-dimensional shape difference information before mastectomy and during reconstruction, and maps the local shape difference information...

Full description

Saved in:
Bibliographic Details
Published inTransactions of Japanese Society for Medical and Biological Engineering Vol. Annual58; no. Abstract; p. 260
Main Authors Washio, Toshikatsu, Kaneko, Kotaro, Chiba, Shinji, Yano, Tomoyuki, Suzuki, Takashi, Arafune, Tatsuhiko
Format Journal Article
LanguageJapanese
Published Japanese Society for Medical and Biological Engineering 2020
公益社団法人 日本生体医工学会
Online AccessGet full text
ISSN1347-443X
1881-4379
DOI10.11239/jsmbe.Annual58.260

Cover

Abstract Reduction of the moldability of the postoperative breast shape during breast reconstruction has been cited as an issue. We have developed a system that obtains three-dimensional shape difference information before mastectomy and during reconstruction, and maps the local shape difference information to the patient's skin superficial. The system evaluation by a plastic surgeon using this system revealed that it was desirable to be able to grasp shape information more quickly. Therefore, the purpose of this study was to develop a system that calculates the shape difference information in real time based on the left and right breast shapes. As a system evaluation, the shape difference during reconstruction was reproduced using a mannequin simulating a patient, and measurement and projection experiments were performed. It is now possible to project the shape difference information onto the skin surface without the process of pasting the shape difference texture onto the three-dimensional shape data.
AbstractList Reduction of the moldability of the postoperative breast shape during breast reconstruction has been cited as an issue. We have developed a system that obtains three-dimensional shape difference information before mastectomy and during reconstruction, and maps the local shape difference information to the patient's skin superficial. The system evaluation by a plastic surgeon using this system revealed that it was desirable to be able to grasp shape information more quickly. Therefore, the purpose of this study was to develop a system that calculates the shape difference information in real time based on the left and right breast shapes. As a system evaluation, the shape difference during reconstruction was reproduced using a mannequin simulating a patient, and measurement and projection experiments were performed. It is now possible to project the shape difference information onto the skin surface without the process of pasting the shape difference texture onto the three-dimensional shape data.
Reduction of the moldability of the postoperative breast shape during breast reconstruction has been cited as an issue. We have developed a system that obtains three-dimensional shape difference information before mastectomy and during reconstruction, and maps the local shape difference information to the patient's skin superficial. The system evaluation by a plastic surgeon using this system revealed that it was desirable to be able to grasp shape information more quickly. Therefore, the purpose of this study was to develop a system that calculates the shape difference information in real time based on the left and right breast shapes. As a system evaluation, the shape difference during reconstruction was reproduced using a mannequin simulating a patient, and measurement and projection experiments were performed. It is now possible to project the shape difference information onto the skin surface without the process of pasting the shape difference texture onto the three-dimensional shape data. 乳房再建における乳房形状の定量的な評価指標は未だ確立されておらず,それに伴う術後乳房形状の整容性低下が課題として挙げられている.我々は乳腺切除前と再建術中の三次元形状差分情報を求め,局所の形状差情報を患者の皮膚表在へプロジェクションマッピングするシステムを開発し既報にて報告した.本システムを用いた形成外科専門医によるシステム評価により,計算処理が煩雑であること,形状情報がより迅速に把握できることが望ましいなどの課題が明らかとなった.そこで本研究では術前ではなく左右の対側の乳房形状を基準に,形状差情報をリアルタイムに計算してプロジェクションマッピングに反映させる高速投影システムを開発することを目的とした.KinectV2にて計測できる3次元形状情報のうち従来使用したSTLではなく2次元の深度画像であるDepth Mapを利用し,特定のフレームで計測したDepth Mapと現在のDepth Mapの輝度値差分を導出し,プロジェクションマッピングすることとした.システム評価として,まず患者を模擬したマネキン上半身を手術ベッドに設置し,乳房部分を取り外して再建中の形状差を再現し,システムを適用して計測と投影実験を行った.プロジェクタの投影方向に制限は生じるが,従来必要だった三次元形状データ上への形状差分テクスチャ貼り付け工程無しに,形状差情報を皮膚表在へ投影が可能となったので報告する.
Author Arafune, Tatsuhiko
Washio, Toshikatsu
Yano, Tomoyuki
Kaneko, Kotaro
Suzuki, Takashi
Chiba, Shinji
Author_FL 荒船 龍彦
鈴木 孝司
鷲尾 利克
金子 晃太郎
千葉 慎二
矢野 智之
Author_FL_xml – sequence: 1
  fullname: 金子 晃太郎
– sequence: 2
  fullname: 鈴木 孝司
– sequence: 3
  fullname: 千葉 慎二
– sequence: 4
  fullname: 鷲尾 利克
– sequence: 5
  fullname: 矢野 智之
– sequence: 6
  fullname: 荒船 龍彦
Author_xml – sequence: 1
  fullname: Washio, Toshikatsu
  organization: National Institute of Advanced Industrial Science and Technology
– sequence: 1
  fullname: Kaneko, Kotaro
  organization: Faculty of Science and Technology, Department of Science and Engineering, Tokyo Denki University, Japan
– sequence: 1
  fullname: Chiba, Shinji
  organization: Microsoft Japan, Co., Ltd
– sequence: 1
  fullname: Yano, Tomoyuki
  organization: Cancer Institute Hospital
– sequence: 1
  fullname: Suzuki, Takashi
  organization: Tokyo Womens Medical University
– sequence: 1
  fullname: Arafune, Tatsuhiko
  organization: Faculty of Science and Technology, Department of Science and Engineering, Tokyo Denki University, Japan
BackLink https://cir.nii.ac.jp/crid/1390848250134354816$$DView record in CiNii
BookMark eNpFkMtqwzAQRUVJoWmaL-jGi26djizJkpch9AWBQmihOyM7o1TBlo2kLPL3VZo-NvO4c2Zg7jWZuMEhIbcUFpQWrLrfh77BxdK5g-6EWhQlXJApVYrmnMlqkmrGZc45-7gi8xBsA0ApABRiSjYb1F0ebY-ZdWbwvY52cNnoMaCL5yYcQ8Q-S9MsHMZx8DHbHrx1u6zxqEPMPLaDC9Ef2hN_Qy6N7gLOf_KMvD8-vK2e8_Xr08tquc73FHiZl0oaabTSkm9NgxS04JVOSTMQQA012ADbgiiRak5BSSFlVUCVdFMxwWbk7nzXWVu39hQpq0BxVaR9xpngipYJ25yxfYh6h_Xoba_9sdY-2rbD-tu9-te9etmkR3Qb_5Xk5x_cfmpfo2NfVpB1eg
ContentType Journal Article
Copyright 2020 Japanese Society for Medical and Biological Engineering
Copyright_xml – notice: 2020 Japanese Society for Medical and Biological Engineering
DBID RYH
DOI 10.11239/jsmbe.Annual58.260
DatabaseName CiNii Complete
DatabaseTitleList

DeliveryMethod fulltext_linktorsrc
Discipline Engineering
DocumentTitleAlternate 乳房再建術中支援のためのリアルタイム情報提示システム
DocumentTitle_FL 乳房再建術中支援のためのリアルタイム情報提示システム
EISSN 1881-4379
EndPage 260
ExternalDocumentID 130007884980
article_jsmbe_Annual58_Abstract_Annual58_260_article_char_en
GroupedDBID 2WC
ALMA_UNASSIGNED_HOLDINGS
JSF
OK1
RJT
RYH
ID FETCH-LOGICAL-j1046-687f7fa8a74dfbe10a549a10aa30501f1feb03d056e1a410875779209febf9353
ISSN 1347-443X
IngestDate Thu Jun 26 22:50:26 EDT 2025
Wed Sep 03 06:13:22 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue Abstract
Language Japanese
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-j1046-687f7fa8a74dfbe10a549a10aa30501f1feb03d056e1a410875779209febf9353
OpenAccessLink https://www.jstage.jst.go.jp/article/jsmbe/Annual58/Abstract/Annual58_260/_article/-char/en
PageCount 1
ParticipantIDs nii_cinii_1390848250134354816
jstage_primary_article_jsmbe_Annual58_Abstract_Annual58_260_article_char_en
PublicationCentury 2000
PublicationDate 2020
PublicationDateYYYYMMDD 2020-01-01
PublicationDate_xml – year: 2020
  text: 2020
PublicationDecade 2020
PublicationTitle Transactions of Japanese Society for Medical and Biological Engineering
PublicationTitleAlternate Transactions of Japanese Society for Medical and Biological Engineering
PublicationTitle_FL TJSBME
Trans. jpn. Soc. Med. Bio. Eng
生体医工学
Transactions of Japanese Society for Medical and Biological Engineering
PublicationYear 2020
Publisher Japanese Society for Medical and Biological Engineering
公益社団法人 日本生体医工学会
Publisher_xml – name: Japanese Society for Medical and Biological Engineering
– name: 公益社団法人 日本生体医工学会
SSID ssib001100025
ssib002484549
ssib023159591
ssj0069534
ssib020474828
ssib000937326
ssib058494337
ssib002223871
ssib046007037
ssib007484362
Score 2.1825347
Snippet Reduction of the moldability of the postoperative breast shape during breast reconstruction has been cited as an issue. We have developed a system that obtains...
SourceID nii
jstage
SourceType Publisher
StartPage 260
Title Real-time information presentation system for support during breast reconstruction
URI https://www.jstage.jst.go.jp/article/jsmbe/Annual58/Abstract/Annual58_260/_article/-char/en
https://cir.nii.ac.jp/crid/1390848250134354816
Volume Annual58
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
ispartofPNX Transactions of Japanese Society for Medical and Biological Engineering, 2020, Vol.Annual58(Abstract), pp.260-260
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb5wwELY26aU9VH2qaZqKQ2-IrQED9jGqWkVZtVJTIuWGbB4quwqsGvaSf9l_lBlssFep1NcFFu-CFo9n_I09Mx8h75qyUlUTVQFV4zYjFYGsqAoSTJJUIQDUBrORP39Jzy7Z-VVytVj8dKKWdoNalre_zCv5F6lCG8gVs2T_QrLzQ6EBPoN84QgShuMfyfgCUF6A7PC-qX86CnNrM4o6U6l5DCa82W0RbE-ZiQrD0Qd_9IjnKrIuVs0tlfgY73EO8yryVe5Fek4bPbj-rnktx0unzOFs0uHmTe-v-kH-6O1e1O1u0_q53CCpk401aJX0v31vu_XcNrI-9X7ew2kjB83XMq1XRNTOIv_xL7VxjlkWMDbyB8Pcpds4Bx841oQ0k0XX1AQJd8bvqcKVo3JwbbUmMjDTvrm6P6NEMVZkXd9cq3opzYOX8717pbpxaxAgF2eC0wPyIMqyEKNMV18dxAtw0EXMWLHP3ehFuMYzN9WYM3cjFku_xrbCY0QZtFgPEtB6IpyKhAzpB6hFoAA3BYvtmkQqEh14MXWtKcyFb_3-_jsDTFuD04LVKA66tnWQWP6EPDYulHeq9eEpWazlM_LIkeVzcjFrhudohudqhqc1w4NvPaMZntYMT2uGt68ZL8jlp4_5h7PAsIcEa4xbCFKeNVkjucxY1ag6pBL6UcJJwhRHwyZsakXjChyAOpRgpJDZIRMRFdDeiDiJX5LDru_qV8SrRFmKEnwnGYVMqVLytOI1U7IWKSBycURWuluKrS4RUxiTUIxdWEzjsZhGoW2BTp1_jHmWYNaOyAn0bVG2eAQHDRkvwFEBEcUJ42H6-jffH5OHqHd6nfANOYR-qk8AOQ_q7TgW7wCAn8Hm
linkProvider Colorado Alliance of Research Libraries
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Real-time+information+presentation+system+for+support+during+breast+reconstruction&rft.jtitle=Transactions+of+Japanese+Society+for+Medical+and+Biological+Engineering&rft.au=Kaneko+Kotaro&rft.au=Suzuki+Takashi&rft.au=Chiba+Shinji&rft.au=Washio+Toshikatsu&rft.date=2020&rft.pub=Japanese+Society+for+Medical+and+Biological+Engineering&rft.issn=1347-443X&rft.eissn=1881-4379&rft.volume=Annual58&rft.issue=Abstract&rft.spage=260&rft.epage=260&rft_id=info:doi/10.11239%2Fjsmbe.annual58.260&rft.externalDocID=130007884980
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1347-443X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1347-443X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1347-443X&client=summon