Heart Rate Measuring System using Accelerometer And Gyroscope Sensor in Android Smartphone

Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of heart rate measurement continues to grow, utilizing accelerometer and gyroscope sensors as well as techniques such as R peak detection, digi...

Full description

Saved in:
Bibliographic Details
Published in2024 4th International Conference of Science and Information Technology in Smart Administration (ICSINTESA) pp. 690 - 695
Main Authors Williamsyah, Baginda Mi'Raj, Rizal, Achmad, Wijaya, Rifki, Ziani, Said
Format Conference Proceeding
LanguageEnglish
Published IEEE 12.07.2024
Subjects
Online AccessGet full text
DOI10.1109/ICSINTESA62455.2024.10748185

Cover

Loading…
Abstract Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of heart rate measurement continues to grow, utilizing accelerometer and gyroscope sensors as well as techniques such as R peak detection, digital bandpass, and peak detection. However, previous research was hampered by the smartphone API's 100 Hz measurement frequency limit, so the sensitivity and accuracy of measurements were limited. This research aims to develop a measurement method for a more accurate heart rate using an Android smartphone with a measurement frequency of up to 200 Hz. The method used is Seismocardiography (SCG) with Aortic Open (AO) peak detection on accelerometer and gyroscope sensors. Heart rate data was collected from 20 healthy subjects using a Samsung A50 smartphone and Sensor Logger software and then processed using MATLAB R2015a to extract heart rate information. The SCG signal was processed with a bandpass filter and Hilbert transforms to obtain the envelope of the heart rate signal. The Aortic Open (AO) peak detection determines the heartbeat time. The SCG signal is processed with Baseline Wander Removal, Savitzky-Golay Filter, and Hilbert Transform to obtain the envelope of the heartbeat signal. The Aortic Open (AO) peak detection determines the heartbeat time estimation. The results showed that the SCG signal extraction method and Aortic Open (AO) peak detection achieved an accuracy of 99.3% for placement in the Upper abdomen and 97.36% for placement in the Sternum. This research provides a solution for more accurate and accessible heart rate measurement by utilizing existing smartphone technology.
AbstractList Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of heart rate measurement continues to grow, utilizing accelerometer and gyroscope sensors as well as techniques such as R peak detection, digital bandpass, and peak detection. However, previous research was hampered by the smartphone API's 100 Hz measurement frequency limit, so the sensitivity and accuracy of measurements were limited. This research aims to develop a measurement method for a more accurate heart rate using an Android smartphone with a measurement frequency of up to 200 Hz. The method used is Seismocardiography (SCG) with Aortic Open (AO) peak detection on accelerometer and gyroscope sensors. Heart rate data was collected from 20 healthy subjects using a Samsung A50 smartphone and Sensor Logger software and then processed using MATLAB R2015a to extract heart rate information. The SCG signal was processed with a bandpass filter and Hilbert transforms to obtain the envelope of the heart rate signal. The Aortic Open (AO) peak detection determines the heartbeat time. The SCG signal is processed with Baseline Wander Removal, Savitzky-Golay Filter, and Hilbert Transform to obtain the envelope of the heartbeat signal. The Aortic Open (AO) peak detection determines the heartbeat time estimation. The results showed that the SCG signal extraction method and Aortic Open (AO) peak detection achieved an accuracy of 99.3% for placement in the Upper abdomen and 97.36% for placement in the Sternum. This research provides a solution for more accurate and accessible heart rate measurement by utilizing existing smartphone technology.
Author Ziani, Said
Rizal, Achmad
Wijaya, Rifki
Williamsyah, Baginda Mi'Raj
Author_xml – sequence: 1
  givenname: Baginda Mi'Raj
  surname: Williamsyah
  fullname: Williamsyah, Baginda Mi'Raj
  email: bagindawilliam@student.telkomuniversity.ac.id
  organization: Telkom University,School of Electrical Engineering,Bandung,Indonesia
– sequence: 2
  givenname: Achmad
  surname: Rizal
  fullname: Rizal, Achmad
  email: achmadrizal@telkomuniversity.ac.id
  organization: Telkom University,School of Electrical Engineering,Bandung,Indonesia
– sequence: 3
  givenname: Rifki
  surname: Wijaya
  fullname: Wijaya, Rifki
  email: rifkiwijaya@telkomuniversity.ac.id
  organization: Telkom University,School of Electrical Engineering,Bandung,Indonesia
– sequence: 4
  givenname: Said
  surname: Ziani
  fullname: Ziani, Said
  email: s.ziani@um5r.ac.ma
  organization: Mohammed V University,ENSAM,Rabat,Morocco
BookMark eNo1jz1PwzAYhI0EA5T-AwYPrCl-44_YYxSVNlIBiWRiqZz4DURqPmSnQ_49qSjT6U6n03MP5LYfeiTkGdgGgJmXPCvy93JbpCoWUm5iFosNsERo0PKGrE1iNJeMJwoA7snXHq2f6KedkL6hDWff9t-0mMOEHT2Hi0nrGk_ohw4n9DTtHd3Nfgj1MCItsA-Dp21_yf3QOlp0y974szA9krvGngKur7oi5eu2zPbR4WOXZ-khag1MkXSxZY3jouKKWwbaMqMNY7LRsRNWLXkDoBhz1dJLRCKUTZwztYIGK1HzFXn6m20R8Tj6dgGYj_-P-S_GdFLA
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ICSINTESA62455.2024.10748185
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE/IET Electronic Library (IEL) (UW System Shared)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9798350376111
EndPage 695
ExternalDocumentID 10748185
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i91t-5d2a0fd34b363a018a0989005f82d4a64b3f11600dba0f74746a7dd9c61feb4c3
IEDL.DBID RIE
IngestDate Wed Nov 20 06:17:44 EST 2024
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i91t-5d2a0fd34b363a018a0989005f82d4a64b3f11600dba0f74746a7dd9c61feb4c3
PageCount 6
ParticipantIDs ieee_primary_10748185
PublicationCentury 2000
PublicationDate 2024-July-12
PublicationDateYYYYMMDD 2024-07-12
PublicationDate_xml – month: 07
  year: 2024
  text: 2024-July-12
  day: 12
PublicationDecade 2020
PublicationTitle 2024 4th International Conference of Science and Information Technology in Smart Administration (ICSINTESA)
PublicationTitleAbbrev ICSINTESA
PublicationYear 2024
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.8787163
Snippet Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of...
SourceID ieee
SourceType Publisher
StartPage 690
SubjectTerms Accelerometer
Accelerometers
Accuracy
Android Smartphone
Frequency measurement
Gyroscope
Gyroscopes
Heart beat
Heart Rate
Heart rate measurement
Seismic measurements
Seismocardiography
Sensors
Sternum
Transforms
Title Heart Rate Measuring System using Accelerometer And Gyroscope Sensor in Android Smartphone
URI https://ieeexplore.ieee.org/document/10748185
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwEA-6B_FJxYnf5GGv6Zo2zdLHMZxT2BA7YfgymlwiQ2zH6B70r_fSboqC4Fu55qNcEn5317tfCOnYXIHlUjKrIGTChYopFzqmIuxgoecS7QP644kcPYn7WTLbFKvXtTDW2jr5zAb-sf6XD6VZ-1BZ1ycPeoDZJbu4z5pirT3S2fBmdu8GmeeRzfoyEkmCvl8kgm2XH5en1NgxPCCT7axNyshrsK50YD5-ETL--7MOSfu7TI8-fAHQEdmxxTF5HuHeregj2pB0XAcA8R1tiMmpz3J_oX1jEGw8TwEqlfYLoLfvntSyXFqaoVtbruii8PJVuQCaveF4PoPdtsl0eDMdjNjmAgW2SHnFEojy0EEsdCzjPOQqD1OV4rFzKgKRS5Q7ztHiAY3t0K8QMu8BpEZyZ7Uw8QlpFTj6KaGIbzYULo0gN0JqbA-ApoNBY5CnQogz0vZ6mS8bioz5ViXnf8gvyL5fHh8k5dElaVWrtb1CdK_0db2qnyFkpuE
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwEA86QX1SceK3edhru6ZNs_RxDGfVbYidMHwZbS6RIbZjdA_613tpN0VB8K1c81EuDb-7y90vhLR0KkEzIRwtwXO48aQjjWcc6WMHDR0TZjagPxyJ-InfTcLJqli9qoXRWlfJZ9q1j9VZPhRqaUNlbZs8aAFmk2wh8POwLtfaJq0Vc2b7tpdYJtmkK3wehuj9-dxdd_pxfUqFHv09MlrPWyeNvLrLMnPVxy9Kxn9_2D5pfhfq0YcvCDogGzo_JM8x_r0lfUQrkg6rECC-ozU1ObV57i-0qxTCjWUqQLXSbg705t3SWhZzTRN0bIsFneVWvihmQJM3HM_msOsmGfevx73YWV2h4MwiVjoh-KlnIOBZIILUYzL1IhnhxjPSB54KlBvG0OaBDNuhZ8FF2gGIlGBGZ1wFR6SR4-jHhCLCaY-byIdUcZFhewA0HhSagyzinJ-QptXLdF6TZEzXKjn9Q35FduLxcDAd3I7uz8iuXSobMmX-OWmUi6W-QKwvs8tqhT8BDa6qLg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2024+4th+International+Conference+of+Science+and+Information+Technology+in+Smart+Administration+%28ICSINTESA%29&rft.atitle=Heart+Rate+Measuring+System+using+Accelerometer+And+Gyroscope+Sensor+in+Android+Smartphone&rft.au=Williamsyah%2C+Baginda+Mi%27Raj&rft.au=Rizal%2C+Achmad&rft.au=Wijaya%2C+Rifki&rft.au=Ziani%2C+Said&rft.date=2024-07-12&rft.pub=IEEE&rft.spage=690&rft.epage=695&rft_id=info:doi/10.1109%2FICSINTESA62455.2024.10748185&rft.externalDocID=10748185