Heart Rate Measuring System using Accelerometer And Gyroscope Sensor in Android Smartphone
Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of heart rate measurement continues to grow, utilizing accelerometer and gyroscope sensors as well as techniques such as R peak detection, digi...
Saved in:
Published in | 2024 4th International Conference of Science and Information Technology in Smart Administration (ICSINTESA) pp. 690 - 695 |
---|---|
Main Authors | , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
12.07.2024
|
Subjects | |
Online Access | Get full text |
DOI | 10.1109/ICSINTESA62455.2024.10748185 |
Cover
Loading…
Abstract | Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of heart rate measurement continues to grow, utilizing accelerometer and gyroscope sensors as well as techniques such as R peak detection, digital bandpass, and peak detection. However, previous research was hampered by the smartphone API's 100 Hz measurement frequency limit, so the sensitivity and accuracy of measurements were limited. This research aims to develop a measurement method for a more accurate heart rate using an Android smartphone with a measurement frequency of up to 200 Hz. The method used is Seismocardiography (SCG) with Aortic Open (AO) peak detection on accelerometer and gyroscope sensors. Heart rate data was collected from 20 healthy subjects using a Samsung A50 smartphone and Sensor Logger software and then processed using MATLAB R2015a to extract heart rate information. The SCG signal was processed with a bandpass filter and Hilbert transforms to obtain the envelope of the heart rate signal. The Aortic Open (AO) peak detection determines the heartbeat time. The SCG signal is processed with Baseline Wander Removal, Savitzky-Golay Filter, and Hilbert Transform to obtain the envelope of the heartbeat signal. The Aortic Open (AO) peak detection determines the heartbeat time estimation. The results showed that the SCG signal extraction method and Aortic Open (AO) peak detection achieved an accuracy of 99.3% for placement in the Upper abdomen and 97.36% for placement in the Sternum. This research provides a solution for more accurate and accessible heart rate measurement by utilizing existing smartphone technology. |
---|---|
AbstractList | Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of heart rate measurement continues to grow, utilizing accelerometer and gyroscope sensors as well as techniques such as R peak detection, digital bandpass, and peak detection. However, previous research was hampered by the smartphone API's 100 Hz measurement frequency limit, so the sensitivity and accuracy of measurements were limited. This research aims to develop a measurement method for a more accurate heart rate using an Android smartphone with a measurement frequency of up to 200 Hz. The method used is Seismocardiography (SCG) with Aortic Open (AO) peak detection on accelerometer and gyroscope sensors. Heart rate data was collected from 20 healthy subjects using a Samsung A50 smartphone and Sensor Logger software and then processed using MATLAB R2015a to extract heart rate information. The SCG signal was processed with a bandpass filter and Hilbert transforms to obtain the envelope of the heart rate signal. The Aortic Open (AO) peak detection determines the heartbeat time. The SCG signal is processed with Baseline Wander Removal, Savitzky-Golay Filter, and Hilbert Transform to obtain the envelope of the heartbeat signal. The Aortic Open (AO) peak detection determines the heartbeat time estimation. The results showed that the SCG signal extraction method and Aortic Open (AO) peak detection achieved an accuracy of 99.3% for placement in the Upper abdomen and 97.36% for placement in the Sternum. This research provides a solution for more accurate and accessible heart rate measurement by utilizing existing smartphone technology. |
Author | Ziani, Said Rizal, Achmad Wijaya, Rifki Williamsyah, Baginda Mi'Raj |
Author_xml | – sequence: 1 givenname: Baginda Mi'Raj surname: Williamsyah fullname: Williamsyah, Baginda Mi'Raj email: bagindawilliam@student.telkomuniversity.ac.id organization: Telkom University,School of Electrical Engineering,Bandung,Indonesia – sequence: 2 givenname: Achmad surname: Rizal fullname: Rizal, Achmad email: achmadrizal@telkomuniversity.ac.id organization: Telkom University,School of Electrical Engineering,Bandung,Indonesia – sequence: 3 givenname: Rifki surname: Wijaya fullname: Wijaya, Rifki email: rifkiwijaya@telkomuniversity.ac.id organization: Telkom University,School of Electrical Engineering,Bandung,Indonesia – sequence: 4 givenname: Said surname: Ziani fullname: Ziani, Said email: s.ziani@um5r.ac.ma organization: Mohammed V University,ENSAM,Rabat,Morocco |
BookMark | eNo1jz1PwzAYhI0EA5T-AwYPrCl-44_YYxSVNlIBiWRiqZz4DURqPmSnQ_49qSjT6U6n03MP5LYfeiTkGdgGgJmXPCvy93JbpCoWUm5iFosNsERo0PKGrE1iNJeMJwoA7snXHq2f6KedkL6hDWff9t-0mMOEHT2Hi0nrGk_ohw4n9DTtHd3Nfgj1MCItsA-Dp21_yf3QOlp0y974szA9krvGngKur7oi5eu2zPbR4WOXZ-khag1MkXSxZY3jouKKWwbaMqMNY7LRsRNWLXkDoBhz1dJLRCKUTZwztYIGK1HzFXn6m20R8Tj6dgGYj_-P-S_GdFLA |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/ICSINTESA62455.2024.10748185 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE/IET Electronic Library (IEL) (UW System Shared) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 9798350376111 |
EndPage | 695 |
ExternalDocumentID | 10748185 |
Genre | orig-research |
GroupedDBID | 6IE 6IL CBEJK RIE RIL |
ID | FETCH-LOGICAL-i91t-5d2a0fd34b363a018a0989005f82d4a64b3f11600dba0f74746a7dd9c61feb4c3 |
IEDL.DBID | RIE |
IngestDate | Wed Nov 20 06:17:44 EST 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i91t-5d2a0fd34b363a018a0989005f82d4a64b3f11600dba0f74746a7dd9c61feb4c3 |
PageCount | 6 |
ParticipantIDs | ieee_primary_10748185 |
PublicationCentury | 2000 |
PublicationDate | 2024-July-12 |
PublicationDateYYYYMMDD | 2024-07-12 |
PublicationDate_xml | – month: 07 year: 2024 text: 2024-July-12 day: 12 |
PublicationDecade | 2020 |
PublicationTitle | 2024 4th International Conference of Science and Information Technology in Smart Administration (ICSINTESA) |
PublicationTitleAbbrev | ICSINTESA |
PublicationYear | 2024 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
Score | 1.8787163 |
Snippet | Heart rate is an important indicator of human health, reflecting physiological conditions and cardiovascular problems. Research and development in the field of... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 690 |
SubjectTerms | Accelerometer Accelerometers Accuracy Android Smartphone Frequency measurement Gyroscope Gyroscopes Heart beat Heart Rate Heart rate measurement Seismic measurements Seismocardiography Sensors Sternum Transforms |
Title | Heart Rate Measuring System using Accelerometer And Gyroscope Sensor in Android Smartphone |
URI | https://ieeexplore.ieee.org/document/10748185 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwEA-6B_FJxYnf5GGv6Zo2zdLHMZxT2BA7YfgymlwiQ2zH6B70r_fSboqC4Fu55qNcEn5317tfCOnYXIHlUjKrIGTChYopFzqmIuxgoecS7QP644kcPYn7WTLbFKvXtTDW2jr5zAb-sf6XD6VZ-1BZ1ycPeoDZJbu4z5pirT3S2fBmdu8GmeeRzfoyEkmCvl8kgm2XH5en1NgxPCCT7axNyshrsK50YD5-ETL--7MOSfu7TI8-fAHQEdmxxTF5HuHeregj2pB0XAcA8R1tiMmpz3J_oX1jEGw8TwEqlfYLoLfvntSyXFqaoVtbruii8PJVuQCaveF4PoPdtsl0eDMdjNjmAgW2SHnFEojy0EEsdCzjPOQqD1OV4rFzKgKRS5Q7ztHiAY3t0K8QMu8BpEZyZ7Uw8QlpFTj6KaGIbzYULo0gN0JqbA-ApoNBY5CnQogz0vZ6mS8bioz5ViXnf8gvyL5fHh8k5dElaVWrtb1CdK_0db2qnyFkpuE |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwEA86QX1SceK3edhru6ZNs_RxDGfVbYidMHwZbS6RIbZjdA_613tpN0VB8K1c81EuDb-7y90vhLR0KkEzIRwtwXO48aQjjWcc6WMHDR0TZjagPxyJ-InfTcLJqli9qoXRWlfJZ9q1j9VZPhRqaUNlbZs8aAFmk2wh8POwLtfaJq0Vc2b7tpdYJtmkK3wehuj9-dxdd_pxfUqFHv09MlrPWyeNvLrLMnPVxy9Kxn9_2D5pfhfq0YcvCDogGzo_JM8x_r0lfUQrkg6rECC-ozU1ObV57i-0qxTCjWUqQLXSbg705t3SWhZzTRN0bIsFneVWvihmQJM3HM_msOsmGfevx73YWV2h4MwiVjoh-KlnIOBZIILUYzL1IhnhxjPSB54KlBvG0OaBDNuhZ8FF2gGIlGBGZ1wFR6SR4-jHhCLCaY-byIdUcZFhewA0HhSagyzinJ-QptXLdF6TZEzXKjn9Q35FduLxcDAd3I7uz8iuXSobMmX-OWmUi6W-QKwvs8tqhT8BDa6qLg |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2024+4th+International+Conference+of+Science+and+Information+Technology+in+Smart+Administration+%28ICSINTESA%29&rft.atitle=Heart+Rate+Measuring+System+using+Accelerometer+And+Gyroscope+Sensor+in+Android+Smartphone&rft.au=Williamsyah%2C+Baginda+Mi%27Raj&rft.au=Rizal%2C+Achmad&rft.au=Wijaya%2C+Rifki&rft.au=Ziani%2C+Said&rft.date=2024-07-12&rft.pub=IEEE&rft.spage=690&rft.epage=695&rft_id=info:doi/10.1109%2FICSINTESA62455.2024.10748185&rft.externalDocID=10748185 |