Power System Security Restoration by Secondary Control
The paper develops a co-ordinated control scheme based on linear programming (LP) for the secondary control in a power system where it is required to restore system security in relation to voltages and power flows, and, simultaneously, minimize the network loss, following a system disturbance or con...
Saved in:
Published in | 2007 IEEE Power Engineering Society General Meeting pp. 1 - 8 |
---|---|
Main Authors | , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.06.2007
|
Subjects | |
Online Access | Get full text |
ISBN | 142441296X 9781424412969 |
ISSN | 1932-5517 |
DOI | 10.1109/PES.2007.385896 |
Cover
Abstract | The paper develops a co-ordinated control scheme based on linear programming (LP) for the secondary control in a power system where it is required to restore system security in relation to voltages and power flows, and, simultaneously, minimize the network loss, following a system disturbance or contingency. The secondary control scheme proposed is more general than the classical secondary voltage control where only voltages are considered. The scheme automatically adjusts the reference settings of the power system controllers to achieve the objectives specified in the secondary control. The algorithm is derived on the basis of the linearized power system model the parameters of which are determined online using the information obtained from the phasor measurement units and/or state estimation. The LP-based scheme is suitable for online application in secondary control. Representative results based on a test power system with FACTS devices and subject to disturbance/contingency are included in the paper. |
---|---|
AbstractList | The paper develops a co-ordinated control scheme based on linear programming (LP) for the secondary control in a power system where it is required to restore system security in relation to voltages and power flows, and, simultaneously, minimize the network loss, following a system disturbance or contingency. The secondary control scheme proposed is more general than the classical secondary voltage control where only voltages are considered. The scheme automatically adjusts the reference settings of the power system controllers to achieve the objectives specified in the secondary control. The algorithm is derived on the basis of the linearized power system model the parameters of which are determined online using the information obtained from the phasor measurement units and/or state estimation. The LP-based scheme is suitable for online application in secondary control. Representative results based on a test power system with FACTS devices and subject to disturbance/contingency are included in the paper. |
Author | Nguyen, V.L. Nguyen, T.T. |
Author_xml | – sequence: 1 givenname: T.T. surname: Nguyen fullname: Nguyen, T.T. organization: Sch. of Electr., Electron. & Comput. Eng., Univ. of Western Australia, Crawley, WA – sequence: 2 givenname: V.L. surname: Nguyen fullname: Nguyen, V.L. organization: Sch. of Electr., Electron. & Comput. Eng., Univ. of Western Australia, Crawley, WA |
BookMark | eNpFjk1LAzEYhCNWsFs9e_CSP7Brvt5scpSlVqFgcXvwVrLtG1hpN5JEZP-9WxQ8DTMDM09BZkMYkJA7zirOmX3YLNtKMFZX0oCx-oIUXAmluLBGX_4b_T4jc26lKAF4fU2KlD4YAzn1c6I34RsjbceU8URb3H_FPo_0DVMO0eU-DLQbz3kYDi6OtAlDjuF4Q668Oya8_dMF2T4tt81zuX5dvTSP67K3LJfedRJQaufN3qPsrD9Mp5yjA6ssAnhAr8EIx7wHf4ZSQqBAbYzTUsoFuf-d7RFx9xn708SwU6IGrYX8Aa2cSPY |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/PES.2007.385896 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISBN | 1424412986 9781424412983 |
EndPage | 8 |
ExternalDocumentID | 4275662 |
Genre | orig-research |
GroupedDBID | 29O 6IE 6IF 6IH 6IK 6IM AAJGR ALMA_UNASSIGNED_HOLDINGS CBEJK IPLJI M43 RIE RIO RNS |
ID | FETCH-LOGICAL-i90t-fab35e36af8cfe3b9fd14211ea5949e55f5ef6582a0ff5f0053422e2e688a6333 |
IEDL.DBID | RIE |
ISBN | 142441296X 9781424412969 |
ISSN | 1932-5517 |
IngestDate | Wed Aug 27 01:55:46 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | true |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i90t-fab35e36af8cfe3b9fd14211ea5949e55f5ef6582a0ff5f0053422e2e688a6333 |
PageCount | 8 |
ParticipantIDs | ieee_primary_4275662 |
PublicationCentury | 2000 |
PublicationDate | 2007-June |
PublicationDateYYYYMMDD | 2007-06-01 |
PublicationDate_xml | – month: 06 year: 2007 text: 2007-June |
PublicationDecade | 2000 |
PublicationTitle | 2007 IEEE Power Engineering Society General Meeting |
PublicationTitleAbbrev | PES |
PublicationYear | 2007 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0053142 ssj0001764124 |
Score | 1.6501782 |
Snippet | The paper develops a co-ordinated control scheme based on linear programming (LP) for the secondary control in a power system where it is required to restore... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | Automatic control Control systems FACTS Linear programming phasor measurement units application Power system control Power system measurements Power system modeling Power system restoration Power system security Power systems secondary control security restoration Voltage control |
Title | Power System Security Restoration by Secondary Control |
URI | https://ieeexplore.ieee.org/document/4275662 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LawIxEA7WU3vpQ0vf5NBjo9nNYzdnUaRgkWrBmySbCZSClrIe9Nc3ye5qKT30luSUTIbMZB7fh9BjZrkrXK6JSZwmvJBATGFTYlKZq0xok8cM_uRFjt_480IsWuhp3wsDALH4DHphGHP5dl1sQqiszwNWeXhwj7yaVb1ah3hKJgORcvMKe9WKxDnBPyHeK8iapi5v3-SiwXqq56rG_Emo6k-HswrYMGTMIpT_gXQl2pzRKZo0u61KTT56m9L0it0vIMf_HucMdQ_dfXi6t1vnqAWrC3TyA5iwg-Q0kKfhCs4cz2qOO_waaWjiXWKzDevrEIfY4kFV8N5F89FwPhiTmmGBvCtaEqcNE8CkdnnhgBnlrJdJkoAWiisQwglw3kVJNXVOuCBVnqaQgsxzLRljl6i9Wq_gCuGMW6MsZeD_oxy4MELLzDFaUGl0Zu016gQBLD8rDI1lffabv5dv0XFTl0eTO9QuvzZw741_aR7irX8DPSOoNQ |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LTwIxEG4IHtSLDzC-3YNHC7vbx27PBIIKhAgm3Ei7nSbGhDVmOeCvt-3ugjEevLU9tdNJZzqP70PoPtHUZCaVWEVGYppxwCrTMVYxT0XCpEp9Bn884cNX-rRgiwZ62PbCAIAvPoOOG_pcvs6ztQuVdanDKncP7p61-5SV3Vq7iErCHZVy_Q5b5fLUOc5DwdYvSOq2Lmvh-KJGe6rmokL9iULRnfZnJbShy5l5MP8d7Yq3OoMjNK73WxabvHfWhepkX7-gHP97oGPU3vX3BdOt5TpBDVidosMf0IQtxKeOPi0oAc2DWcVyF7x4Ihp_m4HauPXcRSI2Qa8seW-j-aA_7w1xxbGA30RYYCMVYUC4NGlmgChhtJVJFIFkggpgzDAw1kmJZWgMM06qNI4hBp6mkhNCzlBzla_gHAUJ1UrokID9kVKgTDHJE0PCLORKJlpfoJYTwPKjRNFYVme__Hv5Du0P5-PRcvQ4eb5CB3WVXhhdo2bxuYYb6woU6tZrwDdFZauC |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2007+IEEE+Power+Engineering+Society+General+Meeting&rft.atitle=Power+System+Security+Restoration+by+Secondary+Control&rft.au=Nguyen%2C+T.T.&rft.au=Nguyen%2C+V.L.&rft.date=2007-06-01&rft.pub=IEEE&rft.isbn=9781424412969&rft.issn=1932-5517&rft.spage=1&rft.epage=8&rft_id=info:doi/10.1109%2FPES.2007.385896&rft.externalDocID=4275662 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1932-5517&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1932-5517&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1932-5517&client=summon |