Design of intravenous infusion monitoring and alarm system based on wireless communication technology

An intravenous infusion monitoring and alarm system based on wireless transmission technology is presented. And it can real-time monitor infusion process. Alarm signal is given when the infusion is blocked or at the end of the infusion, which will solve the inconvenience of clinical intravenous infu...

Full description

Saved in:
Bibliographic Details
Published in2011 IEEE International Conference on Mechatronics and Automation pp. 130 - 134
Main Authors Cui Jianwen, Zhang Han
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.08.2011
Subjects
Online AccessGet full text

Cover

Loading…
Abstract An intravenous infusion monitoring and alarm system based on wireless transmission technology is presented. And it can real-time monitor infusion process. Alarm signal is given when the infusion is blocked or at the end of the infusion, which will solve the inconvenience of clinical intravenous infusion, and increase the security and efficiency. In this system, the photoelectric sensor technology and signal processing technology are applied to acquire the reliable detection of the infusion drops signal. And Single Chip Microcomputer (SCM) and digital display technology are used to count, display and monitor the quantity and velocity of the liquid, and alarm when there has no liquid or a block. Using wireless communication technology to realize information network and infusion status of every ward are real-time monitored in nurse station. Experimental results show that the system meet the design requirements and is safe and reliable.
AbstractList An intravenous infusion monitoring and alarm system based on wireless transmission technology is presented. And it can real-time monitor infusion process. Alarm signal is given when the infusion is blocked or at the end of the infusion, which will solve the inconvenience of clinical intravenous infusion, and increase the security and efficiency. In this system, the photoelectric sensor technology and signal processing technology are applied to acquire the reliable detection of the infusion drops signal. And Single Chip Microcomputer (SCM) and digital display technology are used to count, display and monitor the quantity and velocity of the liquid, and alarm when there has no liquid or a block. Using wireless communication technology to realize information network and infusion status of every ward are real-time monitored in nurse station. Experimental results show that the system meet the design requirements and is safe and reliable.
Author Zhang Han
Cui Jianwen
Author_xml – sequence: 1
  surname: Cui Jianwen
  fullname: Cui Jianwen
  email: cjwben@hrbeu.edu.cn
  organization: Coll. of Autom., Univ. of Harbin Eng., Harbin, China
– sequence: 2
  surname: Zhang Han
  fullname: Zhang Han
  email: pearlzhanghn@163.com
  organization: Dept. of Oral Anatomy & Physiol., Stomatology Coll. of Harbin Med. Univ., Harbin, China
BookMark eNo9UMtOwzAQNFAk2tIPQFz8Ayl-xY9jVV6Virj0wK3aJptglNgoTkH9e1JRmMuOZmZH2p2QUYgBCbnhbM45c3er5ctiLhjn89zZXCt1RiZcCaUs58qck7HguciMUm8XZOaM_fOkGP17kl-RWUofbIDWzgkxJniPydeBxor60HfwhSHu08CrffIx0DYG38fOh5pCKCk00LU0HVKPLd1BwpIOoW_fYYMp0SK27T74Avrjbo_Fe4hNrA_X5LKCJuHsNKdk8_iwWT5n69en1XKxzrxjfVZZDcxph0JbqdxOGZZDBaZQlkmwKNRwv1VcSlHkzELOKnEUTKkNsxbklNz-1npE3H52voXusD09TP4AvPldDg
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ICMA.2011.5985644
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library Online
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library Online
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 1424481147
9781424481149
1424481155
9781424481156
EISSN 2152-744X
EndPage 134
ExternalDocumentID 5985644
Genre orig-research
GroupedDBID 6IE
6IF
6IK
6IL
6IN
AAJGR
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IPLJI
OCL
RIE
RIL
RNS
ID FETCH-LOGICAL-i90t-f86a0969e268349b4705afa7c4803a8e24011841332c508a50f211847d67088a3
IEDL.DBID RIE
ISBN 9781424481132
1424481139
ISSN 2152-7431
IngestDate Wed Jun 26 19:20:32 EDT 2024
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-f86a0969e268349b4705afa7c4803a8e24011841332c508a50f211847d67088a3
PageCount 5
ParticipantIDs ieee_primary_5985644
PublicationCentury 2000
PublicationDate 2011-Aug.
PublicationDateYYYYMMDD 2011-08-01
PublicationDate_xml – month: 08
  year: 2011
  text: 2011-Aug.
PublicationDecade 2010
PublicationTitle 2011 IEEE International Conference on Mechatronics and Automation
PublicationTitleAbbrev ICMA
PublicationYear 2011
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0000669922
ssj0003010191
Score 1.5191072
Snippet An intravenous infusion monitoring and alarm system based on wireless transmission technology is presented. And it can real-time monitor infusion process....
SourceID ieee
SourceType Publisher
StartPage 130
SubjectTerms alarm
Biomedical monitoring
Chaotic communication
Computers
Hardware
Monitoring
Real time systems
SCM
Wireless communication
wireless transmission technology
Title Design of intravenous infusion monitoring and alarm system based on wireless communication technology
URI https://ieeexplore.ieee.org/document/5985644
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELbaTrDwaBFveWAkbeI4foyoUBWkIoYidavs2JEqaIpQwsCv5-w8KIiBzbYcJbYif3fn-75D6IrakBqhSWBkZgOwwHmgkpgHlMYskzqyVjii8OyRTZ_pwyJZdNB1y4Wx1vrkMzt0TX-XbzZp6UJlo0SKBPC7i7pcsoqr1cZTADpridWqHzvxNF8wz1VuDRxQNrwuEYHZ08g91X1S33hGoRzdj2c3lbhn_cIflVc88Ez20Kz55Crf5GVYFnqYfv5Sc_zvmvbR4Jvih59a8DpAHZsfot0tdcI-src-uwNvMrxyIeAPL-cK7ax0ITa89seBm4tVbrACH3mNK2Vo7MDRYJjkpJBf4TTF6TYTBRdtRH-A5pO7-Xga1FUZgpUMiyATTIHbIy1hIqZSUx4mKlM8pSKMlbBgIYDPAtAYkxSMP5WEGXED3DAOJ5qKj1Av3-T2GGGThoIbzQgHL9WAq6a50PAYY4SkWsoT1Hf7tXyrdDeW9Vad_j18hnaaeG8YnaNe8V7aCzAYCn3p_5QvG2u4iQ
link.rule.ids 309,310,780,784,789,790,796,27925,54758
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELZKGYCFR4t444ERt3k4sT2iAmqhqRiK1K2yY0eqoClCCQO_nnNeFMTAZluOEluRv7vzfd8hdEWNQzVXHtEiMQQscEZk4DNCqR8mQrnGcEsUjibh8Jk-zIJZC103XBhjTJF8Znq2Wdzl61Wc21BZPxA8APzeQJsBBTu3ZGs1ERUAz0pktez7Vj6tKJlna7cSC5U1s4u7YPjUgk9V36vuPF1H9EeD6KaU96xe-aP2SgE997soqj-6zDh56eWZ6sWfv_Qc_7uqPdT9Jvnhpwa-9lHLpAdoZ02fsIPMbZHfgVcJXtgg8Ech6ArtJLdBNrwsDgQ7F8tUYwle8hKX2tDYwqPGMMmKIb_CeYrjdS4KzpqYfhdN7--mgyGp6jKQhXAykvBQguMjjBdynwpFmRPIRLKYcseX3ICNAF4LgKPvxWD-ycBJPDvAdMjgTJP-IWqnq9QcIaxjhzOtQo-Bn6rBWVOMK3gsDD0vVkIco47dr_lbqbwxr7bq5O_hS7Q1nEbj-Xg0eTxF23X013HPUDt7z805mA-Zuij-mi8IDrvc
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2011+IEEE+International+Conference+on+Mechatronics+and+Automation&rft.atitle=Design+of+intravenous+infusion+monitoring+and+alarm+system+based+on+wireless+communication+technology&rft.au=Cui+Jianwen&rft.au=Zhang+Han&rft.date=2011-08-01&rft.pub=IEEE&rft.isbn=9781424481132&rft.issn=2152-7431&rft.eissn=2152-744X&rft.spage=130&rft.epage=134&rft_id=info:doi/10.1109%2FICMA.2011.5985644&rft.externalDocID=5985644
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2152-7431&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2152-7431&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2152-7431&client=summon