Placement of PMUs in power systems with multiple operation scenarios

This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding scenario. The optimization objective of proposed model is to minimize the number of installed PMUs and then maximize the measurement redundancy. To...

Full description

Saved in:
Bibliographic Details
Published in2013 North American Power Symposium (NAPS) pp. 1 - 5
Main Authors Lei Huang, Jian Xu, Yuanzhang Sun, Wenzhong Gao, Xiaomin Li, Jianxun Dong, Chengzhu Qi
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.09.2013
Subjects
Online AccessGet full text

Cover

Loading…
Abstract This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding scenario. The optimization objective of proposed model is to minimize the number of installed PMUs and then maximize the measurement redundancy. To take advantage of the power network topology, the effect of zero-injection bus is incorporated into the model. Furthermore, additional observability constraints for single PMU or line loss are also derived. At last, test results on IEEE 118-bus system are presented to demonstrate the effectiveness of the proposed method.
AbstractList This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding scenario. The optimization objective of proposed model is to minimize the number of installed PMUs and then maximize the measurement redundancy. To take advantage of the power network topology, the effect of zero-injection bus is incorporated into the model. Furthermore, additional observability constraints for single PMU or line loss are also derived. At last, test results on IEEE 118-bus system are presented to demonstrate the effectiveness of the proposed method.
Author Jian Xu
Lei Huang
Yuanzhang Sun
Chengzhu Qi
Xiaomin Li
Wenzhong Gao
Jianxun Dong
Author_xml – sequence: 1
  surname: Lei Huang
  fullname: Lei Huang
  email: huanglei1987@whu.edu.cn
  organization: Sch. of Electr. Eng., Wuhan Univ., Wuhan, China
– sequence: 2
  surname: Jian Xu
  fullname: Jian Xu
  organization: Sch. of Electr. Eng., Wuhan Univ., Wuhan, China
– sequence: 3
  surname: Yuanzhang Sun
  fullname: Yuanzhang Sun
  organization: Sch. of Electr. Eng., Wuhan Univ., Wuhan, China
– sequence: 4
  surname: Wenzhong Gao
  fullname: Wenzhong Gao
  email: Wenzhong.Gao@du.edu
  organization: Dept. of Electr. & Comput. Eng., Univ. of Denver, Denver, CO, USA
– sequence: 5
  surname: Xiaomin Li
  fullname: Xiaomin Li
  organization: China Power Investment Corp., China
– sequence: 6
  surname: Jianxun Dong
  fullname: Jianxun Dong
– sequence: 7
  surname: Chengzhu Qi
  fullname: Chengzhu Qi
BookMark eNotj91KwzAYQCPohZs-gHiTF2jN16RJeznmz4TpCpvXI2m-YKBNShMZe3sFd27O3YGzINchBiTkAVgJwNqnz1W3LysGvJR_NFxekQUI1bZQ1bW6Jc_doHscMWQaHe0-vhL1gU7xhDNN55RxTPTk8zcdf4bspwFpnHDW2cdAU49Bzz6mO3Lj9JDw_uIlOby-HNabYrt7e1-vtoVvWS56azi3BkFUlRLgUDjknAuQ0NTaCDTS2LY2XLmGSdU32FfWSFDWOgec8SV5_M96RDxOsx_1fD5evvgvsydIMg
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/NAPS.2013.6666836
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Xplore Digital Library
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Xplore Digital Library
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1479912557
9781479912551
EndPage 5
ExternalDocumentID 6666836
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i90t-cdb33dbe1422741fe4fe333416185ab4eb6bd95b37f8067c8ec2db617ddff1303
IEDL.DBID RIE
IngestDate Thu Jun 29 18:37:33 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-cdb33dbe1422741fe4fe333416185ab4eb6bd95b37f8067c8ec2db617ddff1303
PageCount 5
ParticipantIDs ieee_primary_6666836
PublicationCentury 2000
PublicationDate 2013-Sept.
PublicationDateYYYYMMDD 2013-09-01
PublicationDate_xml – month: 09
  year: 2013
  text: 2013-Sept.
PublicationDecade 2010
PublicationTitle 2013 North American Power Symposium (NAPS)
PublicationTitleAbbrev NAPS
PublicationYear 2013
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.5545257
Snippet This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms Controlled islanding
Educational institutions
measurement redundancy
Observability
optimal PMU placement
Phasor measurement units
Power system stability
Redundancy
State estimation
Title Placement of PMUs in power systems with multiple operation scenarios
URI https://ieeexplore.ieee.org/document/6666836
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LSwMxEB7anjyptOKbHDy620eS3eQoailCy4It9FZMMoEi7Ba7vfjrzexuK4oHbyEk5AX5vky-mQG4qzioTmU0DDdfJKzXkUmti4QPXNZLIdIBOQpPZ8lkIV6WctmC-4MvDCJW4jOMqVj95bvC7shU1g9UO1E8aUM71br21Wo-KocD3Z89ZK-k1eJx0-5HwpQKL8bHMN2PVMtE3uNdaWL7-SsI43-ncgK9b888lh0w5xRamHfhKSNbOHVghWfZdLFl65xtKP8ZqyM1bxnZW9lePciKDdYnzyiYU3guF9sezMfP88dJ1GRHiNZ6UEbWGc6dQbLhBFbgUXjknNN7Rck3I9AkxmlpeOpVQCSr0I6cCXzFOe8JuM6gkxc5ngPjxCq8EF76APZqZJLAGbhVSqJUbuguoEsbsNrU8S9Wzdov_66-gqNRlTKCdFjX0Ck_dngTgLs0t9WJfQHUCpqV
link.rule.ids 310,311,783,787,792,793,799,27937,55086
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LSwMxEB5qPehJpRXf5uDRbB9JdrNHUUvVblmwhd6KeUERdovdXvz1Zna3FcWDtxAS8oJ8XybfzADclBw0jgTt-ZuPcu1iqiJtKHeeyzrBedRFR-FkHA6n_HkmZg243frCWGtL8ZkNsFj-5Ztcr9FU1vFUO5Qs3IFdz6tlWHlr1V-VvW7cGd-lr6jWYkHd8kfKlBIxBgeQbMaqhCLvwbpQgf78FYbxv5M5hPa3bx5Jt6hzBA2bteAhRWs4diC5I2kyXZFFRpaYAY1UsZpXBC2uZKMfJPnSVmdPMJyTfzDnqzZMBo-T-yGt8yPQRdwtqDaKMaMsWnE8L3CWO8sYwxeLFG-KWxUqEwvFIic9Jmlpdd8oz1iMcQ6h6xiaWZ7ZEyAMeYXj3Ann4V72VehZA9NSCiuk6ZlTaOEGzJdVBIx5vfazv6uvYW84SUbz0dP45Rz2-2UCCVRlXUCz-FjbSw_jhboqT-8LGDKd4A
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2013+North+American+Power+Symposium+%28NAPS%29&rft.atitle=Placement+of+PMUs+in+power+systems+with+multiple+operation+scenarios&rft.au=Lei+Huang&rft.au=Jian+Xu&rft.au=Yuanzhang+Sun&rft.au=Wenzhong+Gao&rft.date=2013-09-01&rft.pub=IEEE&rft.spage=1&rft.epage=5&rft_id=info:doi/10.1109%2FNAPS.2013.6666836&rft.externalDocID=6666836