Investigation of active damping methods for model-based-current-control scheme of single-phase grid-tied VSI with LCL filter

In this paper, the performances of various active damping methods for model-based-current-control (MBCC) of single-phase grid-tied LCL-filtered voltage source inverters (VSIs) are investigated. It is shown that the proposed MBCC approach enforces the inverter current to track its reference in all ci...

Full description

Saved in:
Bibliographic Details
Published inIECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society pp. 1261 - 1266
Main Authors Komurcugil, Hasan, Kukrer, Osman
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.10.2017
Subjects
Online AccessGet full text
DOI10.1109/IECON.2017.8216215

Cover

Abstract In this paper, the performances of various active damping methods for model-based-current-control (MBCC) of single-phase grid-tied LCL-filtered voltage source inverters (VSIs) are investigated. It is shown that the proposed MBCC approach enforces the inverter current to track its reference in all circumstances provided that the inverter current reference is generated accurately. In this study, a proportional-resonant (PR) controller is used to generate the inverter current reference. Also, it is shown that the dynamics of this tracking can be made faster by adding an additional virtual time constant into the control variable equation. In spite of these features, the closed-loop system is subject to the adverse effects of the LCL resonance. Therefore, the possibilities of adding various active damping methods into the closed-loop system are investigated. Computer simulations are conducted to show the performance of the proposed MBCC approach with various active damping methods.
AbstractList In this paper, the performances of various active damping methods for model-based-current-control (MBCC) of single-phase grid-tied LCL-filtered voltage source inverters (VSIs) are investigated. It is shown that the proposed MBCC approach enforces the inverter current to track its reference in all circumstances provided that the inverter current reference is generated accurately. In this study, a proportional-resonant (PR) controller is used to generate the inverter current reference. Also, it is shown that the dynamics of this tracking can be made faster by adding an additional virtual time constant into the control variable equation. In spite of these features, the closed-loop system is subject to the adverse effects of the LCL resonance. Therefore, the possibilities of adding various active damping methods into the closed-loop system are investigated. Computer simulations are conducted to show the performance of the proposed MBCC approach with various active damping methods.
Author Kukrer, Osman
Komurcugil, Hasan
Author_xml – sequence: 1
  givenname: Hasan
  surname: Komurcugil
  fullname: Komurcugil, Hasan
  email: hasan.komurcugil@emu.edu.tr
  organization: Dept. of Comput. Eng., Eastern Mediterranean Univ., Famagusta, Turkey
– sequence: 2
  givenname: Osman
  surname: Kukrer
  fullname: Kukrer, Osman
  email: osman.kukrer@emu.edu.tr
  organization: Dept. of Electr. & Electron. Eng., Eastern Mediterranean Univ., Famagusta, Turkey
BookMark eNotkMFKxDAYhCPoQdd9Ab3kBVKbtNskRymrFop7cPG6JM2fbaBNShpXBB_eLu5pGJj5BuYOXfvgAaEHmmeU5vKp2da794zllGeC0YrRzRVaSy7ophAVpYyzW_Tb-BPMyR1VcsHjYLHqkjsBNmqcnD_iEVIfzIxtiHgMBgai1QyGdF8xgk-kCz7FMOC562GEM2BeagOQqV9y-BidIcmBwZ8fDf52qcdt3WLrhgTxHt1YNcywvugK7V-2-_qNtLvXpn5uiZP5siBswZWVWpeKMyZELouOF1UppODWQqmV6QSzIFll843Qmi0WtFDWMK5ksUKP_1gHAIcpulHFn8PlkuIPYC1dRQ
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/IECON.2017.8216215
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Xplore
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Xplore
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9781538611272
1538611279
EndPage 1266
ExternalDocumentID 8216215
Genre orig-research
GroupedDBID 6IE
6IH
CBEJK
RIE
RIO
ID FETCH-LOGICAL-i90t-c8f37af9bb4a72288093c73648987ffe4badc82fe926f058bb2c82eb8afd27a93
IEDL.DBID RIE
IngestDate Thu Jun 29 18:37:41 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-c8f37af9bb4a72288093c73648987ffe4badc82fe926f058bb2c82eb8afd27a93
PageCount 6
ParticipantIDs ieee_primary_8216215
PublicationCentury 2000
PublicationDate 2017-Oct.
PublicationDateYYYYMMDD 2017-10-01
PublicationDate_xml – month: 10
  year: 2017
  text: 2017-Oct.
PublicationDecade 2010
PublicationTitle IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society
PublicationTitleAbbrev IECON
PublicationYear 2017
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.6492078
Snippet In this paper, the performances of various active damping methods for model-based-current-control (MBCC) of single-phase grid-tied LCL-filtered voltage source...
SourceID ieee
SourceType Publisher
StartPage 1261
SubjectTerms active damping
Closed loop systems
Current measurement
Damping
Grid-tied inverter
Inverters
LCL filter
Power harmonic filters
proportional-resonant control
Resistors
Transfer functions
Title Investigation of active damping methods for model-based-current-control scheme of single-phase grid-tied VSI with LCL filter
URI https://ieeexplore.ieee.org/document/8216215
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELZKJyZALeItD4w4bew87LmialGLkCioW-XXQQVNqpIuiB-PnaTlIQa2JLJsy3b8nc_33YfQJbMhV1Qoop01TiILhnDQligBbm8MtaGRJyePb5PBQ3QzjacNdLXlwlhry-AzG_jH8i7f5HrtXWUdTsOEekb5jltmFVdrw4Ppis7QS__5YK00qAv-UEwpAaO_h8abpqo4kZdgXahAv__Kwvjfvuyj9hc1D99tQecANWzWQh_fsmXkGc4By3Ibw0YuPB8KVzrRb9hZqLjUviEevQzRVXYmUgesY3fUtQvrK_AuhFdLls-uHH5azQ0pnLGKH--H2Ltu8ag3wjD3V-1tNOlfT3oDUssqkLnouho5sFSCUCqSKaXu_xVMpyyJuOApgI2UNJpTsIIm0I25UtS9WsUlGJpKwQ5RM8sze4RwaBQ4bFNMuUOiASUZTYVKTAwhMGriY9TyAzdbVokzZvWYnfz9-RTt-smrIuXOULNYre25Q_xCXZRT_QkUXbEi
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NT8IwGG4IHvSkBozf9uDRDtbuoz0TCSgQE9FwI33XVomyERwX44-33QZ-xIO3bWm6pc36vH37PO-D0CXTPgcqgCQ2GieBNopwk2gCwti10U8UDZw4eTiKeg_BzSSc1NDVRgujtS7IZ9pzl8VZvsqSlUuVtTj1I-oU5VsW94OwVGutlTBt0eo78z9H14q9qukPz5QCMrq7aLh-WckUefFWOXjJ-686jP_9mj3U_BLn4bsN7Oyjmk4b6ONbvYwsxZnBsljIsJJzp4jCpVP0G7YxKi7cb4jDL0WSsj4TqSjr2G529Vy7DlwS4VWTxbNth5-WM0VyG67ix_s-dslbPOgMsJm5w_YmGnevx50eqYwVyEy0bY_csFgaARDImFL7BwuWxCwKuOCxMToAqRJOjRY0Mu2QA1B7q4FLo2gsBTtA9TRL9SHCvgJj0Q0Y2G2iMiAZjQVEKjS-YVSFR6jhBm66KEtnTKsxO_778QXa7o2Hg-mgP7o9QTtuIkve3Cmq58uVPrP4n8N5Me2fg0C0bw
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=IECON+2017+-+43rd+Annual+Conference+of+the+IEEE+Industrial+Electronics+Society&rft.atitle=Investigation+of+active+damping+methods+for+model-based-current-control+scheme+of+single-phase+grid-tied+VSI+with+LCL+filter&rft.au=Komurcugil%2C+Hasan&rft.au=Kukrer%2C+Osman&rft.date=2017-10-01&rft.pub=IEEE&rft.spage=1261&rft.epage=1266&rft_id=info:doi/10.1109%2FIECON.2017.8216215&rft.externalDocID=8216215