Removal of Baseline Wander from Dynamic Electrocardiogram Signals
The traditional method based on moving average filter can remove the baseline wander in electrocardiogram signals, but also causes the loss of motive ECG signals, which makes distortions of filtered ECG signals. In this paper, a modified moving average filter is proposed to selectively capture the l...
Saved in:
Published in | 2009 2nd International Congress on Image and Signal Processing pp. 1 - 4 |
---|---|
Main Authors | , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.10.2009
|
Subjects | |
Online Access | Get full text |
ISBN | 1424441293 9781424441297 |
DOI | 10.1109/CISP.2009.5304473 |
Cover
Loading…
Abstract | The traditional method based on moving average filter can remove the baseline wander in electrocardiogram signals, but also causes the loss of motive ECG signals, which makes distortions of filtered ECG signals. In this paper, a modified moving average filter is proposed to selectively capture the low-frequency baseline wander noise and remove it from the detected signals in order to recover true ECG. The interval sampling data is taken into consideration when calculate the moving average in order to reduce the loss of useful ECG signals and distortions. The algorithm is developed for computer implementation using MATLAB. To validate the proposed methods, the recording from MIT/BIH database is used. Experimental results demonstrate the improvement of the proposed moving average filter over the traditional one in removing baseline wander without introducing distortion to the ECG signals. |
---|---|
AbstractList | The traditional method based on moving average filter can remove the baseline wander in electrocardiogram signals, but also causes the loss of motive ECG signals, which makes distortions of filtered ECG signals. In this paper, a modified moving average filter is proposed to selectively capture the low-frequency baseline wander noise and remove it from the detected signals in order to recover true ECG. The interval sampling data is taken into consideration when calculate the moving average in order to reduce the loss of useful ECG signals and distortions. The algorithm is developed for computer implementation using MATLAB. To validate the proposed methods, the recording from MIT/BIH database is used. Experimental results demonstrate the improvement of the proposed moving average filter over the traditional one in removing baseline wander without introducing distortion to the ECG signals. |
Author | Min Dai Shi-Liu Lian |
Author_xml | – sequence: 1 surname: Min Dai fullname: Min Dai organization: Sch. of Comput. & Commun. Eng., Tianjin Univ. of Technol., Tianjin, China – sequence: 2 surname: Shi-Liu Lian fullname: Shi-Liu Lian organization: Sch. of Comput. & Commun. Eng., Tianjin Univ. of Technol., Tianjin, China |
BookMark | eNo9j81Kw0AURke0oKl9AHEzL5B65y_JLGusWigotuCy3JnclIFkIpMi9O2tWFwdPvg4cDJ2FYdIjN0JmAsB9qFebd7nEsDOjQKtS3XBMqGl1looYS7_h7RqwrLfowWhZHnNZuMYHMjCGGtKc8MWH9QP39jxoeWPOFIXIvFPjA0l3qah50_HiH3wfNmRP6TBY2rCsE_Y803YR-zGWzZpT6DZmVO2fV5u69d8_fayqhfrPFg45I7KRlowiBoK06KTFVmjGygQwRtXOVU4USpHp8DGeoveGlNUCKpxqq3UlN3_aQMR7b5S6DEdd-d89QN3hE36 |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/CISP.2009.5304473 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE/IET Electronic Library IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 1424441315 9781424441310 |
EndPage | 4 |
ExternalDocumentID | 5304473 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IK 6IL 6IN AAJGR AARBI AAWTH ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK IERZE OCL RIE RIL |
ID | FETCH-LOGICAL-i90t-be7d2905aa4065fab28e954d06aa0c5b8b36b173be110d9c9ac95568a03db3f83 |
IEDL.DBID | RIE |
ISBN | 1424441293 9781424441297 |
IngestDate | Wed Aug 27 02:26:29 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
LCCN | 2009901327 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i90t-be7d2905aa4065fab28e954d06aa0c5b8b36b173be110d9c9ac95568a03db3f83 |
PageCount | 4 |
ParticipantIDs | ieee_primary_5304473 |
PublicationCentury | 2000 |
PublicationDate | 2009-Oct. |
PublicationDateYYYYMMDD | 2009-10-01 |
PublicationDate_xml | – month: 10 year: 2009 text: 2009-Oct. |
PublicationDecade | 2000 |
PublicationTitle | 2009 2nd International Congress on Image and Signal Processing |
PublicationTitleAbbrev | CISP |
PublicationYear | 2009 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssib026559575 |
Score | 1.5147424 |
Snippet | The traditional method based on moving average filter can remove the baseline wander in electrocardiogram signals, but also causes the loss of motive ECG... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | Adaptive filters Clinical diagnosis Computer vision Distortion Electrocardiography Electrodes Finite impulse response filter Frequency IIR filters Low-frequency noise |
Title | Removal of Baseline Wander from Dynamic Electrocardiogram Signals |
URI | https://ieeexplore.ieee.org/document/5304473 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV09T8MwED21nZgAtYhveWAkaRIncTxCaVWQiipaRLfKds6oQjQVShd-PbaTFIEY2OIMlr-kd_a99w7gKpMsRKaVx-z7mwngtSeQpZ6QnHHBKHKXLpg8puPn-GGRLFpwvdPCIKIjn6FvP10uPy_U1j6V9RNz944ZbUPbXNwqrVZzdqLUhMYm9Gi0W7HFscbSqW6zOqsZBrw_uJ9NK7fKutMf1VUcuIz2YdIMq-KUvPnbUvrq85dj43_HfQC9bxkfme4A6hBauO7CzRO-F-Z4kUKTW-Hk6EhenMaFWK0Juatq1JNhVSBHOcKq5XCR2erVui33YD4azgdjr66j4K14UHoSWR7xIBHCgHeihYwy5EmcB6kQgUpkJmkqQ0YlmpXJueJCcetLJgKaS6ozegSddbHGYyBMSI15qKlGFSM1rZClKmOKK2FwH0-ga2e_3FROGct64qd__z6DPZebcdS4c-iUH1u8MBBfyku3t1_zn6NT |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PT8IwFH5BPOhJDRh_24NHBxvd1vWoCAEFQgQjN9J2r4YYmTHj4l9v2w2MxoO3toel7Zp8r33f9z2Aq0SyAJlWHrPvbyaA155AFntCcsYFo8hdumA4intP4f0smlXgeqOFQURHPsOGbbpcfpqplX0qa0bm7h0yugXbkRXjFmqt9elpxSY4NsHHWr0VWiRbmzqVfVbmNQOfN9v9ybjwqyw_-6O-ioOX7h4M1xMrWCWvjVUuG-rzl2fjf2e-D_VvIR8ZbyDqACq4rMHNI75l5oCRTJNb4QTpSJ6dyoVYtQm5K6rUk05RIkc5yqplcZHJ4sX6Lddh2u1M2z2vrKTgLbifexJZ2uJ-JISB70gL2UqQR2Hqx0L4KpKJpLEMGJVodibligvFrTOZ8GkqqU7oIVSX2RKPgDAhNaaBphpViNT0AharhCmuhEF-PIaaXf38vfDKmJcLP_l7-BJ2etPhYD7ojx5OYddlahxR7gyq-ccKzw3g5_LC_ecvq9mmmw |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2009+2nd+International+Congress+on+Image+and+Signal+Processing&rft.atitle=Removal+of+Baseline+Wander+from+Dynamic+Electrocardiogram+Signals&rft.au=Min+Dai&rft.au=Shi-Liu+Lian&rft.date=2009-10-01&rft.pub=IEEE&rft.isbn=9781424441297&rft.spage=1&rft.epage=4&rft_id=info:doi/10.1109%2FCISP.2009.5304473&rft.externalDocID=5304473 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424441297/lc.gif&client=summon&freeimage=true |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424441297/mc.gif&client=summon&freeimage=true |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424441297/sc.gif&client=summon&freeimage=true |