Diagnosis of Capsulated SF6 High Voltage Switching Devices

This paper aims to discuss some major and important issues concerning the predictive maintenance of high voltage devices (switches, surge-arresters, etc.). Real data was mainly obtained from the industrial environment and used for establishing a monitoring and diagnosing digital based procedure, for...

Full description

Saved in:
Bibliographic Details
Published in2019 International Conference on ENERGY and ENVIRONMENT (CIEM) pp. 78 - 81
Main Authors Frigura-Iliasa, Flaviu Mihai, Vatau, Doru, Borlea, Ioan, Vasil, Radu, Demeter, Francisc, Bran, Mariana
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.10.2019
Subjects
Online AccessGet full text

Cover

Loading…
Abstract This paper aims to discuss some major and important issues concerning the predictive maintenance of high voltage devices (switches, surge-arresters, etc.). Real data was mainly obtained from the industrial environment and used for establishing a monitoring and diagnosing digital based procedure, for efficiently testing the technical state of their main HV contacts. All solutions described here are applicable to many other high voltage devices like surge-arresters, disconnectors etc. A simple fuzzy-logic algorithm is used to determine the main elements related to the predictive maintenance. This algorithm could be implemented as a software tools for all high voltage equipment maintenance. It could be an example of implementing advanced mathematical and software solution for the refurbishment of existing high voltage equipment.
AbstractList This paper aims to discuss some major and important issues concerning the predictive maintenance of high voltage devices (switches, surge-arresters, etc.). Real data was mainly obtained from the industrial environment and used for establishing a monitoring and diagnosing digital based procedure, for efficiently testing the technical state of their main HV contacts. All solutions described here are applicable to many other high voltage devices like surge-arresters, disconnectors etc. A simple fuzzy-logic algorithm is used to determine the main elements related to the predictive maintenance. This algorithm could be implemented as a software tools for all high voltage equipment maintenance. It could be an example of implementing advanced mathematical and software solution for the refurbishment of existing high voltage equipment.
Author Vatau, Doru
Frigura-Iliasa, Flaviu Mihai
Borlea, Ioan
Demeter, Francisc
Vasil, Radu
Bran, Mariana
Author_xml – sequence: 1
  givenname: Flaviu Mihai
  surname: Frigura-Iliasa
  fullname: Frigura-Iliasa, Flaviu Mihai
  organization: POLITEHNICA University of Timisoara,Power Systems Department,Timisoara,Romania
– sequence: 2
  givenname: Doru
  surname: Vatau
  fullname: Vatau, Doru
  organization: POLITEHNICA University of Timisoara,Power Systems Department,Timisoara,Romania
– sequence: 3
  givenname: Ioan
  surname: Borlea
  fullname: Borlea, Ioan
  organization: POLITEHNICA University of Timisoara,Power Systems Department,Timisoara,Romania
– sequence: 4
  givenname: Radu
  surname: Vasil
  fullname: Vasil, Radu
  organization: POLITEHNICA University of Timisoara,Faculty of Electrical and Power Engineering,Timisoara,Romania
– sequence: 5
  givenname: Francisc
  surname: Demeter
  fullname: Demeter, Francisc
  organization: POLITEHNICA University of Timisoara,Faculty of Electrical and Power Engineering,Timisoara,Romania
– sequence: 6
  givenname: Mariana
  surname: Bran
  fullname: Bran, Mariana
  organization: POLITEHNICA University of Timisoara,Faculty of Electrical and Power Engineering,Timisoara,Romania
BookMark eNotj8tKAzEUQCPowla_QJD8wIy5ec3EnUxbW6i4aHFbbtKbaWCcKc2o-PcK7epsDgfOhF33Q0-MPYIoAYR7albzN221saUU4MraqcpYfcUmUMkawCjpbtnzLGHbDzllPkTe4DF_dTjSnm8Wli9Te-AfQzdiS3zzk8ZwSH3LZ_SdAuU7dhOxy3R_4ZRtF_NtsyzW76-r5mVdJCfGwttQVaQ9Ka0NRI0ueNgjyjrW4KLyzhJ6skIHgQDSSq-kMeC09cL8C1P2cM4mItodT-kTT7-7y436A6VFQ60
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/CIEM46456.2019.8937564
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library Online
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library Online
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1728115329
9781728115320
EndPage 81
ExternalDocumentID 8937564
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i90t-b6c77e4be34451f4a9cb1daa28f819f3b96eabe604c0a11262b32551946b059f3
IEDL.DBID RIE
IngestDate Thu Jun 29 18:39:22 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-b6c77e4be34451f4a9cb1daa28f819f3b96eabe604c0a11262b32551946b059f3
PageCount 4
ParticipantIDs ieee_primary_8937564
PublicationCentury 2000
PublicationDate 2019-Oct.
PublicationDateYYYYMMDD 2019-10-01
PublicationDate_xml – month: 10
  year: 2019
  text: 2019-Oct.
PublicationDecade 2010
PublicationTitle 2019 International Conference on ENERGY and ENVIRONMENT (CIEM)
PublicationTitleAbbrev CIEM
PublicationYear 2019
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.7461326
Snippet This paper aims to discuss some major and important issues concerning the predictive maintenance of high voltage devices (switches, surge-arresters, etc.)....
SourceID ieee
SourceType Publisher
StartPage 78
SubjectTerms Contact resistance
contacts
Electrical resistance measurement
high voltage
High-voltage techniques
Maintenance engineering
Monitoring
power equipment
Switches
Title Diagnosis of Capsulated SF6 High Voltage Switching Devices
URI https://ieeexplore.ieee.org/document/8937564
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NSwMxEB3anjyptOI3OXh0290mm2689oMqVIRW6a0k2QkUS1d0i-Cvd5KtFcWDt7Ak7OaDvJnNey8AVxQBuyxBylRtKiORYi_SBBORd4pxSEl2Gny2J_dy_Cju5um8Btc7LQwiBvIZtn0xnOXnhd34X2Udj62pFHWoZ3G30mptRb9JrDr92-HEn9N54kFCK6Cq_OPWlAAao32YfL2u4oo8tzeladuPX06M__2eA2h9y_PYww54DqGG6ybcDCrS3PKNFY71NWW_K4ojczYdSebZHOypWJW0e7Dp-7IMDEo2wLBPtGA2Gs7642h7MUK0VHEZGWl7PRQGuXcXc0Ira5Jc625Gw64cN0qiNihjYWPtJUJdwylzSJSQhqIpx4-gsS7WeAzMeXcZTm0Nz4TlUts8y6w1RqrEoeUn0PTdXrxU1heLbY9P_358Bnt-6Cuu2zk0ytcNXhBml-YyTNYn4AOXPw
link.rule.ids 310,311,786,790,795,796,802,27958,55109
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PT8IwFH5BPOhJDRh_24NHBxvtyuaVHwFlxAQ03EjbvSZEwoyOmPjX-7qhRuPBW9ds2dou_d5rv-8rwBVFwDYKkDJVE0pPhNj2FMGE55xiLFKSHRY-28lYDh7E7SycVeD6SwuDiAX5DBuuWOzlp5lZu6WypsPWUIot2Cac9-NSrbWR_dJ1szPsJW6nzlEPAvoHytt_nJtSwEZ_D5LPF5ZskafGOtcN8_7Li_G_X7QP9W-BHrv_gp4DqOCqBjfdkja3eGWZZR1F-e-SIsmUTfqSOT4He8yWOc0fbPK2yAsOJetiMVPUYdrvTTsDb3M0greI_dzT0rTbKDRy5y9mhYqNDlKlWhF1fGy5jiUqjdIXxldOJNTSnHKHIBZSUzxl-SFUV9kKj4BZ5y_D6VnNI2G4VCaNImO0lnFg0fBjqLlmz59L84v5psUnf1dfws5gmozmo-H47hR23TCUzLczqOYvazwnBM_1RTFwHw0RmpU
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2019+International+Conference+on+ENERGY+and+ENVIRONMENT+%28CIEM%29&rft.atitle=Diagnosis+of+Capsulated+SF6+High+Voltage+Switching+Devices&rft.au=Frigura-Iliasa%2C+Flaviu+Mihai&rft.au=Vatau%2C+Doru&rft.au=Borlea%2C+Ioan&rft.au=Vasil%2C+Radu&rft.date=2019-10-01&rft.pub=IEEE&rft.spage=78&rft.epage=81&rft_id=info:doi/10.1109%2FCIEM46456.2019.8937564&rft.externalDocID=8937564