Island Mode Operation (IMO) for Gas Combined SPP Plants

In SPP (Small Power Producers) plants, especially in Thailand, maximum amount of generating power to the Utility Power Grid is limited and balance electric power as well as heat energy is supplied to industrial users (IUs). Sudden isolation of the grid connection may take place by various reasons, m...

Full description

Saved in:
Bibliographic Details
Published in2019 IEEE PES GTD Grand International Conference and Exposition Asia (GTD Asia) pp. 35 - 39
Main Authors Vedwal, Shailendra, Sasaki, Tatsuyuki, Ogura, Minoru
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.03.2019
Subjects
Online AccessGet full text

Cover

Loading…
Abstract In SPP (Small Power Producers) plants, especially in Thailand, maximum amount of generating power to the Utility Power Grid is limited and balance electric power as well as heat energy is supplied to industrial users (IUs). Sudden isolation of the grid connection may take place by various reasons, meaning that generating power to the Utility Power Grid from the plant has to be reduced instantly and thereafter the plant continues to supply electric power and heat to IUs (called Island Mode Operation (IMO)). Special system consideration has to be made to keep stable operation of electrical as well as heat energy supply to the IUs in case of such operation.This paper explains how the system design considerations and operational scenarios are made to achieve the stable operation and secure transition from normal to island operation mode.
AbstractList In SPP (Small Power Producers) plants, especially in Thailand, maximum amount of generating power to the Utility Power Grid is limited and balance electric power as well as heat energy is supplied to industrial users (IUs). Sudden isolation of the grid connection may take place by various reasons, meaning that generating power to the Utility Power Grid from the plant has to be reduced instantly and thereafter the plant continues to supply electric power and heat to IUs (called Island Mode Operation (IMO)). Special system consideration has to be made to keep stable operation of electrical as well as heat energy supply to the IUs in case of such operation.This paper explains how the system design considerations and operational scenarios are made to achieve the stable operation and secure transition from normal to island operation mode.
Author Ogura, Minoru
Vedwal, Shailendra
Sasaki, Tatsuyuki
Author_xml – sequence: 1
  givenname: Shailendra
  surname: Vedwal
  fullname: Vedwal, Shailendra
  organization: Toshiba Plant Systems & Services Corporation, Tsurumi, Yokohama, Japan
– sequence: 2
  givenname: Tatsuyuki
  surname: Sasaki
  fullname: Sasaki, Tatsuyuki
  organization: Toshiba Plant Systems & Services Corporation, Tsurumi, Yokohama, Japan
– sequence: 3
  givenname: Minoru
  surname: Ogura
  fullname: Ogura, Minoru
  organization: Toshiba Plant Systems & Services Corporation, Tsurumi, Yokohama, Japan
BookMark eNotj71qwzAYRVVohzbNE6SDxnawa_1LY3Ab15BgQ7wHKfoEgkQKtpe-fQ3NdOByuHBe0GPKCRB6I1VJSGU-m-FrO0Vb0oqYUisiFz6gtVGaCKal4oyLZ6Ta6WKTx4fsAXc3GO0cc8Lv7aH7wCGPuLETrvPVxQQeH_se94s_T6_oKdjLBOs7V2jYfQ_1T7Hvmrbe7otoqrlwAjzhLHDmmdHEkEC4VmfJHA-KOgZcnb0I0itFZQVBeCq4tsbxZaBSsBXa_N9GADjdxni14-_pXsP-AI0EQaE
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/GTDAsia.2019.8716019
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library Online
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9781538674345
1538674343
EndPage 39
ExternalDocumentID 8716019
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i90t-b5ed143f43d398191f1487c63b4f72b3e47cd5f6d77260ef5d2548a9b47722653
IEDL.DBID RIE
IngestDate Wed Jun 26 19:27:58 EDT 2024
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-b5ed143f43d398191f1487c63b4f72b3e47cd5f6d77260ef5d2548a9b47722653
PageCount 5
ParticipantIDs ieee_primary_8716019
PublicationCentury 2000
PublicationDate 2019-March
PublicationDateYYYYMMDD 2019-03-01
PublicationDate_xml – month: 03
  year: 2019
  text: 2019-March
PublicationDecade 2010
PublicationTitle 2019 IEEE PES GTD Grand International Conference and Exposition Asia (GTD Asia)
PublicationTitleAbbrev GTDAsia
PublicationYear 2019
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.732788
Snippet In SPP (Small Power Producers) plants, especially in Thailand, maximum amount of generating power to the Utility Power Grid is limited and balance electric...
SourceID ieee
SourceType Publisher
StartPage 35
SubjectTerms Generator Operating Pattern
Island Mode Operation
Power Plant
Title Island Mode Operation (IMO) for Gas Combined SPP Plants
URI https://ieeexplore.ieee.org/document/8716019
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NSwMxEA21J08qrfhNDh4U3DZtdpPmKGpbhdqCFXorm8wEirAt7vbirzezWyuKB29LWNhNhjDvJfPeMHYZQJtBl2IESpOpthVRzzoZJSEXA0Dqu5bOIUfPavgaP82SWY3dbLUwiFgWn2GLHsu7fFi6NR2VtQncC_L43NHGVFqtjRquI0x7ML2_zRfkJdQJ8a9e_dEzpUwZ_T02-vpYVSny1loXtuU-fvkw_vdv9lnzW5zHJ9u0c8BqmDWYptBmwKm1GR-vsIorv3ocja95wKV8kOY87P3AgxH4y2TCqVtRkTfZtP8wvRtGm54I0cKIIrIJQkA4PpYgDXEtH-iMdkra2OuulRhrB4lXEECzEugTCASwlxobh4GuSuQhq2fLDI8YV6Q7kF4CBpJnJBqnhQdUQiP6VPSOWYPmPF9VrhfzzXRP_h4-Zbu07lV11hmrF-9rPA_purAXZZw-AbcrlQ8
link.rule.ids 310,311,783,787,792,793,799,27937,55086
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA5jHvSksom_zcGDgt2ypU2ao6j7oes2sMJuo2leYAy64bqLf70v7ZwoHryVUGjCS3nfl7zve4RcI2hTkCbgGSGdqbZmXqhT7gWYi40xiW1rdw4ZDUXvzX-eBJMKudtqYQCgKD6Dhnss7vLNIl27o7KmA_fMeXzuIK4ORanW2ujhWkw1u_Hj_Wrm3IRauAPKl390TSmSRmefRF-fK2tF5o11rhvpxy8nxv_O54DUv-V5dLxNPIekAlmNSBfczFDX3IyOllBGlt70o9EtRWRKu8mK4t-PTBgMfR2PqetXlK_qJO48xQ89b9MVwZsplns6AIMYx_rccOXYlkVCI1PBtW9lW3PwZWoCKwzCZsHABgYpYJgo7eNAWwT8iFSzRQbHhAqnPOCWG0CapzioVDJrQDAJYBMWnpCaW_N0WfpeTDfLPf17-Irs9uJoMB30hy9nZM_FoKzVOifV_H0NF5i8c31ZxOwTtzSYWg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2019+IEEE+PES+GTD+Grand+International+Conference+and+Exposition+Asia+%28GTD+Asia%29&rft.atitle=Island+Mode+Operation+%28IMO%29+for+Gas+Combined+SPP+Plants&rft.au=Vedwal%2C+Shailendra&rft.au=Sasaki%2C+Tatsuyuki&rft.au=Ogura%2C+Minoru&rft.date=2019-03-01&rft.pub=IEEE&rft.spage=35&rft.epage=39&rft_id=info:doi/10.1109%2FGTDAsia.2019.8716019&rft.externalDocID=8716019