Voltage sag/swell compensation using Z-Source inverter based dynamic voltage restorer

This paper presents the modeling and simulation of a dynamic voltage restorer as a voltage sag/swell mitigation device in electrical power distribution networks. The dynamic voltage restorer, with its excellent dynamic capabilities, when installed between the supply and a critical load feeder, can c...

Full description

Saved in:
Bibliographic Details
Published in2011 International Conference on Emerging Trends in Electrical and Computer Technology pp. 268 - 273
Main Authors Usha, R P, Rajkumar, M, Reddy, S R
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.03.2011
Subjects
Online AccessGet full text
ISBN1424479231
9781424479238
DOI10.1109/ICETECT.2011.5760127

Cover

Loading…
Abstract This paper presents the modeling and simulation of a dynamic voltage restorer as a voltage sag/swell mitigation device in electrical power distribution networks. The dynamic voltage restorer, with its excellent dynamic capabilities, when installed between the supply and a critical load feeder, can compensate for voltage sags/swells, restoring line voltage to its nominal value within few milliseconds and hence avoiding any power disruption to the load. A new topology based on Z-source inverter is presented in order to enhance the voltage restoration property of dynamic voltage restorer. Z-source inverter would ensure a constant DC voltage across the DC-link during the process of voltage compensation. The modeling of Z-source based dynamic voltage restorer is carried out component wise and their performances are analyzed using MATLAB software. The simulation results shows that the control technique is very effective and yields excellent compensation for voltage sag/swell mitigation.
AbstractList This paper presents the modeling and simulation of a dynamic voltage restorer as a voltage sag/swell mitigation device in electrical power distribution networks. The dynamic voltage restorer, with its excellent dynamic capabilities, when installed between the supply and a critical load feeder, can compensate for voltage sags/swells, restoring line voltage to its nominal value within few milliseconds and hence avoiding any power disruption to the load. A new topology based on Z-source inverter is presented in order to enhance the voltage restoration property of dynamic voltage restorer. Z-source inverter would ensure a constant DC voltage across the DC-link during the process of voltage compensation. The modeling of Z-source based dynamic voltage restorer is carried out component wise and their performances are analyzed using MATLAB software. The simulation results shows that the control technique is very effective and yields excellent compensation for voltage sag/swell mitigation.
Author Rajkumar, M
Usha, R P
Reddy, S R
Author_xml – sequence: 1
  givenname: R P
  surname: Usha
  fullname: Usha, R P
  email: pusharani71@yahoo.com
  organization: EEE Dept., Jerusalem Coll. of Eng., Chennai, India
– sequence: 2
  givenname: M
  surname: Rajkumar
  fullname: Rajkumar, M
  email: rajkumar_mahewaran@yahoo.co.in
  organization: Power Electron. & Drives, Jerusalem Coll. of Eng., Chennai, India
– sequence: 3
  givenname: S R
  surname: Reddy
  fullname: Reddy, S R
  email: srr_victory@yahoo.com
  organization: EEE Dept., Jerusalem Coll. of Eng., Chennai, India
BookMark eNpFkEFLwzAYhiMq6OZ-gR7yB9olaZo2RylVBwMPVg9extf0S4m06Ui6yf69ggPfy8NzeQ7vglz5ySMhD5ylnDO93lR1U1dNKhjnaV4oxkVxQRZcCikLLZS6_JeM35BVjF_sd0ppofUtef-Yhhl6pBH6dfzGYaBmGvfoI8xu8vQQne_pZ_I2HYJB6vwRw4yBthCxo93Jw-gMPZ4jAeM8BQx35NrCEHF15pI0T3VTvSTb1-dN9bhNnGZzAoLzsgUDllnM0WS57ayQOQMhFWpsSwVGFwqh5K01hUBumJYMUEJmSsyW5P4v6xBxtw9uhHDanV_IfgABSlXM
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ICETECT.2011.5760127
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Xplore: IEL
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1424479266
9781424479269
1424479258
9781424479252
EndPage 273
ExternalDocumentID 5760127
Genre orig-research
GroupedDBID 6IE
6IF
6IK
6IL
6IN
AAJGR
AAWTH
ADFMO
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
IEGSK
IERZE
OCL
RIE
RIL
ID FETCH-LOGICAL-i90t-a2118bacaf0fe5ec35fdf2450a246e9eb86ac976ea81bfc72e1c0940ae4a3c8e3
IEDL.DBID RIE
ISBN 1424479231
9781424479238
IngestDate Wed Aug 27 02:48:39 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-a2118bacaf0fe5ec35fdf2450a246e9eb86ac976ea81bfc72e1c0940ae4a3c8e3
PageCount 6
ParticipantIDs ieee_primary_5760127
PublicationCentury 2000
PublicationDate 2011-March
PublicationDateYYYYMMDD 2011-03-01
PublicationDate_xml – month: 03
  year: 2011
  text: 2011-March
PublicationDecade 2010
PublicationTitle 2011 International Conference on Emerging Trends in Electrical and Computer Technology
PublicationTitleAbbrev ICETECT
PublicationYear 2011
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0000669299
Score 1.5090822
Snippet This paper presents the modeling and simulation of a dynamic voltage restorer as a voltage sag/swell mitigation device in electrical power distribution...
SourceID ieee
SourceType Publisher
StartPage 268
SubjectTerms Dynamic Voltage Restorer (DVR)
Impedance
Inverters
Power quality
Power system dynamics
Pulse Width Modulation (PWM)
Switches
Total Harmonic Distortion (THD)
Voltage control
Voltage fluctuations
Z-Source inverter (ZSI)
Title Voltage sag/swell compensation using Z-Source inverter based dynamic voltage restorer
URI https://ieeexplore.ieee.org/document/5760127
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwGA3bTp5UNvE3OXi0W5umXXsuG1OYCHYyvIwvydcxlE66zoN_vfnabqJ48Nb2EEICffle3nsfYzeeGoKFSeVYPPApVDt2olBrB6JMUvq5yEIyOE8fwslM3s-DeYvd7r0wiFiJz7BPj9VdvlnrLVFltngP6aa0zdq2cKu9Wns-xUKnRfp4592iWDxvF-nUvEeNdc5z48FdMkpHSVpneDbj_miwUuHL-JBNdzOrZSWv_W2p-vrzV2jjf6d-xHrfTj7-uMeoY9bCvMtmz-u30v5H-AaWgw2xd5yU5bagrbaJkxZ-yV-cp4rY56ucejZjwQnxDDd1D3v-0QxSVL1psOixdDxKk4nTtFdwVrFbOmBLv0iBhszNMEDtB5nJhAxcEDLEGFUUgraHFQR7ss30UKCnKWwPUIKvI_RPWCdf53jKOAxRg8JAK2GkBAPCCB376LtoQApxxrq0Iov3OkBj0SzG-d-fL9hBTdyS0OuSdcpii1cW-Ut1XW35F4YHrJM
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NT8JAEN0gHvSkBozf7sGjhXa7Le2ZQECBmFgM8UJmt1NiNMWU4sFf705bMBoP3toeJpvdpG9m9r03jN04qgMGJpVl8MAlU-3QCnytLQgSSe7nIvFJ4Dye-IOpvJt5sxq73WphELEgn2GLHou7_Hip19QqM8W7TzelO2zXo6ilWmvbUTHgabA-3Ki3yBjP2Zg6Ve9BJZ5z7LA97PaiXjcqXTyryD9GrBQI0z9g483aSmLJa2udq5b-_GXb-N_FH7Lmt5aPP2xR6ojVMG2w6dPyLTd_Er6CRXtF_TtO3HJT0hYHxYkNv-DP1mPR2ucvKU1txowT5sU8LqfY848qSFZMp8GsyaJ-L-oOrGrAgvUS2rkFpvgLFGhI7AQ91K6XxImQng1C-hiiCnzQJl1BMLltojsCHU12e4ASXB2ge8zq6TLFE8ahgxoUelqJWEqIQcRChy66NsYghThlDdqR-XtpoTGvNuPs78_XbG8QjUfz0XByf872yzYu0b4uWD3P1nhp8oBcXRXH_wXFOK_j
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2011+International+Conference+on+Emerging+Trends+in+Electrical+and+Computer+Technology&rft.atitle=Voltage+sag%2Fswell+compensation+using+Z-Source+inverter+based+dynamic+voltage+restorer&rft.au=Usha%2C+R+P&rft.au=Rajkumar%2C+M&rft.au=Reddy%2C+S+R&rft.date=2011-03-01&rft.pub=IEEE&rft.isbn=9781424479238&rft.spage=268&rft.epage=273&rft_id=info:doi/10.1109%2FICETECT.2011.5760127&rft.externalDocID=5760127
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424479238/lc.gif&client=summon&freeimage=true
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424479238/mc.gif&client=summon&freeimage=true
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424479238/sc.gif&client=summon&freeimage=true