A real-time pulse wave detection device basing on signal envelope
We design a portable ECG (electrocardiograph) and PPG (photoplethysmograph pulse wave) measurement device which can simultaneously detect ECG and PPG signal, analyze arrhythmia and calculate SpO2 (oxygen saturation of blood). It consists of two parts: the main and the sub. MSP430 MCU is the most imp...
Saved in:
Published in | 2012 5th International Conference on Biomedical Engineering and Informatics pp. 812 - 816 |
---|---|
Main Author | |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.10.2012
|
Subjects | |
Online Access | Get full text |
ISBN | 9781467311830 1467311839 |
DOI | 10.1109/BMEI.2012.6513187 |
Cover
Loading…
Abstract | We design a portable ECG (electrocardiograph) and PPG (photoplethysmograph pulse wave) measurement device which can simultaneously detect ECG and PPG signal, analyze arrhythmia and calculate SpO2 (oxygen saturation of blood). It consists of two parts: the main and the sub. MSP430 MCU is the most important part. Besides, there are front-end amplifiers, filter circuit, Bluetooth module, data management module, keyboard and LCD display module, etc. The device can detect QRS complex and PPG signals in real time. For the Fantasia database and patients, the monitor can correctly judge the QRS complex of ECG signals and pulse wave signal. |
---|---|
AbstractList | We design a portable ECG (electrocardiograph) and PPG (photoplethysmograph pulse wave) measurement device which can simultaneously detect ECG and PPG signal, analyze arrhythmia and calculate SpO2 (oxygen saturation of blood). It consists of two parts: the main and the sub. MSP430 MCU is the most important part. Besides, there are front-end amplifiers, filter circuit, Bluetooth module, data management module, keyboard and LCD display module, etc. The device can detect QRS complex and PPG signals in real time. For the Fantasia database and patients, the monitor can correctly judge the QRS complex of ECG signals and pulse wave signal. |
Author | Ming Hong |
Author_xml | – sequence: 1 surname: Ming Hong fullname: Ming Hong organization: Inf. Eng. Inst., Wuhan Univ. of Technol., Wuhan, China |
BookMark | eNo1j81Kw0AUhUdU0NY8gLiZF0i9d2Y6P8tYWi1U3HRfppM7ZSRNQhIjvr0B6-r8wHfgzNhN3dTE2CPCAhHc88v7ersQgGKhlyjRmis2Q6WNRLTKXLPMGfufJdyxrO8_AWBi9YTfs6LgHfkqH9KZePtV9cS__Ui8pIHCkJp6cmMKxI--T_WJT0WfTrWvONUjVU1LD-w2-onLLjpn-816v3rLdx-v21Wxy5ODIbcqYlQgfBQQo1DBlx6FIyGEAYeknSEpQWinAkgbll4rZ7UqjyaqoIOcs6e_2UREh7ZLZ9_9HC6n5S83EEtC |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/BMEI.2012.6513187 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Xplore IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 1467311847 1467311820 9781467311847 9781467311823 |
EndPage | 816 |
ExternalDocumentID | 6513187 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IK 6IL 6IN AAJGR AAWTH ADFMO ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK IEGSK IERZE OCL RIE RIL |
ID | FETCH-LOGICAL-i90t-84f1f402af20ff24cada129e2227091e697e3302694c038c5a649864db7f4c6c3 |
IEDL.DBID | RIE |
ISBN | 9781467311830 1467311839 |
IngestDate | Wed Aug 27 04:33:23 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i90t-84f1f402af20ff24cada129e2227091e697e3302694c038c5a649864db7f4c6c3 |
PageCount | 5 |
ParticipantIDs | ieee_primary_6513187 |
PublicationCentury | 2000 |
PublicationDate | 2012-Oct. |
PublicationDateYYYYMMDD | 2012-10-01 |
PublicationDate_xml | – month: 10 year: 2012 text: 2012-Oct. |
PublicationDecade | 2010 |
PublicationTitle | 2012 5th International Conference on Biomedical Engineering and Informatics |
PublicationTitleAbbrev | BMEI |
PublicationYear | 2012 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0001106109 |
Score | 1.5039982 |
Snippet | We design a portable ECG (electrocardiograph) and PPG (photoplethysmograph pulse wave) measurement device which can simultaneously detect ECG and PPG signal,... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 812 |
SubjectTerms | ECG envelope PPG real-time |
Title | A real-time pulse wave detection device basing on signal envelope |
URI | https://ieeexplore.ieee.org/document/6513187 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA7bTp5UNvE3OXg0Xdukv45TNqYw8TBht5GkLyCObkir4F_ve223oXjwloakJCTkey_5vvcYuzGUOxbNBKFz6wuVahBGGi1SbJ6bIDI2IDXy7CmevqjHRbTosNudFgYAavIZeFSs3_Lzta3oqmwYRwFuwaTLuui4NVqt_X0K-TZ-Vmu34kQGhPzbkE7t9_ZVE5sN72bjByJ2hV770x_ZVWpwmRyy2XZYDafkzatK49mvXxEb_zvuIzbYy_j48w6gjlkHij4bjTjaiStBSeX5pkJk5J_6A3gOZc3KKrBEpwdHfMNeHCuI46FXHIqaXwQDNp-M5_dT0eZREK-ZX4pUucChm6hd6DsXKqtzjSgPpIJFawHiLAEpfZK0Wl-mNtKxoqDtuUmcsrGVJ6xXrAs4ZRxSB2me2thXWhmJrqHNwkijjwLOOufOWJ9mv9w0kTKW7cTP_66-YAe0Ag017pL1yvcKrhDiS3Ndr-03kzyibQ |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LSwMxEA61HvSk0opvc_Botvt-HKtYWu0WDxV6K0l2AmLZFtlV8Nc7s7ttUTx4y4ZkSUjIN5N83wxjN4pyx6KZIGSmbeHHEoTylBQxNs-UEyjtkBo5nYTDF_9xFsxa7HajhQGAinwGFhWrt_xsqUu6KuuFgYNbMNphuwGJcWu11vZGhbwbO6nUW2HkOYT966BOzff6XROb9e7ShxFRu1yr-e2P_CoVvAwOWLoeWM0qebPKQln661fMxv-O_JB1t0I-_ryBqCPWgrzD-n2OluJCUFp5vioRG_mn_ACeQVHxsnIs0fnBEeGwF8cKYnnIBYe8YhhBl00HD9P7oWgyKYjXxC5E7BvHoKMojWsb4_paZhJxHkgHi_YChEkEnmeTqFXbXqwDGfoUtj1TkfF1qL1j1s6XOZwwDrGBOIt1aPvSVx46hzpxA4leChhtjDllHZr9fFXHypg3Ez_7u_qa7Q2n6Xg-Hk2eztk-rUZNlLtg7eK9hEsE_EJdVev8DULwpbU |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2012+5th+International+Conference+on+Biomedical+Engineering+and+Informatics&rft.atitle=A+real-time+pulse+wave+detection+device+basing+on+signal+envelope&rft.au=Ming+Hong&rft.date=2012-10-01&rft.pub=IEEE&rft.isbn=9781467311830&rft.spage=812&rft.epage=816&rft_id=info:doi/10.1109%2FBMEI.2012.6513187&rft.externalDocID=6513187 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781467311830/lc.gif&client=summon&freeimage=true |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781467311830/mc.gif&client=summon&freeimage=true |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781467311830/sc.gif&client=summon&freeimage=true |