Three level hysteresis current controller based active power filter for harmonic compensation

This paper present three-phase four-wire active filter for power line conditioning (PLC) to improve power quality in the distribution network. The active power filter (APF) is implemented with PWM based current controlled voltage source inverter (VSI). This VSI switching signals are generated throug...

Full description

Saved in:
Bibliographic Details
Published in2011 International Conference on Emerging Trends in Electrical and Computer Technology pp. 407 - 412
Main Authors Karuppanan, P, Ram, Saswat Kumar, Mahapatra, KamalaKanta
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.03.2011
Subjects
Online AccessGet full text
ISBN1424479231
9781424479238
DOI10.1109/ICETECT.2011.5760151

Cover

Loading…
Abstract This paper present three-phase four-wire active filter for power line conditioning (PLC) to improve power quality in the distribution network. The active power filter (APF) is implemented with PWM based current controlled voltage source inverter (VSI). This VSI switching signals are generated through proposed three-level hysteresis current controller (HCC) that achieves significant reduction in the magnitude and variation of the switching frequency; it is indicating improved performance compared to 2-level HCC. The shunt APLC system is modeled and investigated under different unbalanced non-linear load conditions using Matlab programs. The simulation results reveal that the active power filter is effectively compensating the current harmonics and reactive power at point of common coupling. The active power line conditioner system is in compliance with IEEE 519 and IEC 61000-3 recommended harmonic standards.
AbstractList This paper present three-phase four-wire active filter for power line conditioning (PLC) to improve power quality in the distribution network. The active power filter (APF) is implemented with PWM based current controlled voltage source inverter (VSI). This VSI switching signals are generated through proposed three-level hysteresis current controller (HCC) that achieves significant reduction in the magnitude and variation of the switching frequency; it is indicating improved performance compared to 2-level HCC. The shunt APLC system is modeled and investigated under different unbalanced non-linear load conditions using Matlab programs. The simulation results reveal that the active power filter is effectively compensating the current harmonics and reactive power at point of common coupling. The active power line conditioner system is in compliance with IEEE 519 and IEC 61000-3 recommended harmonic standards.
Author Ram, Saswat Kumar
Mahapatra, KamalaKanta
Karuppanan, P
Author_xml – sequence: 1
  givenname: P
  surname: Karuppanan
  fullname: Karuppanan, P
  email: karuppanan1982@gmail.com
  organization: Dept of Electron. & Commun. Eng., Nat. Inst. of Technol., Rourkela, India
– sequence: 2
  givenname: Saswat Kumar
  surname: Ram
  fullname: Ram, Saswat Kumar
  email: saswatram01@gmail.com
  organization: Dept of Electron. & Commun. Eng., Nat. Inst. of Technol., Rourkela, India
– sequence: 3
  givenname: KamalaKanta
  surname: Mahapatra
  fullname: Mahapatra, KamalaKanta
  email: kkm@nitrkl.ac.in
  organization: Dept of Electron. & Commun. Eng., Nat. Inst. of Technol., Rourkela, India
BookMark eNpFkMFKAzEYhCMqaGufQA95gdb8STZpjrLUWih42auU7O6_NLKbLEms9O1dseBchvlg5jAzcuODR0KegK0AmHnelZtqU1YrzgBWhVYMCrgiM5BcSm24Utf_QcAdWaT0ySYpZbgx9-SjOkZE2uMJe3o8p4wRk0u0-YoRfaZN8DmGvsdIa5uwpbbJ7oR0DN8T6lyffy1EerRxCN41U2MY0SebXfAP5LazfcLFxeeket1U5dty_77dlS_7pTMsL9egBAPd1LVcNxw6WQjN2hrVGnRddKIT0NZKTgw5b1kHWoMpDIq2tSiFFXPy-DfrEPEwRjfYeD5c3hA_A0dXxg
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/ICETECT.2011.5760151
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1424479266
9781424479269
1424479258
9781424479252
EndPage 412
ExternalDocumentID 5760151
Genre orig-research
GroupedDBID 6IE
6IF
6IK
6IL
6IN
AAJGR
AAWTH
ADFMO
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
IEGSK
IERZE
OCL
RIE
RIL
ID FETCH-LOGICAL-i90t-8163017cbb48c21f45370dbe6817b5f3f31db6470de22d0f1771959e3ddae43a3
IEDL.DBID RIE
ISBN 1424479231
9781424479238
IngestDate Wed Aug 27 02:48:39 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-8163017cbb48c21f45370dbe6817b5f3f31db6470de22d0f1771959e3ddae43a3
PageCount 6
ParticipantIDs ieee_primary_5760151
PublicationCentury 2000
PublicationDate 2011-March
PublicationDateYYYYMMDD 2011-03-01
PublicationDate_xml – month: 03
  year: 2011
  text: 2011-March
PublicationDecade 2010
PublicationTitle 2011 International Conference on Emerging Trends in Electrical and Computer Technology
PublicationTitleAbbrev ICETECT
PublicationYear 2011
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0000669299
Score 1.5092511
Snippet This paper present three-phase four-wire active filter for power line conditioning (PLC) to improve power quality in the distribution network. The active power...
SourceID ieee
SourceType Publisher
StartPage 407
SubjectTerms 3-level Hysteresis Current Controller (HCC)
Active filters
Active Power Line Conditioners (APLC)
Harmonic analysis
Harmonics
Hysteresis
Inverters
PI-Controller
Power harmonic filters
Power quality
Switches
Title Three level hysteresis current controller based active power filter for harmonic compensation
URI https://ieeexplore.ieee.org/document/5760151
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEF5qT55UWvHNHjyamtcmm3NpqULFQ4RepOxjFoulLTW5-Oud2aQVxYO3ZCFh2WF3Hvt93zB2q4i_WWQicHHmqIUZBNI4CFJpBPp_ZYRnvU-fsslL-jgTsw6723NhAMCDz2BAj_4u365NTaUyTN4xfSC-9AEmbg1Xa19PQdeJnr7YcbdIFi_aSTq177KlzkVhcf8wHJWjYdloeLb__dFgxfuX8RGb7mbWwEreB3WlB-bzl2jjf6d-zPrfTD7-vPdRJ6wDqx57LdGAwJeEF-JvJOWMOffig5tGq4m38PUlbDk5OcuVPxT5hjqqcbegC3aOwS4n2WuS1uUETMd82Fu5z8rxqBxOgrbNQrAowiqQGJHhtjRao33iyKUiyUOrIZNRroVLXBJZnaU4BnFsQxflOQnSQGKtgjRRySnrrtYrOGNcOpVGBiNAosdKrRSmX86IQuKpgJ_ac9ajlZlvGiGNebsoF38PX7LDpoBLgK8r1q22NVxjBFDpG2_6Lzs-rXg
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NT8JAEN0QPOhJDRi_3YNHi922227PBAIKxENNuBiyn5FogGC5-Oud2RaMxoO3dpM2m51238zsvDeE3Erkb-YpD1yUOmxhZgOhnQ0SoTngv9Tcs97Hk3TwnDxM-bRB7nZcGGutLz6zHbz0Z_lmqTeYKoPgHcIH5EvvAe5zVrG1dhkVAE_A-nzL3kJhPLYVdarvRU2eY2F-P-z2il63qFQ86zf_aLHiEaZ_SMbbuVWFJW-dTak6-vOXbON_J39E2t9cPvq0Q6lj0rCLFnkpwISWvmPFEH1FMWeIuucfVFdqTbQuYH-3a4owZ6j02yJdYU816uZ4xE7B3aUofI3iuhRL0yEi9nZuk6LfK7qDoG60EMzzsAwE-GTwY2qlwEIRcwmPs9AomwqWKe5iFzOj0gTGbBSZ0LEsQ0kaGxsjbRLL-IQ0F8uFPSVUOJkwDT4gEmSFkhICMKd5LmBfgEfNGWnhysxWlZTGrF6U87-Hb8j-oBiPZqPh5PGCHFTpXCz_uiTNcr2xV-APlOrafwZfeoiwwQ
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2011+International+Conference+on+Emerging+Trends+in+Electrical+and+Computer+Technology&rft.atitle=Three+level+hysteresis+current+controller+based+active+power+filter+for+harmonic+compensation&rft.au=Karuppanan%2C+P&rft.au=Ram%2C+Saswat+Kumar&rft.au=Mahapatra%2C+KamalaKanta&rft.date=2011-03-01&rft.pub=IEEE&rft.isbn=9781424479238&rft.spage=407&rft.epage=412&rft_id=info:doi/10.1109%2FICETECT.2011.5760151&rft.externalDocID=5760151
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424479238/lc.gif&client=summon&freeimage=true
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424479238/mc.gif&client=summon&freeimage=true
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781424479238/sc.gif&client=summon&freeimage=true