Non-contact acquisition of respiration and heart rates using Doppler radar with time domain peak-detection algorithm
The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare monitoring, due to the extremely low burden on patients, unconsciousness and unconstraint. Most of the previous studies have performed the f...
Saved in:
Published in | Conference proceedings (IEEE Engineering in Medicine and Biology Society. Conf.) Vol. 2017; pp. 2847 - 2850 |
---|---|
Main Authors | , , |
Format | Conference Proceeding Journal Article |
Language | English |
Published |
United States
IEEE
01.07.2017
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare monitoring, due to the extremely low burden on patients, unconsciousness and unconstraint. Most of the previous studies have performed the frequency-domain analysis of radar signals to detect the respiration and heartbeat frequency. However, these procedures required long period time (approximately 30 s) windows to obtain a high-resolution spectrum. In this study, we propose a time-domain peak detection algorithm for the fast acquisition of the RR and HR within a breathing cycle (approximately 5 s), including inhalation and exhalation. Signal pre-processing using an analog band-pass filter (BPF) that extracts respiration and heartbeat signals was performed. Thereafter, the HR and RR were calculated using a peak position detection method, which was carried out via LABVIEW. To evaluate the measurement accuracy, we measured the HR and RR of seven subjects in the laboratory. As a reference of HR and RR, the persons wore contact sensors i.e., an electrocardiograph (ECG) and a respiration band. The time domain peak-detection algorithm, based on the Doppler radar, exhibited a significant correlation coefficient of HR of 0.92 and a correlation coefficient of RR of 0.99, between the ECG and respiration band, respectively. |
---|---|
AbstractList | The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare monitoring, due to the extremely low burden on patients, unconsciousness and unconstraint. Most of the previous studies have performed the frequency-domain analysis of radar signals to detect the respiration and heartbeat frequency. However, these procedures required long period time (approximately 30 s) windows to obtain a high-resolution spectrum. In this study, we propose a time-domain peak detection algorithm for the fast acquisition of the RR and HR within a breathing cycle (approximately 5 s), including inhalation and exhalation. Signal pre-processing using an analog band-pass filter (BPF) that extracts respiration and heartbeat signals was performed. Thereafter, the HR and RR were calculated using a peak position detection method, which was carried out via LABVIEW. To evaluate the measurement accuracy, we measured the HR and RR of seven subjects in the laboratory. As a reference of HR and RR, the persons wore contact sensors i.e., an electrocardiograph (ECG) and a respiration band. The time domain peak-detection algorithm, based on the Doppler radar, exhibited a significant correlation coefficient of HR of 0.92 and a correlation coefficient of RR of 0.99, between the ECG and respiration band, respectively. |
Author | Ishibashi, Koichiro Xiaofeng Yang Guanghao Sun |
Author_xml | – sequence: 1 surname: Xiaofeng Yang fullname: Xiaofeng Yang email: feng022026@gmail.com organization: Grad. Sch. of Inf. & Eng., Univ. of Electro-Commun., Chofu, Japan – sequence: 2 surname: Guanghao Sun fullname: Guanghao Sun organization: Grad. Sch. of Inf. & Eng., Univ. of Electro-Commun., Chofu, Japan – sequence: 3 givenname: Koichiro surname: Ishibashi fullname: Ishibashi, Koichiro organization: Grad. Sch. of Inf. & Eng., Univ. of Electro-Commun., Chofu, Japan |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/29060491$$D View this record in MEDLINE/PubMed |
BookMark | eNo9kM1OwzAQhI1URH_oAyAk5BdIWSd2HB-hlB-pwAUkbpVjb1pD4wTHFeLtiWjhtJqZTyPtjMnANx4JOWMwYwzU5eLxej5LgclZAZnkAo7IVMmCCVCQFqDSARkxIWTCJLwNybjr3gFylnN2Qoapghy4YiMSnxqfmMZHbSLV5nPnOhdd42lT0YBd64L-ldpbukEdIu0N7Oiuc35Nb5q23WLoPasD_XJxQ6Orkdqm1s7TFvVHYjGi2Xds103omfqUHFd62-H0cCfk9XbxMr9Pls93D_OrZeLSjMXEiErawvBclFhw0GXVK5lZYQrZB5pn1gosQaRgpIZKVVxzC1aqymbC6mxCLva97a6s0a7a4Godvld_7_fA-R5wiPgfHwbNfgAwR2vl |
ContentType | Conference Proceeding Journal Article |
DBID | 6IE 6IH CBEJK RIE RIO NPM |
DOI | 10.1109/EMBC.2017.8037450 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEL IEEE Proceedings Order Plans (POP) 1998-present PubMed |
DatabaseTitle | PubMed |
DatabaseTitleList | PubMed |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: RIE name: IEL url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISBN | 9781509028092 1509028099 |
EndPage | 2850 |
ExternalDocumentID | 29060491 8037450 |
Genre | orig-research Research Support, Non-U.S. Gov't Journal Article |
GroupedDBID | 29F 29G 6IE 6IH 6IK 6IM ACGFS ALMA_UNASSIGNED_HOLDINGS CBEJK IPLJI M43 RIE RIO RNS NPM |
ID | FETCH-LOGICAL-i231t-c5f7d8c465be840abfd8c73d5c877d8a43dd5eb0520c7a0f9f4a4d0d79fd35da3 |
IEDL.DBID | RIE |
ISSN | 1557-170X |
IngestDate | Wed Feb 19 02:42:37 EST 2025 Wed Aug 27 02:58:43 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i231t-c5f7d8c465be840abfd8c73d5c877d8a43dd5eb0520c7a0f9f4a4d0d79fd35da3 |
PMID | 29060491 |
PageCount | 4 |
ParticipantIDs | pubmed_primary_29060491 ieee_primary_8037450 |
PublicationCentury | 2000 |
PublicationDate | 2017-07-00 |
PublicationDateYYYYMMDD | 2017-07-01 |
PublicationDate_xml | – month: 07 year: 2017 text: 2017-07-00 |
PublicationDecade | 2010 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Conference proceedings (IEEE Engineering in Medicine and Biology Society. Conf.) |
PublicationTitleAbbrev | EMBC |
PublicationTitleAlternate | Conf Proc IEEE Eng Med Biol Soc |
PublicationYear | 2017 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0061641 |
Score | 1.9036299 |
Snippet | The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare... |
SourceID | pubmed ieee |
SourceType | Index Database Publisher |
StartPage | 2847 |
SubjectTerms | Band-pass filters Correlation coefficient Detection algorithms Doppler radar Heart beat |
Title | Non-contact acquisition of respiration and heart rates using Doppler radar with time domain peak-detection algorithm |
URI | https://ieeexplore.ieee.org/document/8037450 https://www.ncbi.nlm.nih.gov/pubmed/29060491 |
Volume | 2017 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELYKEyw8Wt4gD4y4TYhdNysvIaQiBip1q872paqABIK78OvxJWlBFQNbHCeW5Yvi73zffcfYuYY4TjNwAmIEIa2JhbmEVCAJk2jE4HRQovDwsX8_kg9jNW6xi2UuDCJW5DPs0mUVy3eFndNRWW9AYinkoK8Fx63O1Vr8dfsB9tfaqIpED6NxE8GMo7R3O7y6JhKX7jYDkAJwSqoxpMxZFVVZAZXV5nK3xYaLadWckpfu3Juu_VpRbPzvvLdZ5yeNjz8tN6gd1sJ8l23-UiBsM_9Y5ILo6mA9B_sxn9UcLl5kvGyi8NSE3HGqfe05SUt8cqLLT_lNETAsluGeg5LTkS6nWvXcFW8wy_k7wotw6Cu2VxjjdVqU4Zm3Dhvd3T5f34umEIOYBfjnhVWZdgMr-8pgcAjBZKGlE6fsQIcOkIlzCg1RaqyGKEszCdJFTqeZS5SDZI-t50WOB4wbktsfUN6StFJJmyJKh1kAJVaBkfqQtWn9Ju-11sakWbpDtl_bZ9mxMODR3y8csw2yeE2sPWHrvpzjaYAP3pxV38037RnEgg |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELYqGICFR8v74YERl4badbNSQAXaigGkbtXZvqCqNIGQLvx6fElaUMXAFseJZfmi3Gffd98xdq4hCMIInIAAQUhrAmGuIBRIwiQa0W86KFG4P2h1X-TDUA0r7GKRC4OIOfkM63SZx_JdYmd0VHbZJrEU2qCver-vgiJba_7fbXngX6ijKpI9bAzLGGbQCC9v-9cdonHpejkEaQCHpBtD2px5WZUlWJm7l7tN1p9PrGCVTOqzzNTt15Jm439nvsVqP4l8_GnhorZZBeMdtvFLg7DKskESCyKsg8042I_ZuGBx8STiaRmHpybEjlP164yTuMQnJ8L8K79JPIrF1N9zkHI61OVUrZ67ZArjmL8jTITDLOd7-THeXpPUPzOtsZe72-dOV5SlGMTYA8BMWBVp17aypQz6LSGYyLd00ynb1r4DZNM5hYZINVZDIwojCdI1nA4j11QOmrtsJU5i3GfckOB-mzKXpJVK2hBROow8LLEKjNQHrErrN3ov1DZG5dIdsL3CPouOuQEP_37hjK11n_u9Ue9-8HjE1sn6Bc32mK1k6QxPPJjIzGn-DX0DWMLHyw |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=Conference+proceedings+%28IEEE+Engineering+in+Medicine+and+Biology+Society.+Conf.%29&rft.atitle=Non-contact+acquisition+of+respiration+and+heart+rates+using+Doppler+radar+with+time+domain+peak-detection+algorithm&rft.au=Xiaofeng+Yang&rft.au=Guanghao+Sun&rft.au=Ishibashi%2C+Koichiro&rft.date=2017-07-01&rft.pub=IEEE&rft.issn=1557-170X&rft.spage=2847&rft.epage=2850&rft_id=info:doi/10.1109%2FEMBC.2017.8037450&rft_id=info%3Apmid%2F29060491&rft.externalDocID=8037450 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1557-170X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1557-170X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1557-170X&client=summon |