The Radiation Effect on the Parameters of Reference Voltage Sources and Charge-Sensitive Amplifiers of the Structured Array MH2XA010
Theeffect of 6 MeV fast electrons and {}^{60}{\mathbf{Co}} gamma radiation on the parameters of analog components of the structured array (SA) MH2XA010 - the reference voltage source (RVS) and the charge-sensitive amplifier (CSA) is compared. It is shown that at the absorbed dose of gamma radiation...
Saved in:
Published in | 2018 18th European Conference on Radiation and Its Effects on Components and Systems (RADECS) pp. 1 - 5 |
---|---|
Main Authors | , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.09.2018
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Theeffect of 6 MeV fast electrons and {}^{60}{\mathbf{Co}} gamma radiation on the parameters of analog components of the structured array (SA) MH2XA010 - the reference voltage source (RVS) and the charge-sensitive amplifier (CSA) is compared. It is shown that at the absorbed dose of gamma radiation \mathbf{D}_{\mathbf{G}} = 2.04 Mrad and the electron fluence 3.0×10 14 el/cm 2 the change in the RVS and CSA parameters doesn't exceed the norms established for the operating temperature range. SA MH2XA010 is recommended for the fabrication of analog sensor interfaces operating under hard operation conditions. |
---|---|
ISSN: | 1609-0438 |
DOI: | 10.1109/RADECS45761.2018.9328653 |