Influence of Traveling Wave Detection Sensitivity on Transient Pattern Recognition-Based Single-Ended Fault Location Approach
In electrical power systems, transmission line fault location has been a widely investigated topic. Among the existing fault location methods, traveling wave (TW)-based solutions have shown to be the most accurate alternative. As a result, the development and evaluation of single-ended TW fault loca...
Saved in:
Published in | 2019 Workshop on Communication Networks and Power Systems (WCNPS) pp. 1 - 5 |
---|---|
Main Authors | , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.10.2019
|
Subjects | |
Online Access | Get full text |
DOI | 10.1109/WCNPS.2019.8896342 |
Cover
Loading…
Abstract | In electrical power systems, transmission line fault location has been a widely investigated topic. Among the existing fault location methods, traveling wave (TW)-based solutions have shown to be the most accurate alternative. As a result, the development and evaluation of single-ended TW fault location (SETWFL) methods have attracted the interest of utilities, mainly due to its reduced cost and ease of application. In this context, although a commercially available SETWFL solution based on the recognition of fault-induced transient patterns has shown to be promising, further studies on how the sensitivity of TW detectors influence the method's performance are still required. Thus, this paper evaluates the relay transient detection sensitivity when applying a commercially available SETWFL function. |
---|---|
AbstractList | In electrical power systems, transmission line fault location has been a widely investigated topic. Among the existing fault location methods, traveling wave (TW)-based solutions have shown to be the most accurate alternative. As a result, the development and evaluation of single-ended TW fault location (SETWFL) methods have attracted the interest of utilities, mainly due to its reduced cost and ease of application. In this context, although a commercially available SETWFL solution based on the recognition of fault-induced transient patterns has shown to be promising, further studies on how the sensitivity of TW detectors influence the method's performance are still required. Thus, this paper evaluates the relay transient detection sensitivity when applying a commercially available SETWFL function. |
Author | da Cunha, Gustavo Abreu da Rocha Honorato, Tiago Lopes, Felipe Vigolvino |
Author_xml | – sequence: 1 givenname: Gustavo Abreu surname: da Cunha fullname: da Cunha, Gustavo Abreu organization: University of Brasília,Department of Electrical Engineering,Brasília,Brazil – sequence: 2 givenname: Felipe Vigolvino surname: Lopes fullname: Lopes, Felipe Vigolvino organization: University of Brasília,Department of Electrical Engineering,Brasília,Brazil – sequence: 3 givenname: Tiago surname: da Rocha Honorato fullname: da Rocha Honorato, Tiago organization: University of Brasília,Department of Electrical Engineering,Brasília,Brazil |
BookMark | eNotkE1OwzAYRI0ECyi9AGx8gQT_JbGXJbSlUgQVidRl5ThfiqXgRIlbqQvujoGuZp40eou5Q9eud4DQAyUxpUQ97fK3bRkzQlUspUq5YFdorjJJMyYpU4yIW_S9cW13BGcA9y2uRn2CzroD3oWCX8CD8bZ3uAQ3WW9P1p9xwLALDM7jrfYeRoc_wPQHZ3_H0bOeoMFl0HQQLV0TYKWPncdFb_SfbjEMY6_N5z26aXU3wfySM1StllX-GhXv602-KCLLCPdRAgCUGJUmSqo6pZCBaDg3TCWCtEZKRkijRcobweuaZ8wokSWtaikoyASfocd_rQ2i_TDaLz2e95dP-A_D1lz- |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/WCNPS.2019.8896342 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
EISBN | 9781728129204 1728129206 |
EndPage | 5 |
ExternalDocumentID | 8896342 |
Genre | orig-research |
GroupedDBID | 6IE 6IL CBEJK RIE RIL |
ID | FETCH-LOGICAL-i203t-5eee10c965989b61e7e4d33c29540fc88200da463d43bb372c9475f9f1e9e743 |
IEDL.DBID | RIE |
IngestDate | Wed Aug 06 17:54:29 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i203t-5eee10c965989b61e7e4d33c29540fc88200da463d43bb372c9475f9f1e9e743 |
PageCount | 5 |
ParticipantIDs | ieee_primary_8896342 |
PublicationCentury | 2000 |
PublicationDate | 2019-Oct. |
PublicationDateYYYYMMDD | 2019-10-01 |
PublicationDate_xml | – month: 10 year: 2019 text: 2019-Oct. |
PublicationDecade | 2010 |
PublicationTitle | 2019 Workshop on Communication Networks and Power Systems (WCNPS) |
PublicationTitleAbbrev | WCNPS |
PublicationYear | 2019 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
Score | 1.7168721 |
Snippet | In electrical power systems, transmission line fault location has been a widely investigated topic. Among the existing fault location methods, traveling wave... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | Conferences Costs Detectors Fault location Pattern recognition Power systems Power transmission lines Relays Sensitivity SETWFL Transient analysis transient detection sensitivity transmission lines Traveling wave |
Title | Influence of Traveling Wave Detection Sensitivity on Transient Pattern Recognition-Based Single-Ended Fault Location Approach |
URI | https://ieeexplore.ieee.org/document/8896342 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA5zJ08qm_ibHDyaLU26tjnq3FBxY7jJdhtN8griaEXai-D_bl66TRQP3tIS-iOv5Etfvu97hFyi55bQ1jIRx5i6iYClQaqYlMpIlTnIMKgdHo2ju-fwYdFbNMjVVgsDAJ58Bh1s-r18W5gKU2XdJHGfS-gm3B3341ZrtTY6GK668_54MkWyFkbfd_xRMcUDxnCPjDa3qnkir52q1B3z8cuF8b_Psk_a39I8OtmCzgFpQN4in_ebUiO0yOgMKwqhypzOXYPeQunpVjmdIlm9rhZB3aGHKZRD0ok32czp04ZNVOTsxsGbpVN3mRWwAebJ6TCtViV9LOosH71e25G3yWw4mPXv2LquAnsRXJas514m4AatBBOlowBiCK2UBrf8eGbcmptzm4aRtKHUWsbCqDDuZSoLQIFbcRySZl7kcESom510YHhgReT6J1onobU6SqwQHIQyx6SFI7d8q50zlutBO_n79CnZxejVVLkz0izfKzh3kF_qCx_rL4A7r68 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NS8MwGA5jHvSksonf5uDRbmnSrxx1bmy6jeEq2200HwVxtCLtRfC_mzddJ4oHb2kJbZO35Alvnud5EboGzy0qlHJoGELqJtBO4ibcYYxLxlMDGRK0w5NpMHz2Hpb-soFutloYrbUln-kONO1ZvsplCamybhSZ38UzC-6OwX3frdRatRKG8O6iN53Nga4F8bddf9RMsZAx2EeT-mUVU-S1UxaiIz9--TD-92sOUPtbnIdnW9g5RA2dtdDnqC42gvMUx1BTCHTmeGEa-F4XlnCV4TnQ1at6EdhcWqACQSSeWZvNDD_VfKI8c-4MwCk8N49Za6cPmXI8SMp1gcd5lefDtxtD8jaKB_24N3Q2lRWcF0pY4fhmMC6RYCYYcRG4OtSeYkzCoR9Jpdl1E6ISL2DKY0KwkEruhX7KU1dzbfYcR6iZ5Zk-RtisT8KVxFU0MP0jISJPKRFEilKiKZcnqAUzt3qrvDNWm0k7_fv2FdodxpPxajyaPp6hPYhkRZw7R83ivdQXZgNQiEsb9y_UPLL4 |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2019+Workshop+on+Communication+Networks+and+Power+Systems+%28WCNPS%29&rft.atitle=Influence+of+Traveling+Wave+Detection+Sensitivity+on+Transient+Pattern+Recognition-Based+Single-Ended+Fault+Location+Approach&rft.au=da+Cunha%2C+Gustavo+Abreu&rft.au=Lopes%2C+Felipe+Vigolvino&rft.au=da+Rocha+Honorato%2C+Tiago&rft.date=2019-10-01&rft.pub=IEEE&rft.spage=1&rft.epage=5&rft_id=info:doi/10.1109%2FWCNPS.2019.8896342&rft.externalDocID=8896342 |