Power Transformer Condition Evaluation by the Analysis of DGA Methods
Power transformer condition evaluation by the analysis of insulating oil is presented in this paper. Evaluating the condition of power transformer by means of Dissolved Gas Analysis (DGA) has been a famous approach for insulating oil analysis to find out incipient faults in transformers before catas...
Saved in:
Published in | 2012 Asia-Pacific Power and Energy Engineering Conference pp. 1 - 4 |
---|---|
Main Authors | , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.03.2012
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Power transformer condition evaluation by the analysis of insulating oil is presented in this paper. Evaluating the condition of power transformer by means of Dissolved Gas Analysis (DGA) has been a famous approach for insulating oil analysis to find out incipient faults in transformers before catastrophic damages occur. Diagnostic tests of power transformer are classified into five types: key gases, roger ratio, Doernenburg, IEC and Duval triangle methods. The study was further done to investigate the accuracy of each method in predicting the fault and the consistency of the methods. Then the result of this work is useful for planning an appropriate maintenance strategy to keep the power transformer in acceptable condition. |
---|---|
AbstractList | Power transformer condition evaluation by the analysis of insulating oil is presented in this paper. Evaluating the condition of power transformer by means of Dissolved Gas Analysis (DGA) has been a famous approach for insulating oil analysis to find out incipient faults in transformers before catastrophic damages occur. Diagnostic tests of power transformer are classified into five types: key gases, roger ratio, Doernenburg, IEC and Duval triangle methods. The study was further done to investigate the accuracy of each method in predicting the fault and the consistency of the methods. Then the result of this work is useful for planning an appropriate maintenance strategy to keep the power transformer in acceptable condition. |
Author | Haema, J. Phadungthin, R. |
Author_xml | – sequence: 1 givenname: J. surname: Haema fullname: Haema, J. email: iam.juthathiph@gmail.com organization: Dept. of Electr. Eng. Technol., King Mongkut's Univ. of Technol. North Bangkok, Bangkok, Thailand – sequence: 2 givenname: R. surname: Phadungthin fullname: Phadungthin, R. email: rattanakornp@kmutnb.ac.th organization: Dept. of Electr. Eng. Technol., King Mongkut's Univ. of Technol. North Bangkok, Bangkok, Thailand |
BookMark | eNpVkLFOwzAYhI0oEqXkCbr4BRL8x3bsjFEIBamIDGWunPi3GpTGKA6gvD1V6cIt951OuuHuyGLwAxKyBpYAsPyhqOuqKpOUQZpknCkJ7IpEudIgpFJMCpVe_8tSL8gyBalioXl-S6IQPthJOuU6hyWpav-DI92NZgjOj8cTl36w3dT5gVbfpv8yZ2xmOh2QFoPp59AF6h193BT0FaeDt-Ge3DjTB4wuviLvT9WufI63b5uXstjGHSg5xYht2wrNHCAo57TLOAoOWeOU1Ya3lkvphHAWbGqwyfDUGWUZZ7lsGEi-Iuu_3Q4R959jdzTjvL8cwX8B_TNRJA |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/APPEEC.2012.6307510 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library Online IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library Online url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISBN | 9781457705472 1457705478 145770546X 9781457705465 |
EndPage | 4 |
ExternalDocumentID | 6307510 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IL 6IN AAJGR ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK OCL RIE RIL |
ID | FETCH-LOGICAL-i175t-eeccc480f1e17ff8f63e4316bf7d8a3cd355f44fd1d2aeb6e316a7d03095b0153 |
IEDL.DBID | RIE |
ISBN | 9781457705458 1457705451 |
ISSN | 2157-4839 |
IngestDate | Wed Jun 26 19:24:20 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i175t-eeccc480f1e17ff8f63e4316bf7d8a3cd355f44fd1d2aeb6e316a7d03095b0153 |
PageCount | 4 |
ParticipantIDs | ieee_primary_6307510 |
PublicationCentury | 2000 |
PublicationDate | 2012-March |
PublicationDateYYYYMMDD | 2012-03-01 |
PublicationDate_xml | – month: 03 year: 2012 text: 2012-March |
PublicationDecade | 2010 |
PublicationTitle | 2012 Asia-Pacific Power and Energy Engineering Conference |
PublicationTitleAbbrev | APPEEC |
PublicationYear | 2012 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0000823891 ssj0003203524 |
Score | 1.5268176 |
Snippet | Power transformer condition evaluation by the analysis of insulating oil is presented in this paper. Evaluating the condition of power transformer by means of... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | Discharges (electric) Gases IEC Oil insulation Partial discharges Power transformer insulation |
Title | Power Transformer Condition Evaluation by the Analysis of DGA Methods |
URI | https://ieeexplore.ieee.org/document/6307510 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELZKJ1h4tIi3PDCStEns2BmrklIhFWVopW5VHNsSQmoRTQf49dw5Dx5iYLMd5WVbus93931HyK2IdBLmjvYLx1WmLfNyFjAvBnDPuUhgGInCs6d4umCPS77skLuWC2OMcclnxsemi-XrTbFDV9kghg3JkU-1J5Kk4mq1_hSMGMla9wX7UYhKnxhUBqMm0GeWOF4XFwJQCg8auae6L2tFomCYDEZZlqZjTPsK_fqVP2qvONMzOSSz5qOrjJMXf1cqv_j4pef43786Iv0vkh_NWvN1TDpmfUIOvukT9kiaYQ01Om_ALbThZu2yvGja6oRT9U4BR9JG4IRuLL1_GNGZq0697ZPFJJ2Pp15dd8F7BjBRegaWtWByaAMTCGuljSODjHllhZZ5VGjAKJYxqwMd5kbFBq7lQmOwhiuAF9Ep6a43a3NGqFQmZ7lWOoGTJAdwIENAQENRALKEZ-pz0sMJWb1W0hqrei4u_h6-JPu4KFUK2BXplm87cw2YoFQ3bjN8AqxsrIQ |
link.rule.ids | 310,311,783,787,792,793,799,27937,55086 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELaqMgALjxbxxgMjSZvEjp2xKikFmipDK3Wr4tiWEFKLIB3g13N2HjzEwGY7ysu2dJ_v7vsOoWsWyMjPLO0XjqtEauJkxCNOCOCeUhbBsCEKJ9NwPCcPC7pooZuGC6OUsslnyjVNG8uX63xjXGW9EDYkNXyqLcDVPCzZWo1HxcSMeKX8YvqBb7Q-TVgZzBozXrPIMrsoY4BTqFcLPlV9XmkSef2oN0jTOB6axC_frV76o_qKNT6jPZTUn13mnDy7m0K4-ccvRcf__tc-6n7R_HDaGLAD1FKrQ7T7TaGwg-LUVFHDsxreQhtuljbPC8eNUjgW7xiQJK4lTvBa49u7AU5sfeq3LpqP4tlw7FSVF5wngBOFo2Bhc8L72lMe05rrMFCGMy80kzwLcgkoRROipSf9TIlQwbWMSROuoQIARnCE2qv1Sh0jzIXKSCaFjOAsSQEecB8wUJ_lgC3hmfIEdcyELF9KcY1lNRenfw9foe3xLJksJ_fTxzO0YxaoTAg7R-3idaMuACEU4tJujE_pha_P |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2012+Asia-Pacific+Power+and+Energy+Engineering+Conference&rft.atitle=Power+Transformer+Condition+Evaluation+by+the+Analysis+of+DGA+Methods&rft.au=Haema%2C+J.&rft.au=Phadungthin%2C+R.&rft.date=2012-03-01&rft.pub=IEEE&rft.isbn=9781457705458&rft.issn=2157-4839&rft.spage=1&rft.epage=4&rft_id=info:doi/10.1109%2FAPPEEC.2012.6307510&rft.externalDocID=6307510 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2157-4839&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2157-4839&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2157-4839&client=summon |