Compact spiral antennas for MICS band wireless endoscope toward pediatric applications
Endoscopy is a medical procedure carrying out in-vivo tests. The conventional wired endoscopy process is pain staking and time consuming. An alternative to this wired one would be a wireless endoscope system. Various pill type endoscopes such as iPill, Sayaka, and Smart Pill have been developed for...
Saved in:
Published in | 2010 IEEE Antennas and Propagation Society International Symposium pp. 1 - 4 |
---|---|
Main Authors | , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.07.2010
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Endoscopy is a medical procedure carrying out in-vivo tests. The conventional wired endoscopy process is pain staking and time consuming. An alternative to this wired one would be a wireless endoscope system. Various pill type endoscopes such as iPill, Sayaka, and Smart Pill have been developed for drug delivery, imaging, and pH sensing in the stomach and intestines. The current device size of approximately 10 mm × 20 mm allows the usage of products only for a human adult as the average diameter of adult upper esophagus of approximately 13 mm is large enough to accommodate such devices while they are too big for children. To extend the usage of such wireless endoscopy to pediatric applications, pill should be greatly reduced in size. For instance, a standard small `Size 1' capsule with a dimension of 6.91 mm × 19.4 mm would be appropriate. |
---|---|
AbstractList | Endoscopy is a medical procedure carrying out in-vivo tests. The conventional wired endoscopy process is pain staking and time consuming. An alternative to this wired one would be a wireless endoscope system. Various pill type endoscopes such as iPill, Sayaka, and Smart Pill have been developed for drug delivery, imaging, and pH sensing in the stomach and intestines. The current device size of approximately 10 mm × 20 mm allows the usage of products only for a human adult as the average diameter of adult upper esophagus of approximately 13 mm is large enough to accommodate such devices while they are too big for children. To extend the usage of such wireless endoscopy to pediatric applications, pill should be greatly reduced in size. For instance, a standard small `Size 1' capsule with a dimension of 6.91 mm × 19.4 mm would be appropriate. |
Author | Shirvante, Vivek Xiaoyu Cheng Todeschini, Fabien Yong-Kyu Yoon |
Author_xml | – sequence: 1 givenname: Vivek surname: Shirvante fullname: Shirvante, Vivek email: vs38@buffalo.edu organization: Dept. of Electr. Eng., Univ. at Buffalo, Buffalo, NY, USA – sequence: 2 givenname: Fabien surname: Todeschini fullname: Todeschini, Fabien organization: Dept. of Electr. Eng., Univ. at Buffalo, Buffalo, NY, USA – sequence: 3 surname: Xiaoyu Cheng fullname: Xiaoyu Cheng organization: Dept. of Electr. Eng., Univ. at Buffalo, Buffalo, NY, USA – sequence: 4 surname: Yong-Kyu Yoon fullname: Yong-Kyu Yoon organization: Dept. of Electr. Eng., Univ. at Buffalo, Buffalo, NY, USA |
BookMark | eNpFkF9LwzAUxaNuYDd9F3zJF-jMTZOmeRzFP4OJwtTXcZveQaRLSlMYfnsLDnw65_CDw-Es2CzEQIzdgVgBCPuwft-tpJiS1iWISl-wBSiplLJlpS9ZBlaZHJSFq39gzGwCWsq8sKWes8yKvFSisOaaLVL6FkIWBnTGvup47NGNPPV-wI5jGCkETPwQB_66qXe8wdDykx-oo5Q4hTYmF3viYzzh0PKeWo_j4B3Hvu-8w9HHkG7Y_IBdotuzLtnn0-NH_ZJv35439XqbezB6zImmUdgQmgNKIxuNLYBprdNNKXUFzoFSoJvJm0o4q6TQxkkhCqepRCiW7P6v1xPRvh_8EYef_fmo4hcb1lgi |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/APS.2010.5561085 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Xplore IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Xplore url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISBN | 1424449685 9781424449682 |
EISSN | 1947-1491 |
EndPage | 4 |
ExternalDocumentID | 5561085 |
Genre | orig-research |
GroupedDBID | 23M 29G 6IE 6IF 6IH 6IK 6IL 6IM 6IN AAJGR ABLEC ACGFS ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK IJVOP IPLJI JC5 M43 OCL RIE RIL RIO RNS |
ID | FETCH-LOGICAL-i175t-ee640abea7fa272b5ad117d9c5b62581cc14415b258780c942057c2003c5e6a13 |
IEDL.DBID | RIE |
ISBN | 1424449677 9781424449675 |
ISSN | 1522-3965 |
IngestDate | Wed Jun 26 19:24:22 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | false |
LCCN | 90-640397 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i175t-ee640abea7fa272b5ad117d9c5b62581cc14415b258780c942057c2003c5e6a13 |
PageCount | 4 |
ParticipantIDs | ieee_primary_5561085 |
PublicationCentury | 2000 |
PublicationDate | 2010-July |
PublicationDateYYYYMMDD | 2010-07-01 |
PublicationDate_xml | – month: 07 year: 2010 text: 2010-July |
PublicationDecade | 2010 |
PublicationTitle | 2010 IEEE Antennas and Propagation Society International Symposium |
PublicationTitleAbbrev | APS |
PublicationYear | 2010 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0023715 ssj0000451984 |
Score | 1.507279 |
Snippet | Endoscopy is a medical procedure carrying out in-vivo tests. The conventional wired endoscopy process is pain staking and time consuming. An alternative to... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 1 |
SubjectTerms | Endoscopes Microwave integrated circuits Receiving antennas Transmitting antennas Wireless communication Wireless sensor networks |
Title | Compact spiral antennas for MICS band wireless endoscope toward pediatric applications |
URI | https://ieeexplore.ieee.org/document/5561085 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwED61nWDh0SLe8sCIWzdx4nhECFQhFVWCom6VHxcJUaUVpAu_HttJSkEMbE6iJM4p8t35vu8-gCsmLEepcqp1hpSj5VRHLKZSM6vy1DnEzJOTx4_paMofZsmsBdcbLgwiBvAZ9v0w1PLt0qz9VtnASzm6EKENbSFlxdXa7KeEPimec1knW7EI6gXOPUU0lmnSkLq4TIVoej3Vx0lTv2RycDN5qgBf9ct-qK4Ep3O_B-NmuhXW5K2_LnXffP7q5Pjf79mH3je9j0w2jusAWlgcwu5WZ8IuvIR1wpQkFOIXxNu_KNQHcTEu8bqHRKvCEt_oeOHWSoKFXQaCCykDDpesGgkQsl0i78H0_u75dkRrCQb66uKKkiKmnCmNSuQqEpFOlB0OhZUm0S5xyobGhIRMu7HImJE8cvGf8YA3k2CqhvERdIplgcdA3M3WSsZ0nuQ8chczYfNYefKre0gcn0DXW2i-qrpszGvjnP59-gx2qjq-B86eQ6d8X-OFCw9KfRn-iy-ztrM_ |
link.rule.ids | 310,311,783,787,792,793,799,27939,55088 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3LT8IwGP-CeFAvPtD4tgePFsbWruvRGAkqEBLBcCN9LTGSQXRc_Ottuw3RePDWbdmrW_p97fd7AFwHTBPDRYqlTAwmRhMswyDCXAZapLENiIkjJ_cHcXdMHid0UoObFRfGGOPBZ6bpmr6Wr-dq6ZbKWs7K0aYIG7BJXV5RsLVWKypeKcWxLsvpVsS8f4ENUCGOeEwrWhfhMWOV2lO5TasKZsBbt8PnAvJV3u6H74oPO51d6FcPXKBN3prLXDbV5y8tx_--0R4cfhP80HAVuvahZrID2FnTJmzAix8pVI58KX6G3BfIMvGBbJaLnPMhkiLTyEkdz-xoiUym557ignKPxEWLygQErRfJD2HcuR_ddXFpwoBfbWaRY2NiEghpBEtFyEJJhW63meaKSjt1StpK-SmZtG2WBIqT0GaAykHeFDWxaEdHUM_mmTkGZE_WmgeBTGlKQnswYTqNhKO_2otE0Qk0XA9NF4XOxrTsnNO_d1_BVnfU7017D4OnM9guqvoORnsO9fx9aS5sspDLS_-PfAFNdbaM |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2010+IEEE+Antennas+and+Propagation+Society+International+Symposium&rft.atitle=Compact+spiral+antennas+for+MICS+band+wireless+endoscope+toward+pediatric+applications&rft.au=Shirvante%2C+Vivek&rft.au=Todeschini%2C+Fabien&rft.au=Xiaoyu+Cheng&rft.au=Yong-Kyu+Yoon&rft.date=2010-07-01&rft.pub=IEEE&rft.isbn=9781424449675&rft.issn=1522-3965&rft.eissn=1947-1491&rft.spage=1&rft.epage=4&rft_id=info:doi/10.1109%2FAPS.2010.5561085&rft.externalDocID=5561085 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1522-3965&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1522-3965&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1522-3965&client=summon |