Phasor measurement unit integration: A review on optimal PMU placement methods in power system
The Phasor Measurement Unit (PMU) is an imperative part for monitoring, protecting and controlling the current power system. For the current power systems, PMUs not only offer the synchronized measurements of real-time data of voltage but also the current and frequency. Placement of PMUs in each bus...
Saved in:
Published in | 2017 IEEE Region 10 Humanitarian Technology Conference (R10-HTC) pp. 328 - 332 |
---|---|
Main Authors | , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.12.2017
|
Subjects | |
Online Access | Get full text |
ISSN | 2572-7621 |
DOI | 10.1109/R10-HTC.2017.8288967 |
Cover
Loading…
Abstract | The Phasor Measurement Unit (PMU) is an imperative part for monitoring, protecting and controlling the current power system. For the current power systems, PMUs not only offer the synchronized measurements of real-time data of voltage but also the current and frequency. Placement of PMUs in each bus for monitoring the system is not feasible from economic point of view and also for big data handling. So it is an obligatory matter to reduce the number of PMUs in the bus system with the aim of attaining the maximum power system observation. Different techniques are being applied from past to present to solve this optimum PMU placement (OPP) problem such as heuristic method, mathematical programing. Heuristic method is a quick experience-based technique for solving the optimization problems. Various optimization methods for solving the OPP problems are being reviewed in this paper. |
---|---|
AbstractList | The Phasor Measurement Unit (PMU) is an imperative part for monitoring, protecting and controlling the current power system. For the current power systems, PMUs not only offer the synchronized measurements of real-time data of voltage but also the current and frequency. Placement of PMUs in each bus for monitoring the system is not feasible from economic point of view and also for big data handling. So it is an obligatory matter to reduce the number of PMUs in the bus system with the aim of attaining the maximum power system observation. Different techniques are being applied from past to present to solve this optimum PMU placement (OPP) problem such as heuristic method, mathematical programing. Heuristic method is a quick experience-based technique for solving the optimization problems. Various optimization methods for solving the OPP problems are being reviewed in this paper. |
Author | Roy, Vishwajit Bayne, Stephen B. Noureen, Subrina Sultana |
Author_xml | – sequence: 1 givenname: Subrina Sultana surname: Noureen fullname: Noureen, Subrina Sultana organization: Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas-79409 – sequence: 2 givenname: Vishwajit surname: Roy fullname: Roy, Vishwajit organization: Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas-79409 – sequence: 3 givenname: Stephen B. surname: Bayne fullname: Bayne, Stephen B. organization: Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas-79409 |
BookMark | eNotkN9OwjAchavRRMQ9gV70BYb9s62dd4SImGAkBm4l7far1LB2aYuEt3cJXJ2ci-_ky7lHN847QOiJkgmlpH7-oiRfrGcTRqiYSCZlXYkrlNVC0pLLilFRsms0YqVguRjqHcpi_CWEcFoTUvER-l7tVPQBd6DiIUAHLuGDswlbl-AnqGS9e8FTHODPwhF7h32fbKf2ePWxwf1eNWemg7TzbRww3PsjBBxPMUH3gG6N2kfILjlGm_nrerbIl59v77PpMreDYspbVQrKdMkLCaCbghSykTXR3JSt4VQUUEldNYI1rSwI0dIYbkwtaMM1azXwMXo871oA2PZhMAyn7eUR_g-MElh3 |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/R10-HTC.2017.8288967 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE/IET Electronic Library url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Social Welfare & Social Work Engineering |
EISBN | 9781538621752 1538621754 |
EISSN | 2572-7621 |
EndPage | 332 |
ExternalDocumentID | 8288967 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IL 6IN AAJGR AAWTH ABLEC ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK OCL RIE RIL |
ID | FETCH-LOGICAL-i175t-da5712b5348eebc4048c890b3f5df3174e68b6c72cd8400b8ff3ff971c3b2dbe3 |
IEDL.DBID | RIE |
IngestDate | Wed Aug 27 02:51:31 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i175t-da5712b5348eebc4048c890b3f5df3174e68b6c72cd8400b8ff3ff971c3b2dbe3 |
PageCount | 5 |
ParticipantIDs | ieee_primary_8288967 |
PublicationCentury | 2000 |
PublicationDate | 2017-Dec. |
PublicationDateYYYYMMDD | 2017-12-01 |
PublicationDate_xml | – month: 12 year: 2017 text: 2017-Dec. |
PublicationDecade | 2010 |
PublicationTitle | 2017 IEEE Region 10 Humanitarian Technology Conference (R10-HTC) |
PublicationTitleAbbrev | R10-HTC |
PublicationYear | 2017 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0003190063 ssj0001968470 |
Score | 1.7782533 |
Snippet | The Phasor Measurement Unit (PMU) is an imperative part for monitoring, protecting and controlling the current power system. For the current power systems,... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 328 |
SubjectTerms | Current measurement Global Positioning System (GPS) Heuristic algorithm Observability Optimal Placement of PMU (OPP) Optimization Phasor Measurement Unit (PMU) Phasor measurement units Power system stability State Estimation (SE) Supervisory Control and Data Acquisition (SCADA) Voltage measurement |
Title | Phasor measurement unit integration: A review on optimal PMU placement methods in power system |
URI | https://ieeexplore.ieee.org/document/8288967 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3NT8IwFG-Qk15UwPiBpgfjyY1t3ac3QyTEBEMMRE6StXuNBtnI2C7-9b6uA9R48LY1e0vT176vvt97hFwD85kberHBuRsYrgSUg2hHGGhch4D6VEIVhxw9-cOp-zjzZg1yu8XCAECVfAameqzu8pNMlCpU1kPvIIz8YI_soeOmsVq7eErko6C1tu-4tZT6rdFythX1nlHiDCd9lc4VmPWvfvRUqVTK4JCMNpPRmSQLsyy4KT5_1Wn872yPSGcH3qPjrVo6Jg1IW-TgW93BFulqUC59gQ8Z50Bv6GYgyxdt8jp-i9dZTpe7-CEt8ejTTW0J5OUdvaca9kKzlGYoeJZIPx5NaZXlVdHo7tRrJKMr1YyN6rLRHTIdPEz6Q6Puw2C8o3FRGEnsBbbDPWQqABcuHnoRRhZn0ksk2h8u-CH3ReCIBN1Fi4dSMimjwBaMOwkHdkKaaZbCKaGWH-MHQgaq7pG682VOJCPXUVgAllj2GWmrhZyvdKmNeb2G538PX5B9xUydXdIlzSIv4RJthIJfVZvjCw-6usU |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHtSLChgfqHswnmzp--HNEElVIMRA5CTptrPRIC2BcvHXO9vyUOPBW7vpNpud3ZnZ2fm-AbhC0zEtzw4Vzi1XsQSSHiQ_QiHn2kOypwLzOGSn6wQD63FoD0tws8bCIGKefIaqfMzv8uM0WshQWYNOB57vuFuwTXbf8gu01iai4jukarX1Oy0uaYCXeDld8xvPpHOCflMmdLnq8mc_qqrkRqW1D53VcIpckrG6yLgaff5iavzveA-gtoHvsd7aMB1CCZMK7H1jHqxAvYDlshf8EOEM2TVbNaSzcRVee2_hPJ2xySaCyBa0-dmKXYKkecvuWAF8YWnCUlI9E-rf6wxYnueV9ynqU8-pG5vKcmysII6uwaB1328GyrISg_JO7kWmxKHt6ga3SayIPLJo20eer3FT2LEgD8RCx-NO5BpRTAdGjXtCmEL4rh6Z3Ig5mkdQTtIEj4FpTkgfRMKVzEfy1tc0fOFbhkQDmLGmn0BVTuRoWpBtjJZzePp38yXsBP1Oe9R-6D6dwa4UbJFrUodyNlvgOXkMGb_IF8oXCia-FQ |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2017+IEEE+Region+10+Humanitarian+Technology+Conference+%28R10-HTC%29&rft.atitle=Phasor+measurement+unit+integration%3A+A+review+on+optimal+PMU+placement+methods+in+power+system&rft.au=Noureen%2C+Subrina+Sultana&rft.au=Roy%2C+Vishwajit&rft.au=Bayne%2C+Stephen+B.&rft.date=2017-12-01&rft.pub=IEEE&rft.eissn=2572-7621&rft.spage=328&rft.epage=332&rft_id=info:doi/10.1109%2FR10-HTC.2017.8288967&rft.externalDocID=8288967 |