Wireless ambulatory ECG signal capture for HRV and cognitive load study using the NeuroMonitor platform

The heart rhythms, controlled by the autonomic nervous system, can fluctuate with varying cognitive loads that can be captured with electrocardiogram (ECG) and heart rate variability (HRV) metrics. In this paper, we report customization of a wireless, ambulatory NeuroMonitor device originally develo...

Full description

Saved in:
Bibliographic Details
Published in2013 6th International IEEE/EMBS Conference on Neural Engineering (NER) pp. 497 - 500
Main Authors Sahadat, Md Nazmus, Consul-Pacareu, S., Morshed, Bashir I.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.11.2013
Subjects
Online AccessGet full text
ISSN1948-3546
DOI10.1109/NER.2013.6695980

Cover

Abstract The heart rhythms, controlled by the autonomic nervous system, can fluctuate with varying cognitive loads that can be captured with electrocardiogram (ECG) and heart rate variability (HRV) metrics. In this paper, we report customization of a wireless, ambulatory NeuroMonitor device originally developed for collecting electroencephalogram (EEG) signals as a platform for ECG and HRV data collection. The overall gain is altered to 93.86, while the band pass filter was set to 0.5 Hz to 126 Hz. The four independent inputs were connected to left arm, right arm, left leg and right leg. ECG signal and HRV data was collected during relax state and elevated cognitive load conditions. The signals were digitized at 256 sps and wirelessly transmitted to a remote computer for analysis. These cardiac signals were filtered and plotted using MATLAB. We demonstrate successful data collection that enables multiple applications of NeuroMonitor platform as an ambulatory physiological parameter monitoring hardware for long duration study of patients in natural settings.
AbstractList The heart rhythms, controlled by the autonomic nervous system, can fluctuate with varying cognitive loads that can be captured with electrocardiogram (ECG) and heart rate variability (HRV) metrics. In this paper, we report customization of a wireless, ambulatory NeuroMonitor device originally developed for collecting electroencephalogram (EEG) signals as a platform for ECG and HRV data collection. The overall gain is altered to 93.86, while the band pass filter was set to 0.5 Hz to 126 Hz. The four independent inputs were connected to left arm, right arm, left leg and right leg. ECG signal and HRV data was collected during relax state and elevated cognitive load conditions. The signals were digitized at 256 sps and wirelessly transmitted to a remote computer for analysis. These cardiac signals were filtered and plotted using MATLAB. We demonstrate successful data collection that enables multiple applications of NeuroMonitor platform as an ambulatory physiological parameter monitoring hardware for long duration study of patients in natural settings.
Author Morshed, Bashir I.
Sahadat, Md Nazmus
Consul-Pacareu, S.
Author_xml – sequence: 1
  givenname: Md Nazmus
  surname: Sahadat
  fullname: Sahadat, Md Nazmus
  email: mnshadat@memphis.edu
  organization: Electr. & Comput. Eng. Dept., Univ. of Memphis, Memphis, TN, USA
– sequence: 2
  givenname: S.
  surname: Consul-Pacareu
  fullname: Consul-Pacareu, S.
  email: scpacreu@memphis.edu
  organization: Electr. & Comput. Eng. Dept., Univ. of Memphis, Memphis, TN, USA
– sequence: 3
  givenname: Bashir I.
  surname: Morshed
  fullname: Morshed, Bashir I.
  email: bmorshed@memphis.edu
  organization: Electr. & Comput. Eng. Dept., Univ. of Memphis, Memphis, TN, USA
BookMark eNotkM1Kw0AYRUdQsK3dC27mBVLny_wvpdRWqBWKP8sySb7EkTRTZhKhb2_Aru7mnLO4U3LdhQ4JuQe2AGD2cbfaL3IGfKGUldawKzIFoTQHq6y4JhOwwmRcCnVL5in9MMZ4zgRYMyHNl4_YYkrUHYuhdX2IZ7parmnyTedaWrpTP0SkdYh0s_-krqtoGZrO9_4XaRtcRVM_VGc6JN81tP9GusMhhtcwIqNzGpOje7wjN7VrE84vOyMfz6v35Sbbvq1flk_bzIOWfVYYx43JQWtZlbl0VliGKlfGWQZCgygKxlVdaFGVEoEbKAona9DG1gptzmfk4b_rEfFwiv7o4vlw-YX_AcZ0WNE
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/NER.2013.6695980
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Anatomy & Physiology
EISBN 1467319694
9781467319690
EndPage 500
ExternalDocumentID 6695980
Genre orig-research
GroupedDBID 6IE
6IF
6IL
6IN
AAWTH
ABLEC
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
OCL
RIE
RIL
ID FETCH-LOGICAL-i175t-b8a38821775dc25a9490e6268a9014714bb036fb74dc5e1381bba5f1789f6e923
IEDL.DBID RIE
ISSN 1948-3546
IngestDate Wed Aug 27 03:54:08 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-b8a38821775dc25a9490e6268a9014714bb036fb74dc5e1381bba5f1789f6e923
PageCount 4
ParticipantIDs ieee_primary_6695980
PublicationCentury 2000
PublicationDate 2013-Nov.
PublicationDateYYYYMMDD 2013-11-01
PublicationDate_xml – month: 11
  year: 2013
  text: 2013-Nov.
PublicationDecade 2010
PublicationTitle 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER)
PublicationTitleAbbrev NER
PublicationYear 2013
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0003204198
ssj0001766588
Score 1.5527472
Snippet The heart rhythms, controlled by the autonomic nervous system, can fluctuate with varying cognitive loads that can be captured with electrocardiogram (ECG) and...
SourceID ieee
SourceType Publisher
StartPage 497
SubjectTerms Arrays
Bluetooth
Computers
Electrocardiography
Electroencephalography
Heart rate variability
MATLAB
Title Wireless ambulatory ECG signal capture for HRV and cognitive load study using the NeuroMonitor platform
URI https://ieeexplore.ieee.org/document/6695980
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELZKJyYeLeKtGxATTvOwnWREVUuFRIUqirpVduxUiJJUVTuUX8_ZKalADGxJBstyrPu-u_vujpAbgSCgBc-oCfOcMsMZVUgUaGBYwKSxqOFUvkMxGLPHCZ80yF1dC2OMceIz49lHl8vXZba2obKOEClPE3TQ9_CaVbVau3hKLBBMk_o9Cn0WuFG46KYnNOKszlL6aWfYG1lZV-Rtl_wxW8VBS_-APH1vqlKUvHvrlfKyz1_9Gv-760PS3hXxwXMNT0ekYYpj0rov0Mv-2MAtOO2nC6q3yMyKYOdo9EB-KDvQq1xuoNd9ACvvkHPI5MJmGgAZLgxGryALDbXwCOal1OD61IKV0c8ASSW4rh-VxVjCApe07LhNxv3eS3dAtyMY6BvyihVViYyQgwdxzHUWcpmy1DfoAyXSpl_jgCmFEJirmOmMmwDhXynJ8yBO0lwYJI8npFmUhTklgFwP3SclfcWQxWiZchYZGTLB0MjoUJ6Rlj276aLqsjHdHtv5358vyL79f1VV4CVprpZrc4X0YKWu3b34AkGitos
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEN4QPejJBxjfzsF4sqWP3T6OhoBVgRgChhvZbbfECC0h5YC_3tktlmg8eGt72Gy2m_m-mflmhpBbD0Eg8VhsSCdNDSoZNQQSBcOW1KZcKtTQKt--F43o85iNa-S-qoWRUmrxmTTVo87lJ3m8UqGypueFLAzQQd9F3KesrNbaRlR8D-E0qN5dx6K2HoaLjnpguIxWeUorbPbbAyXscs3Noj-mq2hw6RyQ3ve2Sk3Jh7kqhBl__urY-N99H5LGtowPXiuAOiI1mR2T-kOGfvZ8DXeg1Z86rF4nUyWDnaHZAz4XaqRXvlxDu_UISuDBZxDzhco1AHJciAZvwLMEKukRzHKegO5UC0pIPwWklaD7fpQ2YwkLXFLx4wYZddrDVmRshjAY78gsCkME3EUWbvs-S2KH8ZCGlkQvKOAqAevbVAgEwVT4NImZtJEACMFZavtBmHoS6eMJ2cnyTJ4SQLaHDpTglqDIYxIeMupK7lCPoplJHH5G6ursJouyz8Zkc2znf3--IXvRsNeddJ_6LxdkX_3LskbwkuwUy5W8QrJQiGt9R74AATu52A
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2013+6th+International+IEEE%2FEMBS+Conference+on+Neural+Engineering+%28NER%29&rft.atitle=Wireless+ambulatory+ECG+signal+capture+for+HRV+and+cognitive+load+study+using+the+NeuroMonitor+platform&rft.au=Sahadat%2C+Md+Nazmus&rft.au=Consul-Pacareu%2C+S.&rft.au=Morshed%2C+Bashir+I.&rft.date=2013-11-01&rft.pub=IEEE&rft.issn=1948-3546&rft.spage=497&rft.epage=500&rft_id=info:doi/10.1109%2FNER.2013.6695980&rft.externalDocID=6695980
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1948-3546&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1948-3546&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1948-3546&client=summon