A modified hybrid model of heat exchanger based on fouling effect
Hybrid model is a simple and accurate model for stable heat transfer process. Its theoretical basis shows that it is inappropriate to be applied to system with severe coefficient drifting. However, coefficient drifting is normal phenomenon in power and chemical industrial due to fouling. In this pap...
Saved in:
Published in | 2011 6th IEEE Conference on Industrial Electronics and Applications pp. 799 - 804 |
---|---|
Main Authors | , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
01.06.2011
|
Subjects | |
Online Access | Get full text |
ISBN | 9781424487547 1424487544 |
ISSN | 2156-2318 |
DOI | 10.1109/ICIEA.2011.5975695 |
Cover
Abstract | Hybrid model is a simple and accurate model for stable heat transfer process. Its theoretical basis shows that it is inappropriate to be applied to system with severe coefficient drifting. However, coefficient drifting is normal phenomenon in power and chemical industrial due to fouling. In this paper, a modified hybrid model of heat exchanger is proposed. The derivation of system is based on heat transfer balance and fouling principle of the heat exchanger. Considering fouling effect, a comprehensive model is derived. The catalog results with experiment data show that the proposed model can predict accurately the real-time performance of heat exchanger with error less than 3%. This model can be used in heat exchanger with high fouling risk for operational optimization, performance assessment and device maintaining. |
---|---|
AbstractList | Hybrid model is a simple and accurate model for stable heat transfer process. Its theoretical basis shows that it is inappropriate to be applied to system with severe coefficient drifting. However, coefficient drifting is normal phenomenon in power and chemical industrial due to fouling. In this paper, a modified hybrid model of heat exchanger is proposed. The derivation of system is based on heat transfer balance and fouling principle of the heat exchanger. Considering fouling effect, a comprehensive model is derived. The catalog results with experiment data show that the proposed model can predict accurately the real-time performance of heat exchanger with error less than 3%. This model can be used in heat exchanger with high fouling risk for operational optimization, performance assessment and device maintaining. |
Author | Lei Zhao Xudong Ding Wenjian Cai |
Author_xml | – sequence: 1 surname: Lei Zhao fullname: Lei Zhao organization: Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore, Singapore – sequence: 2 surname: Wenjian Cai fullname: Wenjian Cai organization: Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore, Singapore – sequence: 3 surname: Xudong Ding fullname: Xudong Ding organization: Sch. of Inf. & Electr. Eng., Shandong Jianzhu Univ., Jinan, China |
BookMark | eNpVUM1OwzAYC2JIjNEXgEteoCVffprmWFVjVJrEBc5T0nxZg7oWtUVib08Ru-CLZcv2wXdk1Q89EvIALANg5qmu6m2ZcQaQKaNVbtQVSYwuQHIpi8WA639a6hVZc1B5ygUUtySZpg-2IM8N52pNypKeBh9DRE_bsxuj_9XY0SHQFu1M8btpbX_EkTo7LaGhp2H46mJ_pBgCNvM9uQm2mzC58Ia8P2_fqpd0_7qrq3KfRtBqTo0JnDeNy5kDaBg6y7RQ3msBzHOBGJxf7MIKI4MrLOfMS-3E0gvgrBUb8vi3GxHx8DnGkx3Ph8sJ4gf1R0-j |
ContentType | Conference Proceeding |
DBID | 6IE 6IL CBEJK RIE RIL |
DOI | 10.1109/ICIEA.2011.5975695 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISBN | 9781424487561 1424487552 9781424487554 1424487560 |
EndPage | 804 |
ExternalDocumentID | 5975695 |
Genre | orig-research |
GroupedDBID | 6IE 6IF 6IL 6IN AAWTH ABLEC ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK OCL RIE RIL |
ID | FETCH-LOGICAL-i175t-99f22ccb60b11c0eba0735dd7310d23eefbdc0e8a394fb8a220d47b399ff1baa3 |
IEDL.DBID | RIE |
ISBN | 9781424487547 1424487544 |
ISSN | 2156-2318 |
IngestDate | Wed Aug 27 03:01:00 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i175t-99f22ccb60b11c0eba0735dd7310d23eefbdc0e8a394fb8a220d47b399ff1baa3 |
PageCount | 6 |
ParticipantIDs | ieee_primary_5975695 |
PublicationCentury | 2000 |
PublicationDate | 2011-June |
PublicationDateYYYYMMDD | 2011-06-01 |
PublicationDate_xml | – month: 06 year: 2011 text: 2011-June |
PublicationDecade | 2010 |
PublicationTitle | 2011 6th IEEE Conference on Industrial Electronics and Applications |
PublicationTitleAbbrev | ICIEA |
PublicationYear | 2011 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0000669225 ssj0003177831 |
Score | 1.4658308 |
Snippet | Hybrid model is a simple and accurate model for stable heat transfer process. Its theoretical basis shows that it is inappropriate to be applied to system with... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 799 |
SubjectTerms | Data models Equations Fitting Fluids fouling heat exchanger Heat transfer Heating hybrid model Mathematical model |
Title | A modified hybrid model of heat exchanger based on fouling effect |
URI | https://ieeexplore.ieee.org/document/5975695 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3JTsMwEB21PcGFpUXs8oEjbrM4iX2sqlYtUhEHKvVWxRtUiAShVAK-nnGWsogDt9iHxLFGfk_jeW8ArpjwmRZxQAXzFWWpCKhMEkOZDpmOnENc5ATO89t4umA3y2jZguutFsYYUxafmb57LO_yda42LlU2QPIbxSJqQxvDrNJqbfMpCJ2iiU03RlxMeNmOEEEtpkhjeKPr4s70rbF7qsdJI6jxxGA2mo2Hlbtn_cUfrVdK5JnswbxZc1Vw8tTfFLKvPn7ZOf73p_ah96XxI3db9DqAlskOYfebPWEXhkPynOu1RZZKHt-dtIuUjXNIbok7w4l5q3XDxIGhJnlGrOuwnj2Qqk6kB4vJ-H40pXXLBbpGHlFQIWwQKCVjT_q-8oxM8QiItE6QBeogNMZKjdM8DQWzkqdB4GmWSGQ51voyTcMj6GR5Zo6BhJaHnkJ-yGzo9PaSe1xorgy-TFljT6DrNmP1UrlqrOp9OP17-gx2qmyuy3-cQ6d43ZgLpAOFvCzj4BMu8awi |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1JTwIxGP2CeFAvLmDc7cGjhVk6M-2REAgoEA-QcCPTTQlxxpghUX-97Sy4xIO3aQ-zNE3fyzffew_ghjCXSBZ6mBFXYBIzD_MoUphIn8jAOsQFVuA8noSDGbmbB_Ma3G60MEqpvPlMtexl_i9fpmJtS2VtQ36DkAVbsG1wnwSFWmtTUTHgyardaccGGSOaBxIaWAuxITK0UnZRa_tWGT6V46iS1DisPewOe53C37N85o_wlRx7-vswrt66aDlZtdYZb4mPX4aO__2sA2h-qfzQwwa_DqGmkiPY-2ZQ2IBOBz2ncqkNT0VP71bchfLoHJRqZE9xpN5K5TCycChRmiBtM9aTR1R0ijRh1u9NuwNchi7gpWESGWZMe54QPHS46wpH8dgcAoGUkeGB0vOV0lyaaRr7jGhOY89zJIm44TlauzyO_WOoJ2miTgD5mvqOMAyRaN8q7jl1KJNUKHMzoZU-hYZdjMVL4auxKNfh7O_pa9gZTMejxWg4uT-H3aK2a6shF1DPXtfq0pCDjF_le-ITaqOvbw |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2011+6th+IEEE+Conference+on+Industrial+Electronics+and+Applications&rft.atitle=A+modified+hybrid+model+of+heat+exchanger+based+on+fouling+effect&rft.au=Lei+Zhao&rft.au=Wenjian+Cai&rft.au=Xudong+Ding&rft.date=2011-06-01&rft.pub=IEEE&rft.isbn=9781424487547&rft.issn=2156-2318&rft.spage=799&rft.epage=804&rft_id=info:doi/10.1109%2FICIEA.2011.5975695&rft.externalDocID=5975695 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2156-2318&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2156-2318&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2156-2318&client=summon |