Magnetometric Sensitivity and Spin Relaxation of Buffered Gas Cell for Cardiomagnetometer

We investigated a diode-pumped Cs-based Mx type atomic magnetometer developed aiming the detection of low magnetic fields of the human heartbeat. In this study, we characterized and optimized the rf coil voltage and the laser power to achieve the minimum magnetic resonance linewidth for the best sen...

Full description

Saved in:
Bibliographic Details
Published in2019 IEEE International Symposium on Medical Measurements and Applications (MeMeA) pp. 1 - 5
Main Authors Araz, Isa, Yorulmaz, Ismail, Meraki, Adil, Kacar, Birgul, Kubanaliev, Bakmurat
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.06.2019
Subjects
Online AccessGet full text

Cover

Loading…
Abstract We investigated a diode-pumped Cs-based Mx type atomic magnetometer developed aiming the detection of low magnetic fields of the human heartbeat. In this study, we characterized and optimized the rf coil voltage and the laser power to achieve the minimum magnetic resonance linewidth for the best sensitivity. The measured half-width of an 18 Hz at half maximum and a signal-to-noise ratio of 22800 with shot-noise-limited were obtained. The sensitivity of the magnetometer was shown to be around 228 fT/√Hz which is under the required limit for the cardiomagnetometer applications.
AbstractList We investigated a diode-pumped Cs-based Mx type atomic magnetometer developed aiming the detection of low magnetic fields of the human heartbeat. In this study, we characterized and optimized the rf coil voltage and the laser power to achieve the minimum magnetic resonance linewidth for the best sensitivity. The measured half-width of an 18 Hz at half maximum and a signal-to-noise ratio of 22800 with shot-noise-limited were obtained. The sensitivity of the magnetometer was shown to be around 228 fT/√Hz which is under the required limit for the cardiomagnetometer applications.
Author Meraki, Adil
Araz, Isa
Kacar, Birgul
Kubanaliev, Bakmurat
Yorulmaz, Ismail
Author_xml – sequence: 1
  givenname: Isa
  surname: Araz
  fullname: Araz, Isa
  organization: Atomic Sensors Laboratory, TUBITAK National Metrology Institute, Kocaeli, Turkey
– sequence: 2
  givenname: Ismail
  surname: Yorulmaz
  fullname: Yorulmaz, Ismail
  organization: Atomic Sensors Laboratory, TUBITAK National Metrology Institute, Kocaeli, Turkey
– sequence: 3
  givenname: Adil
  surname: Meraki
  fullname: Meraki, Adil
  organization: Atomic Sensors Laboratory, TUBITAK National Metrology Institute, Kocaeli, Turkey
– sequence: 4
  givenname: Birgul
  surname: Kacar
  fullname: Kacar, Birgul
  organization: Atomic Sensors Laboratory, TUBITAK National Metrology Institute, Kocaeli, Turkey
– sequence: 5
  givenname: Bakmurat
  surname: Kubanaliev
  fullname: Kubanaliev, Bakmurat
  organization: Atomic Sensors Laboratory, TUBITAK National Metrology Institute, Kocaeli, Turkey
BookMark eNo9z8tKw0AUgOERFLS1L6CbeYHEuWRuyxq0Cg2C1YWrcjo5IyPJpEyi2LdXsLj6dx_8M3KahoSEXHFWcs7cTYMNLkvBuCutZYJLfUJmXEmrbSVsdU4W4_jBGBNWKi3FBXlr4D3hNPQ45ejpBtMYp_gVpwOF1NLNPib6jB18wxSHRIdAbz9DwIwtXcFIa-w6GoZMa8htHPp_DPMlOQvQjbg4dk5e7-9e6odi_bR6rJfrInKjpsIEoZmTDLz1zrnWCA-VFmDQCQygvd9pZZStmAnc75iFFqX01lSKK_U7MSfXf25ExO0-xx7yYXu8lz80pVLu
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/MeMeA.2019.8802136
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library Online
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library Online
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1538684284
9781538684283
EndPage 5
ExternalDocumentID 8802136
Genre orig-research
GroupedDBID 6IE
6IF
6IL
6IN
AAJGR
ABLEC
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
IEGSK
OCL
RIE
RIL
ID FETCH-LOGICAL-i175t-7f260930ac8c999d72ca462a7e92efa6ccb65758407f1cb08ade33c8745155563
IEDL.DBID RIE
IngestDate Thu Jun 29 18:38:48 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-7f260930ac8c999d72ca462a7e92efa6ccb65758407f1cb08ade33c8745155563
PageCount 5
ParticipantIDs ieee_primary_8802136
PublicationCentury 2000
PublicationDate 2019-June
PublicationDateYYYYMMDD 2019-06-01
PublicationDate_xml – month: 06
  year: 2019
  text: 2019-June
PublicationDecade 2010
PublicationTitle 2019 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
PublicationTitleAbbrev MeMeA
PublicationYear 2019
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0002835632
Score 1.7345477
Snippet We investigated a diode-pumped Cs-based Mx type atomic magnetometer developed aiming the detection of low magnetic fields of the human heartbeat. In this...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms cardio magnetometer
high precision magnetometry
optically detected magnetic resonance
Title Magnetometric Sensitivity and Spin Relaxation of Buffered Gas Cell for Cardiomagnetometer
URI https://ieeexplore.ieee.org/document/8802136
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA7bTp5UNvE3OXi0W9NmTXvU4hxCRZiDeRr58SLDrR2zBfGvN0m3iuLBWwm0De8F3pfk-96H0JX0E0U0N8hNMuHRUCgvJkR4ARGmoCtBmG_1ztljNJ7Sh9lw1kLXjRYGABz5DPr20d3lq0JW9qhsYNZaQMKojdosSWqtVnOeYvuGRWGw08X4ySCDDG4secuuBvfiDwcVV0BG-yjb_brmjbz1q1L05eevroz_ndsB6n1L9fBTU4QOUQvyLnrJ-GsOZbGydlkSTyxJvXaJwDxXeLJe5Niy4D5cWnCh8W3lfFIUvufvOIXlEhswi1NHVl01H4NND01Hd8_p2Nt6KHgLAwxKj2mzYUlCn8tYGiyoWCA5jQLOIAlA80hKYa9ezDaPaSKFH3MFYShtE3yDNExEj1AnL3I4RlgL4JRajZYUVGoaA-OR1iapYqi1ECeoa8MyX9dtMubbiJz-PXyG9mxqatbVOeqUmwouTH0vxaVL7BetnKe0
link.rule.ids 310,311,783,787,792,793,799,27937,55086
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHvSkBoxv9-DRQl_0cVQiolJiAiR4IvuYNURoCbaJ8de7uwWMxoO3ZpO2m5lN5tvd75sP4IrbsXAkVciNh8zyPSasyHGY5TpMFXTBnNDWeuekH3RH_uO4Na7A9UYLg4iGfIYN_Wju8kXGC31U1lRrzXW8YAu2Fa6OglKttTlR0Z3DAs9dK2PsuJlggjeavqXXg3n1h4eKKSGdPUjWPy-ZI2-NImcN_vmrL-N_Z7cP9W-xHnnelKEDqGBag5eEvqaYZ3NtmMXJQNPUS58IQlNBBotpSjQP7sMkhmSS3BbGKUWQe_pO2jibEQVnSdvQVeebj-GyDqPO3bDdtVYuCtZUQYPcCqXassSeTXnEFRoUocupH7g0xNhFSQPOmb58URu9UDqc2REV6Hlct8FXWENF9BCqaZbiERDJkPq-Vmlx5nPpRxjSQEqVVtaSkrFjqOmwTBZlo4zJKiInfw9fwk53mPQmvYf-0yns6jSVHKwzqObLAs9Vtc_ZhUnyF583qv8
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2019+IEEE+International+Symposium+on+Medical+Measurements+and+Applications+%28MeMeA%29&rft.atitle=Magnetometric+Sensitivity+and+Spin+Relaxation+of+Buffered+Gas+Cell+for+Cardiomagnetometer&rft.au=Araz%2C+Isa&rft.au=Yorulmaz%2C+Ismail&rft.au=Meraki%2C+Adil&rft.au=Kacar%2C+Birgul&rft.date=2019-06-01&rft.pub=IEEE&rft.spage=1&rft.epage=5&rft_id=info:doi/10.1109%2FMeMeA.2019.8802136&rft.externalDocID=8802136