Integrated ultrasound imaging systems based on capacitive micromachined ultrasonic transducer arrays
Capacitive micromachined ultrasonic transducers (CMUTs) overcome many limitations of existing ultrasound transducer technologies enabling new applications of ultrasound, especially for medical imaging and treatment. Some of the most important of these advancements are the ability to fabricate transd...
Saved in:
Published in | IEEE Sensors, 2005 p. 4 pp. |
---|---|
Main Authors | , , , , , , , , |
Format | Conference Proceeding |
Language | English |
Published |
IEEE
2005
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Capacitive micromachined ultrasonic transducers (CMUTs) overcome many limitations of existing ultrasound transducer technologies enabling new applications of ultrasound, especially for medical imaging and treatment. Some of the most important of these advancements are the ability to fabricate transducer arrays with two dimensional geometries and high operating frequencies. Over the past decade, extensive research has been conducted on the fabrication, characterization, and modelling of CMUTs. Current research efforts focus on the integration of CMUTs in systems for new medical imaging tools. This paper briefly reviews CMUT technology and presents imaging results from two CMUT-based imaging systems. The first system is designed for use within a 5-mm endoscopic channel and is based on a two dimensional, 16-element times 16-element, 5-MHz CMUT array. To provide a means of integrating the CMUT array with electronics, each element of the array is connected to a flip-chip bond pad on the back side of the array via a through-wafer interconnect. The array is flip-chip bonded to a custom-designed integrated circuit (IC) that comprises the frontend circuitry for the transducer elements. The array and IC are connected to an FPGA-based data acquisition system that can acquire volumetric imaging data in real time. Volumetric pulse-echo and photoacoustic images obtained with this system are presented. The second system is based on a 64-element, 20-MHz, 2-mm diameter CMUT ring array. This array is also designed for use in catheter-based imaging applications. Ring arrays have the advantage of providing space in the center for a guidewire or other catheter-based instrument. Volumetric images obtained with the ring-array system are also presented |
---|---|
AbstractList | Capacitive micromachined ultrasonic transducers (CMUTs) overcome many limitations of existing ultrasound transducer technologies enabling new applications of ultrasound, especially for medical imaging and treatment. Some of the most important of these advancements are the ability to fabricate transducer arrays with two dimensional geometries and high operating frequencies. Over the past decade, extensive research has been conducted on the fabrication, characterization, and modelling of CMUTs. Current research efforts focus on the integration of CMUTs in systems for new medical imaging tools. This paper briefly reviews CMUT technology and presents imaging results from two CMUT-based imaging systems. The first system is designed for use within a 5-mm endoscopic channel and is based on a two dimensional, 16-element times 16-element, 5-MHz CMUT array. To provide a means of integrating the CMUT array with electronics, each element of the array is connected to a flip-chip bond pad on the back side of the array via a through-wafer interconnect. The array is flip-chip bonded to a custom-designed integrated circuit (IC) that comprises the frontend circuitry for the transducer elements. The array and IC are connected to an FPGA-based data acquisition system that can acquire volumetric imaging data in real time. Volumetric pulse-echo and photoacoustic images obtained with this system are presented. The second system is based on a 64-element, 20-MHz, 2-mm diameter CMUT ring array. This array is also designed for use in catheter-based imaging applications. Ring arrays have the advantage of providing space in the center for a guidewire or other catheter-based instrument. Volumetric images obtained with the ring-array system are also presented |
Author | Khuri-Yakub, B.T. Zhuang, X. Yaralioglu, G.G. Yeh, D.T. Vaithilingam, S. Nikoozadeh, A. Wygant, I.O. Oralkan, O. Sanli Ergun, A. |
Author_xml | – sequence: 1 givenname: I.O. surname: Wygant fullname: Wygant, I.O. – sequence: 2 givenname: D.T. surname: Yeh fullname: Yeh, D.T. – sequence: 3 givenname: X. surname: Zhuang fullname: Zhuang, X. – sequence: 4 givenname: S. surname: Vaithilingam fullname: Vaithilingam, S. – sequence: 5 givenname: A. surname: Nikoozadeh fullname: Nikoozadeh, A. – sequence: 6 givenname: O. surname: Oralkan fullname: Oralkan, O. – sequence: 7 givenname: A. surname: Sanli Ergun fullname: Sanli Ergun, A. – sequence: 8 givenname: G.G. surname: Yaralioglu fullname: Yaralioglu, G.G. – sequence: 9 givenname: B.T. surname: Khuri-Yakub fullname: Khuri-Yakub, B.T. |
BookMark | eNpFUNtOAjEQbRQTAf0CXvoDi71stzuPhqCSEH1An8nQDljDdkm7mPD3NtHEp3OZMyeZmbBR7CMxNpNiLqWAh9Vis3zdzJUQZi4NWAvNFRsr2bQVKAXXbCJsKzQI0-gRG0vQoirS3LJJzl9CKGFUO2Z-FQc6JBzI8_NxSJj7c_Q8dHgI8cDzJQ_UZb7DXAJ95A5P6MIQvol3waW-Q_cZ4v9yDI4XErM_O0ocU8JLvmM3ezxmuv_DKft4Wr4vXqr12_Nq8biugrRmqEwjWltY7ZWD2gF4q9Hs0TWoNIGXWu9MGSklCZy3tZYai-uRGpCi1lM2--0NRLQ9pXJFumz_vqN_AIstW5I |
ContentType | Conference Proceeding |
DBID | 6IE 6IH CBEJK RIE RIO |
DOI | 10.1109/ICSENS.2005.1597796 |
DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP) 1998-present |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 2168-9229 |
ExternalDocumentID | 1597796 |
Genre | orig-research |
GroupedDBID | 29O 6IE 6IF 6IH 6IK 6IL 6IM 6IN AAJGR ABLEC ACGFS ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK IJVOP IPLJI M43 OCL RIE RIL RIO RNS |
ID | FETCH-LOGICAL-i175t-560871754d2c94c99d73a5fac6a23e9d133b52c9221e9cd74313ad13dae691043 |
IEDL.DBID | RIE |
ISBN | 0780390563 9780780390560 |
ISSN | 1930-0395 |
IngestDate | Wed Jun 26 19:21:01 EDT 2024 |
IsPeerReviewed | false |
IsScholarly | true |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-i175t-560871754d2c94c99d73a5fac6a23e9d133b52c9221e9cd74313ad13dae691043 |
ParticipantIDs | ieee_primary_1597796 |
PublicationCentury | 2000 |
PublicationDate | 20050000 |
PublicationDateYYYYMMDD | 2005-01-01 |
PublicationDate_xml | – year: 2005 text: 20050000 |
PublicationDecade | 2000 |
PublicationTitle | IEEE Sensors, 2005 |
PublicationTitleAbbrev | ICSENS |
PublicationYear | 2005 |
Publisher | IEEE |
Publisher_xml | – name: IEEE |
SSID | ssj0020528 ssj0000396328 |
Score | 1.6637291 |
Snippet | Capacitive micromachined ultrasonic transducers (CMUTs) overcome many limitations of existing ultrasound transducer technologies enabling new applications of... |
SourceID | ieee |
SourceType | Publisher |
StartPage | 4 pp. |
SubjectTerms | Biomedical imaging Biomedical transducers Bonding Fabrication Frequency Geometry Medical treatment Ultrasonic imaging Ultrasonic transducer arrays Ultrasonic transducers |
Title | Integrated ultrasound imaging systems based on capacitive micromachined ultrasonic transducer arrays |
URI | https://ieeexplore.ieee.org/document/1597796 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV09b8IwELWAqV36AVW_5aFjDU6cxHhGIKgEqkSR2JBjOxJqCVVIhvbX9-yE0FYdujm2oiSnU97z-e4dQg9Sh4nP45BIyTUBD5GkHzBGuBfLmFGtubLVyNNZNF4ET8tw2UCPdS2MMcYln5muHbqzfL1VhQ2V9TwrliaiJmpyIcparTqeQhm4kl-fIPg0dH1VgZ9QAmuh27L3YQSIzyrlnf01reSIPCp6k8F8OJuXwZbqeT8arzjcGZ2g6f6Ny3ST126Rx131-UvM8b-fdIo6hwo__Fxj1xlqmPQcHX8TJ2wjPdkrSWhcvOWZ3NkOTHi9cX2NcCkBvcMWBjXeplgB7CqXiYQ3LsvPpWkebk7XCucWGTV4U4ZllsmPXQctRsOXwZhUPRnIGohGTsBYsMXiYaB9JQIlhOZMholUkfSZERq2vHEIS77vGaG05SdMwqyWJgJmErAL1Eq3qblEmCaUJ1Yuzxj4kyRAHVQA9IVKzST3vPgKta29Vu-l7MaqMtX139M36MipqrroyC1q5Vlh7oAv5PG9c5QvKTq6Sw |
link.rule.ids | 310,311,783,787,792,793,799,4059,4060,27939,55088 |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PT8IwFG4QD-rFH2D8bQ8eHXTrurIzgYACMQESbqRru4Qow4xx0L_e124MNR68dW2WbS8v-76-vvc9hB6EYrHHI-YIwZUDHiKclk-pw91IRJQoxaWpRh6Ogt7Uf5qxWQU9lrUwWmubfKYbZmjP8tVKbkyorOkasbQw2EP7zPCKvFqrjKgQCs7klWcIHmG2syowFOLAGrOb9haMAPNpob2zvSaFIJFLwma_Pe6Mxnm4pXjij9YrFnm6x2i4fec84eS1scmihvz8Jef43486QfVdjR9-KdHrFFV0coaOvskT1pDqb7UkFN68ZalYmx5MeLG0nY1wLgK9xgYIFV4lWALwSpuLhJc2z88mau5uThYSZwYbFfhTikWaio91HU27nUm75xRdGZwFUI3MAWPBJoszX3ky9GUYKk4Fi4UMhEd1qGDTGzFY8jxXh1IZhkIFzCqhA-AmPj1H1WSV6AuESUx4bATztIZ_SQzkQfpAYIhQVHDXjS5Rzdhr_p4Lb8wLU139PX2PDnqT4WA-6I-er9Gh1Vi1sZIbVM3Sjb4F9pBFd9ZpvgAeMr2Y |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=IEEE+Sensors%2C+2005&rft.atitle=Integrated+ultrasound+imaging+systems+based+on+capacitive+micromachined+ultrasonic+transducer+arrays&rft.au=Wygant%2C+I.O.&rft.au=Yeh%2C+D.T.&rft.au=Zhuang%2C+X.&rft.au=Vaithilingam%2C+S.&rft.date=2005-01-01&rft.pub=IEEE&rft.isbn=9780780390560&rft.issn=1930-0395&rft.eissn=2168-9229&rft.spage=4+pp.&rft_id=info:doi/10.1109%2FICSENS.2005.1597796&rft.externalDocID=1597796 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1930-0395&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1930-0395&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1930-0395&client=summon |