Closed-loop eyelid reanimation system with real-time blink detection and electrochemical stimulation for facial nerve paralysis

Electrical stimulation in eyelid reanimation has been verified in previous studies as a potential treatment for facial nerve paralysis. Design challenges, including physical pain during stimulation, reducing the latency between the natural blink and the artificial blink, and patient-to-patient diffe...

Full description

Saved in:
Bibliographic Details
Published in2009 IEEE International Symposium on Circuits and Systems (ISCAS) pp. 549 - 552
Main Authors Kuanfu Chen, Tung-Chien Chen, Cockerham, K., Wentai Liu
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.05.2009
Subjects
Online AccessGet full text
ISBN1424438276
9781424438273
ISSN0271-4302
DOI10.1109/ISCAS.2009.5117807

Cover

Abstract Electrical stimulation in eyelid reanimation has been verified in previous studies as a potential treatment for facial nerve paralysis. Design challenges, including physical pain during stimulation, reducing the latency between the natural blink and the artificial blink, and patient-to-patient differences, make it difficult to build this system. In this paper, the design challenges are analyzed in detail, based on which a closed-loop electrochemical stimulation system is proposed. Using our system, real-time blink detection and electrical stimulation have been verified with FPGA and ASICs. Area of the proposed fully integrated chip, including electromyography (EMG) amplifier, blink detection processor, reduced instruction set computer (RISC), and current stimulator, is estimated to be 11.46 mm 2 in 0.35 um CMOS process.
AbstractList Electrical stimulation in eyelid reanimation has been verified in previous studies as a potential treatment for facial nerve paralysis. Design challenges, including physical pain during stimulation, reducing the latency between the natural blink and the artificial blink, and patient-to-patient differences, make it difficult to build this system. In this paper, the design challenges are analyzed in detail, based on which a closed-loop electrochemical stimulation system is proposed. Using our system, real-time blink detection and electrical stimulation have been verified with FPGA and ASICs. Area of the proposed fully integrated chip, including electromyography (EMG) amplifier, blink detection processor, reduced instruction set computer (RISC), and current stimulator, is estimated to be 11.46 mm 2 in 0.35 um CMOS process.
Author Tung-Chien Chen
Wentai Liu
Kuanfu Chen
Cockerham, K.
Author_xml – sequence: 1
  surname: Kuanfu Chen
  fullname: Kuanfu Chen
  organization: Univ. of California, Santa Cruz, CA, USA
– sequence: 2
  surname: Tung-Chien Chen
  fullname: Tung-Chien Chen
  organization: Univ. of California, Santa Cruz, CA, USA
– sequence: 3
  givenname: K.
  surname: Cockerham
  fullname: Cockerham, K.
– sequence: 4
  surname: Wentai Liu
  fullname: Wentai Liu
  organization: Univ. of California, Santa Cruz, CA, USA
BookMark eNpFkMtKw0AUhkdswbb6ArqZF0g9c8tlWYLWQsFFdV3mckJHJ0nJRCUrX91oC64O_8_HB_-Zk0nTNkjILYMlY1Dcb3blarfkAMVSMZblkF2QOZNcSpHzXF7-hyydkBnwjCVSAJ-SWQ5JKlMl4IrMY3wDGC0pn5HvMrQRXRLa9khxwOAd7VA3vta9bxsah9hjTb98f_jtQ9L7GqkJvnmnDnu0f5RuHMUwhq61B6y91YHGkfwIJ0vVdrTS1o91g90n0qPudBiij9dkWukQ8eZ8F-T18eGlfEq2z-tNudomnmWqT5SQRmUcMMtVbk3KhNbgJDBU1lVG6tTmVmlQRlUGjeEFU66yagR4AYUUC3J38npE3B-7cV837M9fFD9tl2en
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/ISCAS.2009.5117807
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE/IET Electronic Library
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 1424438284
9781424438280
EndPage 552
ExternalDocumentID 5117807
Genre orig-research
GroupedDBID -~X
29I
6IE
6IF
6IH
6IK
6IL
6IM
6IN
AAJGR
AAWTH
ABLEC
ACGFS
ADZIZ
AI.
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IJVOP
IPLJI
M43
OCL
RIE
RIL
RIO
VH1
ID FETCH-LOGICAL-i175t-534b5720e7858cb613aa0d401e5cdfb4a6c8c5a05b5fbebb2915dfc501e290943
IEDL.DBID RIE
ISBN 1424438276
9781424438273
ISSN 0271-4302
IngestDate Wed Aug 27 02:45:11 EDT 2025
IsPeerReviewed false
IsScholarly true
LCCN 80-646530
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-534b5720e7858cb613aa0d401e5cdfb4a6c8c5a05b5fbebb2915dfc501e290943
PageCount 4
ParticipantIDs ieee_primary_5117807
PublicationCentury 2000
PublicationDate 2009-May
PublicationDateYYYYMMDD 2009-05-01
PublicationDate_xml – month: 05
  year: 2009
  text: 2009-May
PublicationDecade 2000
PublicationTitle 2009 IEEE International Symposium on Circuits and Systems (ISCAS)
PublicationTitleAbbrev ISCAS
PublicationYear 2009
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0020062
ssj0000453080
Score 1.827463
Snippet Electrical stimulation in eyelid reanimation has been verified in previous studies as a potential treatment for facial nerve paralysis. Design challenges,...
SourceID ieee
SourceType Publisher
StartPage 549
SubjectTerms Computer aided instruction
Delay
Electrical stimulation
Electromyography
Eyelids
Face detection
Field programmable gate arrays
Pain
Real time systems
Reduced instruction set computing
Title Closed-loop eyelid reanimation system with real-time blink detection and electrochemical stimulation for facial nerve paralysis
URI https://ieeexplore.ieee.org/document/5117807
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1JS8NAFB5qT3pxacWdOXg07TjJdJKjFIsKFaEWeiuzvIFiTIqmB734152XpS548JYMgSSPl8z3lu97hJy7CDVclAiEcy6IQuO_OR25wAnmEglRbAEDxfH94GYa3c3ErEUu1lwYACibz6CHh2Ut3-ZmhamyvgcHMkbq-IZ3s4qrtc6neGgSMvTFOthCcmCZX5E-RgoZb0hdYczloNF6qs_Dhk3Dkv7tZHg1qXQs69v9mLtSbjujbTJuHrjqNnnqrQrdM--_tBz_-0Y7pPtF8KMP661rl7Qg2yNb37QJO-RjmOavYIM0z5cU3iBdWOoBZraouI60koCmmMfF9TTAKfVUY0GYWijKDq-MqszSetKOqaUJqP-pPNdDw6iHzNQpTNvTDHsvKUqRlyopXTIdXT8Ob4J6WkOw8BCkCEQYaSE5AxmL2GgPE5Ri1odvIIx1OlIDExuhmNDCadCaJ5fCOiP8BTzB_sZ90s7yDA4IFRBz5YA7qWWkjMdQ3h7GhdZy7iwTh6SDppwvK0GOeW3Fo7-Xj8lmVQLCLsUT0i5eVnDqkUShz0oX-gQw9sU9
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEN4QPKgXH2B8uwePFup2l7ZHQySoQEyAhBvZx2xCxJZoOejFv-5OW_ARD97aTZO2k23nm8f3DSGXlqOGixSesNZ6PNDum1Pcelb4Ng6BRwYwUOwPWt0xv5-ISYVcrbkwAJA3n0EDD_Navkn1ElNlTQcOwgip4xvO73NRsLXWGRUHTgIfd2MZbiE9MM-whC5KCny2onUFEQtbK7Wn8jxY8Wn8uHk3bN8MCyXL8oY_Jq_kjqezQ_qrRy76TZ4ay0w19PsvNcf_vtMuqX9R_Ojj2nntkQok-2T7mzphjXy05-krGG-epgsKbzCfGeogZjIr2I60EIGmmMnF9bmHc-qpwpIwNZDlPV4JlYmh5awdXYoTUPdbeS7HhlEHmqmVmLinCXZfUhQjz3VS6mTcuR21u145r8GbORCSeSLgSoTMhzASkVYOKEjpGxfAgdDGKi5bOtJC-kIJq0ApFl8LY7VwF7AYOxwPSDVJEzgkVEDEpAVmQxVyqR2KcvbQNjCGMWt8cURqaMrpopDkmJZWPP57-YJsdkf93rR3N3g4IVtFQQh7Fk9JNXtZwpnDFZk6z7fTJ7I8yIo
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2009+IEEE+International+Symposium+on+Circuits+and+Systems+%28ISCAS%29&rft.atitle=Closed-loop+eyelid+reanimation+system+with+real-time+blink+detection+and+electrochemical+stimulation+for+facial+nerve+paralysis&rft.au=Kuanfu+Chen&rft.au=Tung-Chien+Chen&rft.au=Cockerham%2C+K.&rft.au=Wentai+Liu&rft.date=2009-05-01&rft.pub=IEEE&rft.isbn=9781424438273&rft.issn=0271-4302&rft.spage=549&rft.epage=552&rft_id=info:doi/10.1109%2FISCAS.2009.5117807&rft.externalDocID=5117807
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0271-4302&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0271-4302&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0271-4302&client=summon