Detection of Partial Discharge from Stator Coil of Rotating Machine

In order to establish the method of on-line and off-line detection of partial discharge (PD) from stator coil of rotating machine, we have researched PD characteristics and PD detection method using PD sensor and model stator coil under electrical stress and developed a new PD sensor. The PD sensor...

Full description

Saved in:
Bibliographic Details
Published in2006 IEEE 8th International Conference on Properties & applications of Dielectric Materials pp. 451 - 454
Main Authors Kaneiwa, H., Murakami, N., Sakai, M., Inoue, Y.
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.06.2006
Subjects
Online AccessGet full text

Cover

Loading…
Abstract In order to establish the method of on-line and off-line detection of partial discharge (PD) from stator coil of rotating machine, we have researched PD characteristics and PD detection method using PD sensor and model stator coil under electrical stress and developed a new PD sensor. The PD sensor which was composed of an electrode and an amplifier could detect the PD pulse from a model coil. The phase resolved PD pattern by using the PD sensor showed the degradation type of insulation layer, for example, the existence of void between conductor and insulation layer within coil. The PD sensor is easily installed to the machine because it does not touch with the high voltage conductor. These results suggest that the PD sensor is useful for detection of PD from stator coils of rotating machine
AbstractList In order to establish the method of on-line and off-line detection of partial discharge (PD) from stator coil of rotating machine, we have researched PD characteristics and PD detection method using PD sensor and model stator coil under electrical stress and developed a new PD sensor. The PD sensor which was composed of an electrode and an amplifier could detect the PD pulse from a model coil. The phase resolved PD pattern by using the PD sensor showed the degradation type of insulation layer, for example, the existence of void between conductor and insulation layer within coil. The PD sensor is easily installed to the machine because it does not touch with the high voltage conductor. These results suggest that the PD sensor is useful for detection of PD from stator coils of rotating machine
Author Murakami, N.
Inoue, Y.
Sakai, M.
Kaneiwa, H.
Author_xml – sequence: 1
  givenname: H.
  surname: Kaneiwa
  fullname: Kaneiwa, H.
  organization: Toshiba Corp., Yokohama
– sequence: 2
  givenname: N.
  surname: Murakami
  fullname: Murakami, N.
  organization: Toshiba Corp., Yokohama
– sequence: 3
  givenname: M.
  surname: Sakai
  fullname: Sakai, M.
  organization: Toshiba Corp., Yokohama
– sequence: 4
  givenname: Y.
  surname: Inoue
  fullname: Inoue, Y.
  organization: Toshiba Corp., Yokohama
BookMark eNotjM1OwkAURseIiYB9Ad3MCxTvvZ3fJSmiJBCJP2sytDMwpnRM241vL0ZWJyc53zdhoza1nrF7hBki2MdVuZ0vNjMCUDMygpCu2AQFCQFowV6zzGpzcWPliI0JFeSWSN6yrO-_AKBArXUBY1Yu_OCrIaaWp8C3rhuia_gi9tXRdQfPQ5dO_H1wQ-p4mWLzV72ls8f2wDeuOsbW37Gb4JreZxdO2efy6aN8ydevz6tyvs4jajnkwhtRkQgFANVBKh8kKWUVgbLSoK5AyL0LFlGb2jhVSPSa6kJpuxf2vJuyh__f6L3ffXfx5LqfnQBFGrD4BWlrTVk
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/ICPADM.2006.284212
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Xplore
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Xplore
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Physics
EISBN 1424401909
9781424401901
EndPage 454
ExternalDocumentID 4062701
Genre orig-research
GroupedDBID 6IE
6IF
6IH
6IK
6IL
6IM
6IN
AAJGR
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IJVOP
IPLJI
OCL
RIE
RIL
RIO
ID FETCH-LOGICAL-i175t-4e84c24f3002df56ef52669620695817c045baf91178d8a6351e72d3679b494f3
IEDL.DBID RIE
ISBN 9781424401895
1424401895
ISSN 2160-9225
IngestDate Wed Jun 26 19:22:51 EDT 2024
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-4e84c24f3002df56ef52669620695817c045baf91178d8a6351e72d3679b494f3
PageCount 4
ParticipantIDs ieee_primary_4062701
PublicationCentury 2000
PublicationDate 2006-June
PublicationDateYYYYMMDD 2006-06-01
PublicationDate_xml – month: 06
  year: 2006
  text: 2006-June
PublicationDecade 2000
PublicationTitle 2006 IEEE 8th International Conference on Properties & applications of Dielectric Materials
PublicationTitleAbbrev ICPADM
PublicationYear 2006
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0003177730
ssj0000395917
Score 1.3888254
Snippet In order to establish the method of on-line and off-line detection of partial discharge (PD) from stator coil of rotating machine, we have researched PD...
SourceID ieee
SourceType Publisher
StartPage 451
SubjectTerms Coils
Conductors
Electrodes
Insulation
Partial discharges
Pulse amplifiers
Rotating machines
Sensor phenomena and characterization
Stators
Stress
Title Detection of Partial Discharge from Stator Coil of Rotating Machine
URI https://ieeexplore.ieee.org/document/4062701
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEF5qQdCL2lZ8swePbrtJ9nmU1FKFSBELvZU8NlKURNr04q93Z9PUIh48JRsSSDbDzrcz832D0G2mAYeIhFh3ZAhLckZiGUvCE5lSmQf2AKGB6FmMp-xpxmctdLflwhhjXPGZ6cOpy-VnZbqGUNmAgaYukLX2FPVrrtY2nkIDzZutB4ytX5TStRrxPUGJtnbb8LqopzRv5J6acUOooXrwGE7uh1GdqLCrtw_dKndarzjPMzpCUfPOdcHJe39dJf3065ec438_6hj1fjh-eLL1XieoZYoOOtyRJ-ygfVcemq66KByaytVsFbjM8QTMLf7Aw8XKCS0ZDCQVDLi1XOKwXHzAXS8lZPmLNxy5ek3TQ9PRw2s4Jpv2C2RhMUVFmFEs9Vke2EUzy7kwObfeXAufCs2VZ_8l40mc29VSqkzFFrl4RvpZIKROmLbPnaJ2URbmDGFI9WiexzGjChTZtPITZffDqRB-bBHGOerCxMw_a4WN-WZOLv6-fIkO6kAIxEKuULtars21hQZVcuNs4hspsKzD
link.rule.ids 310,311,786,790,795,796,802,27958,55109
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEN4QjVEvKmB8uwePFvrYR_doigSUEmIg4Ua27dYQSWugXPz17mwpEuPBU7tNm7Tbyc63M_N9g9BDIgCHsMjS7khZJEqJJbnkFo14bPPU0wcIDYRD1puQlymd1tDjlgujlDLFZ6oFpyaXn-TxGkJlbQKaukDW2td-3hYlW2sbUbE9QavNB4y1Z-TcNBtxHWZbQltuxeyyHV_QSvCpGleUGlu0-8HoqROWqQq9frvQr3Kn-YrxPd0TFFZvXZacfLTWRdSKv34JOv73s05R84flh0db_3WGaiqro-MdgcI6OjAFovGqgYKOKkzVVobzFI_A4OQCd-YrI7WkMNBUMCDXfImDfL6Au95yyPNn7zg0FZuqiSbd53HQszYNGKy5RhWFRZRPYpeknl42k5QylVLtzwVzbSao7-i_SWgkU71ecj_xpcYujuJu4jEuIiL0c-doL8szdYEwJHsETaUktg-abMJ3I1_viGPGXKkxxiVqwMTMPkuNjdlmTq7-vnyPDnvjcDAb9Iev1-ioDItAZOQG7RXLtbrVQKGI7ox9fAOF7rAZ
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2006+IEEE+8th+International+Conference+on+Properties+%26+applications+of+Dielectric+Materials&rft.atitle=Detection+of+Partial+Discharge+from+Stator+Coil+of+Rotating+Machine&rft.au=Kaneiwa%2C+H.&rft.au=Murakami%2C+N.&rft.au=Sakai%2C+M.&rft.au=Inoue%2C+Y.&rft.date=2006-06-01&rft.pub=IEEE&rft.isbn=9781424401895&rft.issn=2160-9225&rft.spage=451&rft.epage=454&rft_id=info:doi/10.1109%2FICPADM.2006.284212&rft.externalDocID=4062701
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2160-9225&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2160-9225&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2160-9225&client=summon